246721-YTG-C-0606
28
Unitary Products Group
NOTE:
Electric heaters are rated at nominal voltage. Use
this table to determine the electric heat capacity for
heaters supplied at lower voltages.
TABLE 15: ELECTRICAL DATA DR150 W/O PWRD CONVENIENCE OUTLET
RLA
LRA
FLA
3
5
3
5
3
5
3
5
3
5
ea.
ea.
ea.
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
None
--
--
61.9
67.1
67.4
72.6
80
80
80
90
2TP04521825
13.5
37.5
61.9
67.1
67.4
73.8
80
80
80
90
2TP04522425
18.0
50.0
76.1
82.6
83.0
89.5
80
90
90
90
2TP04523625
25.5
70.8
102.1
108.6
109.0
115.5
110
110
110
125
2TP04525425 40.6
112.7
154.5
161.0
161.4
167.9
175
175
175
175
None
--
--
61.9
67.1
67.4
72.6
80
80
80
90
2TP04521825
18.0
43.3
67.8
74.3
74.6
81.1
80
80
80
90
2TP04522425
24.0
57.7
85.8
92.3
92.7
99.2
90
100
100
100
2TP04523625
34.0
81.8
115.9
122.4
122.7
129.2
125
125
125
150
2TP04525425 54.0
129.9
143.5
150.0
150.4
156.9
175
175
175
175
None
--
--
27.4
30.2
29.6
32.4
35
35
35
40
2TP04521846
18
22.6
33.7
37.2
36.4
39.9
35
40
40
40
2TP04522446
24
30.1
42.7
46.2
45.5
49
45
50
50
50
2TP04523646
34
42.7
57.7
61.2
60.5
64
60
70
70
70
2TP04525446
54
67.8
71.6
75.1
74.3
77.8
80
90
80
90
None
--
--
22.5
24.4
24.3
26.2
25
30
30
30
2TP04521858
18
18.1
26.8
29.2
29
31.4
30
30
30
35
2TP04522458
24
24.1
34
36.4
36.2
38.6
35
40
40
40
2TP04523658
34
34.1
46
48.4
48.3
50.6
50
50
50
60
2TP04525458
54
54.2
57.1
59.5
59.3
61.7
70
70
70
70
*
Voltage
Compressors
OD Fan
Motors
Supply Blower
Motor FLA
Pwr Exh
Motor
Pwr
Conv
Outlet
Electric Heater
Model No.
Actual
KW
Heater
Amps
Min. Circuit
Ampacity
(Amps)
MCA w/Power
Exhaust
(Amps)
Max Fuse* Size
(Amps)
Max Fuse Size
w/Power
Exhaust
(Amps)
FLA
FLA
208
20.0
146.0
1.5
10.9
16.1
5.5
0.0
230
20.0
146.0
1.5
10.9
16.1
5.5
0.0
460
8.4
73.0
0.8
5.3
8.1
2.2
0.0
575
7.1
60.0
0.6
4.1
6.0
1.8
0.0
Maximum HACR breaker of the same AMP size is applicable.
TABLE 16: ELECTRICAL DATA DR150 W/PWRD CONVENIENCE OUTLET
RLA
LRA
FLA
3
5
3
5
3
5
3
5
3
5
ea.
ea.
ea.
HP
HP
HP
HP
HP
HP
HP
HP
HP
HP
None
--
--
71.9
77.1
77.4
82.6
90
90
90
100
2TP04521825
13.5
37.5
73.0
79.5
79.8
86.3
90
90
90
100
2TP04522425
18.0
50.0
88.6
95.1
95.5
102.0
90
100
100
110
2TP04523625
25.5
70.8
114.6
121.1
121.5
128.0
125
125
125
150
2TP04525425 40.6
112.7
167.0
173.5
173.9
180.4
175
175
175
200
None
--
--
71.9
77.1
77.4
82.6
90
90
90
100
2TP04521825
18.0
43.3
80.3
86.8
87.1
93.6
90
90
90
100
2TP04522425
24.0
57.7
98.3
104.8
105.2
111.7
100
110
110
125
2TP04523625
34.0
81.8
128.4
134.9
135.2
141.7
150
150
150
150
2TP04525425 54.0
129.9
156.0
162.5
162.9
169.4
175
175
175
175
None
--
--
32.4
35.2
34.6
37.4
40
40
40
45
2TP04521846
18
22.6
39.9
43.4
42.7
46.2
40
45
45
50
2TP04522446
24
30.1
49
52.5
51.7
55.2
50
60
60
60
2TP04523646
34
42.7
64
67.5
66.7
70.2
70
70
70
80
2TP04525446
54
67.8
77.8
81.3
80.6
84.1
90
90
90
90
None
--
--
26.5
28.4
28.3
30.2
30
35
35
35
2TP04521858
18
18.1
31.8
34.2
34
36.4
35
35
35
40
2TP04522458
24
24.1
39
41.4
41.2
43.6
40
45
45
45
2TP04523658
34
34.1
51
53.4
53.3
55.6
60
60
60
60
2TP04525458
54
54.2
62.1
64.5
64.3
66.7
70
70
70
70
*
Voltage
Compressors
OD Fan
Motors
Supply Blower
Motor FLA
Pwr Exh
Motor
Pwr
Conv
Outlet
Electric Heater
Model No.
Actual
KW
Heater
Amps
Min. Circuit
Ampacity
(Amps)
MCA w/Power
Exhaust
(Amps)
Max Fuse* Size
(Amps)
Max Fuse Size
w/Power
Exhaust
(Amps)
FLA
FLA
208
20.0
146.0
1.5
10.9
16.1
5.5
10.0
230
20.0
146.0
1.5
10.9
16.1
5.5
10.0
5.0
460
8.4
73.0
0.8
0.6
5.3
8.1
2.2
Maximum HACR breaker of the same AMP size is applicable.
4.1
6.0
1.8
4.0
575
7.1
60.0
TABLE 17: ELECTRIC HEAT MULTIPLIERS
VOLTAGE
kW Cap. Multiplier
NOMINAL
RATING
240
208
0.75
230
0.92
480
460
0.92
600
575
0.92
Summary of Contents for PREDATOR MagnaDRY DR090
Page 11: ...246721 YTG C 0606 Unitary Products Group 11 FIGURE 4 DR090 120 REHEAT CONTROLS ...
Page 12: ...246721 YTG C 0606 12 Unitary Products Group FIGURE 5 DR150 REHEAT CONTROLS ...
Page 60: ...246721 YTG C 0606 60 Unitary Products Group FIGURE 41 DR090 AND 120 REHEAT WIRING DIAGRAM ...
Page 61: ...246721 YTG C 0606 Unitary Products Group 61 FIGURE 42 DR150 REHEAT WIRING DIAGRAM ...