5126744-UIM-D-1015
20
Johnson Controls Unitary Products
FIGURE 12:
Connection Wiring Diagram - 3.5 to 5 Ton Models
WITH SCROLL COMPRESSOR
208/230-1-60
CONNECTION WIRING DIAGRAM
COOLING UNIT WITH OR
WITHOUT ELECTRIC HEAT
CAUTION - OPEN ALL DISCONNECTS
BEFORE SERVICING THIS UNIT
1. ALL FIELD WIRING TO BE ACCOMPLISHED FOLLOWING CITY,
LOCAL AND/OR NATIONAL CODES IN EFFECT AT THE TIME OF
INSTALLATION OF THE UNIT.
2. CAUTION : LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN
SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER
AND DANGEROUS OPERATION. IF ANY OF THE WIRING, AS SUPPLIED
WITH THE UNIT, MUST BE REMOVED, IT MUST BE REPLACED WITH
TYPE 105 C. 600 VOLT WIRE OR EQUIVALENT CLEARLY RENUMBERED
FOR IDENTIFICATION. VERIFY PROPER OPERATION AFTER SERVICING.
3. FACTORY WIRED FOR 230 VOLT SUPPLY POWER. FOR 208 VOLT,
MOVE BLACK WIRES FROM THE 230 TO THE 208 VOLT TAP ON THE
TRANSFORMER.
NOTES:
BLU 29
RED 30
WHT 25
GRN 24
Y
R
G
C
THERMOSTAT
USE COPPER
CONDUCTORS
ONLY
YEL 20
GRN 4
(LOW)
(LOW/MED)
(MED)
(MED/HIGH)
(HIGH)
C
L
G
N
1
2
3
4
5
1
2
3
4
HI PRESS
LOW
VOLTAGE
BOX
W1
(COOLING SPEED)
(HEATING SPEED)
(CONTINUOUS FAN)
BLK
BRN
RED
BLK/WHT 12
BRN/WHT 13
PUR 1
RED 9
OD FAN
MOTOR
POWER SUPPLY
208/230-1-60
BLK 6
BLK 5
COM
PRIMARY
24V SEC
40 VA
208V
230V
COMPR
C
S
R
L1
T1
T2
L2
FAN
HERM
C
DUAL
CAPACITOR
RED 7
GRN
BLU 22
CONTACTOR
COIL
SINGLE POLE
CONTACTOR
PUR 2
YEL 18
GRN 21
LINE VOLTAGE
FIELD INSTALLED POWER
LOW VOLTAGE
FIELD INSTALLED CONTROL
5
4
3
2
6
1
BLK
BRN
GRN 10
RED
BLOWER
MOTOR
SHARED TAP
SEE NOTE 7
XFMR
BLU 23
5
4
3
2
6
1
BLU 27
YEL 19
3A FUSE
WHT 32
WHT 26
BRN 28
W2
FEMALE CONNECTOR
FOR 6HK HEATER KIT
OR SEQUENCER
SECOND STAGE RELAY
OR SEQUENCER
FIRST STAGE RELAY
24V COMMON
FOR WIRING WITH ELECTRIC HEATERS
SEE SCHEMATIC ON HEATER ACCESSORY.
RED 33
INDOOR BLOWER 60 SECOND OFF
DELAY FOR BOTH HEAT & COOL MODES.
GND
LUG
CRANKCASE
HEATER
GRN
TEMPERATURE
SWITCH
OPTIONAL CRANKCASE HEATER
BLK
BLK
BLK
4. MOTORS ARE INHERENTLY PROTECTED.
5. SEE UNIT NAMEPLATE FOR MAXIMUM FUSE AND/OR CIRCUIT
BREAKER SIZE AND MINIMUM CIRCUIT AMPACITY.
6. BLOWER MOTOR SPEED CONNECTIONS SHOWN ARE TYPICAL,
BUT MAY VARY BY MODEL AND APPLICATION. SEE INSTALLATION
MANUAL FOR PROPER SPEED TAP INFORMATION FOR EACH
APPLICATION TO OBTAIN APPROX. 400 CFM/TON IN COOLING.