background image

036-21359-001-B-0302

Unitary Products Group

3

FIELD-INSTALLED ACCESSORIES

SINGLE INPUT ELECTRONIC ENTHALPY
ECONOMIZERS

Includes a slide-in/plug-in damper assembly with fully
modulating spring-return monitor actuator capable of
introducing up to 100% outdoor air with nominal 1%
leakage type dampers.

The enthalpy system contains one sensor that
monitors the outdoor air and determines when the air is
cool enough and dry enough to provide “free” cooling.

The rainhood is painted to match the basic unit and
must be field-assembled before installing.

Power exhaust is not available as a field installed
option.

DUAL INPUT ELECTRONIC ENTHALPY
ECONOMIZERS

Includes a slide-in / plug-in damper assembly with fully
modulating spring-return monitor actuator capable of
introducing up to 100% outdoor air with nominal 1%
leakage type dampers.

This enthalpy system contains one sensor that moni-
tors the outdoor air and one sensor that monitors the
return air. The logic module compares these two val-
ues and modulates the dampers providing the maxi-
mum efficiency of economizer system.

The rainhood is painted to match the basic unit and
must be field-assembled before installing.

Power exhaust is not available as

a field installed

option.

MOTORIZED OUTDOOR AIR INTAKE DAMPER

Includes a slide-in/plug-in damper assembly with a
2-position, spring return motor actuator which opens to
some pre-set position whenever the supply air blower
is operating and will drive fully closed when the blower
unit shuts down.

The rain hood is painted to match the basic unit and
must be field assembled before installing.

Power exhaust is not available as a field installed
option.

ROOF CURBS

Fourteen inch high roof curbs provide a water-tight seal
between the unit and the finished roof. These full
perimeter curbs meet the requirements of the National
Roofing Contractors Association (NRCA) and are
shipped knocked-down for field assembly. They're
designed to fit inside the base rails of the unit and
include both a wood nailing strip and duct hanger sup-
ports.

ANTI-RECYCLE TIMERS

Two solid state timers prevent the compressors from
short-cycling. Once a compressor is de-energized, it
will remain de-energized for approximately five min-
utes.

HIGH ALTITUDE NATURAL GAS

Burner orifices and pilot orifices are provided for proper
furnace operation at altitudes up to 6,000 feet.

PROPANE

Burner orifices, pilot orifices and gas valve parts are
provided to convert a natural gas furnace to propane.

HIGH ALTITUDE PROPANE

Burner orifices and pilot orifices are provided for proper
furnace operation at altitudes up to 6,000 feet. This
accessory supplements the basic propane conversion
kit.

SIDE DUCT FLANGES

One inch flanges replace the supply and return air pan-
els on the rear of the unit to accommodate horizontal
duct connections. These flanges can also be used indi-
vidually for bottom supply/horizontal return or horizon-
tal supply/bottom return. They cannot be used on units
with power exhaust.

BAROMETRIC RELIEF DAMPER

This damper accessory can be used to relieve internal
air pressure on units with an economizer but no power
exhaust. This accessory includes a rain hood, a bird
screen and a fully assembled damper. With bottom
duct connections, the damper should be mounted over
the opening in the return air panel. With horizontal
ductwork, the accessory should be mounted on the
return air duct.

ECONOMIZER / POWER EXHAUST RAIN HOODS

A rain hood accessory must be used on units with an
economizer, a motorized damper, or a combined econ-
omizer with power exhaust option. These accessories
include all the hood panels, the necessary components
and hardware for field assembly.

HIGH SPEED DRIVE

A smaller blower pulley and a shorter belt increase the
speed of the supply air blower for applications with a
higher CFM and/or static pressure requirement.

LOW AMBIENT CONTROLS TO 0°F

An autotransformer and a thermostat maintain stable
system operation by reducing the speed of the con-
denser fan motor at low outdoor temperatures. The kit

Summary of Contents for D2CE

Page 1: ...de an exceptionally durable finish with the 750 hour salt spray process per ASTM B117 test standard All models including those with an economizer are suit able for either bottom or horizontal duct con...

