• By the
keys, select one of 21
programs available in this menu item.
• After pressing the
key, the cursor
starts to flash.
• By the
keys, mark
the switch-on or -off time you want to
change.
• After pressing the
key the selected
time display starts to flash.
• By the
keys, set the required
switch -on or -off time.
• By pressing the
key confirm the
time setting.
• By the
keys,
mark the days, during which this time
program shoud be active or inactive.
X
… active
… inactive
• After pressing the
ESC
key, shut the
Time program menu issue.
• If you did any changes in setting, the
“Save?” question will appear on the
display
If you wish to save the changes, press
the
key.
PARAMETERS OVERVIEW :
REGULATION AND WARNING DEScRIPTION
Time program - Legionellas
… re-adjustable parameters
Warning
If there is still no day selected, by
X
symbol, for the
Time program, you must to set one prior to switch-on
or -off, at least.
Warning
For this operation execution an electric heating rod
must be installed into the service water tank!
IMPORTANT!
With normal use, and regular hot water consumption,
no measures against Legionellas are necessary
to take because the service water tank is heated
regularly!
By this Time program activation, however, you may
carry out a cyclic bacteria removal from the service
water tank.
Highlight one day per weak for this purpose, in
compliancewith the description mentioned above, by
X symbol. Any special time setting is not necessary,
as the process stops automatically, as soon as the
temperature, in the tank, reaches the value of 70°C.