246721-YTG-C-0606
18
Unitary Products Group
TABLE 6: COOLING CAPACITY DR090 UNIT (ALTERNATE REHEAT MODE)
86
83
80
77
74
71
68
86
83
80
77
74
71
68
72
44
6.6
10
3
-
-
-
-
-
39
6.9
10
4
-
-
-
-
-
67
39
6.3
17
11
4
-
-
-
-
34
6.6
14
8
2
-
-
-
-
62
35
6.0
24
18
11
5
-
-
-
29
6.2
19
12
6
-
-
-
-
57
37
5.7
28
21
15
8
2
-
-
33
5.9
20
14
8
1
-
-
-
72
45
6.6
9
2
-
-
-
-
-
40
6.9
8
-
-
-
-
-
-
67
41
6.3
23
15
8
-
-
-
-
35
6.6
20
12
5
-
-
-
-
62
36
6.1
31
28
21
13
5
-
-
30
6.3
25
22
17
9
2
-
-
57
39
5.7
34
31
27
20
12
4
-
35
6.0
28
25
21
14
6
-
-
72
47
6.6
9
-
-
-
-
-
-
41
6.9
5
-
-
-
-
-
-
67
42
6.3
29
20
11
2
-
-
-
37
6.7
25
16
8
-
-
-
-
62
37
6.1
37
37
30
21
12
4
-
31
6.3
31
31
27
19
10
1
-
57
40
5.7
40
40
39
31
22
13
4
36
6.0
36
36
35
27
18
9
-
72
48
6.7
10
-
-
-
-
-
-
42
7.0
4
-
-
-
-
-
-
67
43
6.3
34
24
14
4
-
-
-
37
6.7
30
20
10
-
-
-
-
62
38
6.1
38
38
35
25
15
5
-
32
6.4
32
32
30
20
10
-
-
57
41
5.7
41
41
41
31
21
11
1
37
6.0
37
37
36
26
16
6
-
72
50
6.7
10
-
-
-
-
-
-
43
7.0
3
-
-
-
-
-
-
67
44
6.4
38
27
16
5
-
-
-
38
6.7
35
23
12
1
-
-
-
62
40
6.1
40
40
40
28
17
6
-
33
6.4
33
33
33
22
10
-
-
57
42
5.7
42
42
42
31
20
9
-
37
6.0
37
37
37
26
15
4
-
72
7.2
20
17
13
7
-
-
-
29
7.5
29
29
29
22
16
10
3
67
29
34
6.8
12
6
-
-
-
-
-
25
7.1
10
3
-
-
-
-
-
62
25
6.5
-
-
-
-
-
-
-
21
6.8
-
-
-
-
-
-
-
57
29
6.2
-
-
-
-
-
-
-
25
6.5
-
-
-
-
-
-
-
72
35
7.2
11
5
-
-
-
-
-
30
7.5
14
10
5
-
-
-
-
67
30
6.9
17
10
2
-
-
-
-
26
7.1
15
7
-
-
-
-
-
62
26
6.5
13
10
5
-
-
-
-
22
6.8
2
-
-
-
-
-
-
57
30
6.2
13
10
7
-
-
-
-
26
6.5
-
-
-
-
-
-
-
72
36
7.2
2
-
-
-
-
-
-
31
7.5
-
-
-
-
-
-
-
67
31
6.9
22
14
5
-
-
-
-
26
7.1
20
11
2
-
-
-
-
62
27
6.6
27
27
24
15
6
-
-
23
6.8
23
23
20
11
2
-
-
57
31
6.3
31
31
31
22
14
5
-
27
6.6
27
27
27
18
9
1
-
72
36
7.3
-
-
-
-
-
-
-
30
7.6
-
-
-
-
-
-
-
67
32
6.9
26
17
7
-
-
-
-
26
7.2
22
13
3
-
-
-
-
62
27
6.6
27
27
25
15
5
-
-
22
6.9
22
22
21
11
1
-
-
57
31
6.3
31
31
31
21
11
1
-
26
6.6
26
26
26
16
6
-
-
72
37
7.3
-
-
-
-
-
-
-
30
7.6
-
-
-
-
-
-
-
67
32
7.0
30
19
8
-
-
-
-
25
7.3
25
15
4
-
-
-
-
62
27
6.7
27
27
27
16
5
-
-
22
6.9
22
22
22
10
-
-
-
57
32
6.4
32
32
32
20
9
-
-
26
6.7
26
26
26
15
3
-
-
72
25
7.7
25
25
25
25
25
25
19
67
20
7.3
7
1
-
-
-
-
-
62
17
7.0
-
-
-
-
-
-
-
* -
57
21
6.8
-
-
-
-
-
-
-
72
25
7.8
18
15
12
4
-
-
-
67
21
7.4
12
4
-
-
-
-
-
62
18
7.1
-
-
-
-
-
-
-
† -
57
22
6.8
-
-
-
-
-
-
-
72
26
7.8
-
-
-
-
-
-
-
67
21
7.4
17
8
-
-
-
-
-
62
18
7.1
18
18
16
7
-
-
-
-
57
22
6.8
22
22
22
14
5
-
-
72
24
7.9
-
-
-
-
-
-
-
67
20
7.5
19
10
-
-
-
-
-
62
17
7.2
17
17
16
6
-
-
-
57
21
6.9
21
21
21
11
1
-
-
72
23
7.9
-
-
-
-
-
-
-
67
19
7.5
19
11
-
-
-
-
-
62
16
7.2
16
16
16
5
-
-
-
57
20
7.0
20
20
20
9
-
-
-
These capacities are gross ratings. For net capacity,
deduct air blower motor, MBh = 3.415 x kW. Refer to the
appropriate Blower Performance Table for the kW of the
supply air blower motor.
These ratings include the condenser fan motors (total 1
kW) and the compressor motors but not the supply air
blower motor.
No sensible cooling capacity.
3000
Sensible Capacity (MBH)
Tot.
Input
†
(kW)
Return Dry Bulb (°F)
Return Dry Bulb (°F)
Temperature of Air on Condenser Coil 105°F
2250
2625
3000
3750
Temperature of Air on Condenser Coil 125°F
3375
3750
2250
2625
3375
Temperature of Air on Condenser Coil 115°F
2250
2625
3000
3375
3750
Air On Evap. Coil
Temperature of Air on Condenser Coil 85°F
Temperature of Air on Condenser Coil 95°F
CFM
WB (°F)
Total
Cap.*
(MBH)
Tot.
Input
†
(kW)
Sensible Capacity (MBH)
Total
Cap.*
(MBH)
Summary of Contents for PREDATOR MagnaDRY DR090
Page 11: ...246721 YTG C 0606 Unitary Products Group 11 FIGURE 4 DR090 120 REHEAT CONTROLS ...
Page 12: ...246721 YTG C 0606 12 Unitary Products Group FIGURE 5 DR150 REHEAT CONTROLS ...
Page 60: ...246721 YTG C 0606 60 Unitary Products Group FIGURE 41 DR090 AND 120 REHEAT WIRING DIAGRAM ...
Page 61: ...246721 YTG C 0606 Unitary Products Group 61 FIGURE 42 DR150 REHEAT WIRING DIAGRAM ...