5126744-UIM-D-1015
12
Johnson Controls Unitary Products
FIGURE 8:
Single Point Wiring Kits
NOTE:
For single circuit heater kits,
remove the wires for the second
circuit from the single-point block.
(Mount with 4 self tapping
screws as shown.)
A0352-003
FOR USE WITH THE FOLLOWING HEARTER KITS
Heater Kit No.
kW 208/240
Volts
Amps 208/240
6HK16500206
1.8/2.4
280/240
8.7/10.0
6HK16500506
3.6/4.8
280/240
17.3/20.0
6HK16500806
5.76/7.68
280/240
27.7/32.0
6HK16501006
7.2/9.6
280/240
34.6/40.0
6HK16501306
9.36/12.48
280/240
45.0/52.0
6HK16501506
10.8/14.4
280/240
51.9/60.0
6HK16501806
12.96/17.28
280/240
62.3/72.0
6HK16502006
14.4/19.2
280/240
89.2/80.0
TO L1 on HEAT KIT BREAKER(S)
TO L2 on HEAT KIT BREAKER(S)
TO HEAT KIT GROUND LUG
Single Point Kit P/N
Unit Model Number
Breaker Size
Heat Kit
S1-2SPWK008
PCE4A24
20 Amp
up to 13 kW
S1-2SPWK006
PCE4A30
25 Amp
up to 15 kW
S1-2SPWK001
PCE4A36
30 Amp
up to 15 kW
S1-2SPWK006
PHE4A24
25 Amp
up to 13 kW
S1-2SPWK002
PHE4A30
35 Amp
up to 15 kW
S1-2SPWK007
PHE4B36
40 Amp
up to 15 kW
S1-2SPWK003
PCE4A42
45 Amp
up to 20 kW
S1-2SPWK003
PHE4B42
45 Amp
up to 20 kW
S1-2SPWK004
PCE4B48
50 Amp
up to 20 kW
S1-2SPWK004
PHE4B48
50 Amp
up to 20 kW
S1-2SPWK005
PCE4B60
60 Amp
up to 20 kW
S1-2SPWK005
PHE4B60
60 Amp
up to 20 kW