Page 2: ...knockout in the wiring panel on the front of the unit All internal factory wiring is color coded and numbered for ease in servicing and troubleshooting FACTORY INSTALLED OPTIONS ECONOMIZERS Interlock...

Page 3: ...assembly They re designed to fit inside the base rails of the unit and include both a wood nailing strip and duct hanger sup ports ANTI RECYCLE TIMERS Two solid state timers prevent the compressors fr...

Page 4: ...w e r S u p p l y w i t h E l e c t r i c H e a t E L E C T R I C E L E C T R I C U N I T S E L E C T R I C H E A T E R L O C A T I O N O P T I O N A L E L E C T R I C E L E C T R I C U N I T S I 2 0...

Page 5: ...er Coil 105 F 115 F Total Cap 1 MBH Power Input2 KW SensibleCapacity1 MBH Total Cap 1 MBH Power Input2 KW SensibleCapacity1 MBH CFM WB F En ter ing Dry Bulb F En ter ing Dry Bulb F 86 83 80 77 74 71 6...

Page 6: ...resistances have been deducted from the total static pressure of the blower FACTORY SETTING 7500 CFM 8750 CFM 10000 CFM 11250 CFM 12500 CFM STANDARD DRIVE ACCESSORY DRIVE DCE300 BOT TOM DUCT CON NEC T...

Page 7: ...18 KW 25 36 KW 30 54 KW 35 72 KW 40 Accesso ries Roof Curb 185 BarometricDamper 45 Economizer MotorizedDamper Rain Hood 55 Economizer PowerExhaustRain Hood 90 Wood Skid 220 OPERATING WEIGHTS ELECTRICA...

Page 8: ...140 1365 1B5V94 9 7 9 5 1 7 16 5VX840 84 0 1 1All mo tors have a nomi nal speed of 1800 RPM a 1 15 serv ice fac tor and a solid base They can op er ate to the limit of their serv ice fac tor be cause...

Page 9: ...n o t r e q u i r e d o n u n i t s w i t h a s i n g l e s t a g e e l e c t r i c h e a t e r C O O L I N G H E A T I N G E L E C T R O N I C T H E R M O S T A T T H E R M O S T A T 1 T E R M I N A...

Page 10: ...H RAILS Shown separately to illustrate Bottom Duct openings Power and Gas Piping Connection locations 12 1 2 9 1 4 8 1 8 9 3 4 3 3 4 B POWER WIRING ENTRY A CONTROL WIRING ENTRY 92 CONDENSER COILS OPTI...

Page 11: ...he rear of the unit SUPPLY AIR RETURN AIR OUTDOOR AIR 5 1 8 18 5 8 27 3 4 29 5 8 15 TON 39 5 8 20 TON 40 1 2 OUTDOOR AIR COMPARTMENT ACCESS FILTER ACCESS 1 NPT FEMALE COND DRAIN CONNECTION DOT PLUG Fo...

Page 12: ...ized motor 4 Point Loads 6 Point Loads DCE UNIT 4 POINT LOADS LBS TOTAL A B C D 300 2 890 487 619 646 508 DCE UNIT 6 POINT LOADS LBS TOTAL A B C D E F 300 2 890 415 471 528 551 492 433 DCG UNIT 4 POIN...

Page 13: ...036 21359 001 B 0302 Unitary Products Group 13 BASE RAIL 3 56 3 69...

Page 14: ...036 21359 001 B 0302 14 Unitary Products Group...

Page 15: ...measuring ports shall be pro vided on the outside of the cabinet to allow accu rate air measurements of evaporator fan performance without removing panels or creating air by pass of the coils 7 Conden...

Page 16: ...spark ignition redundant main gas valve Ventor wheel shall be constructed of stainless steel for corrosion resistance 2 The heat exchanger shall be of the tubular type constructed of T1 40 aluminized...

Page 17: ...e outdoor and return air damper assembly to take in the design CFM of outdoor air to meet the mini mum ventilation requirement of the conditioned space during normal operation During economizer operat...

Page 18: ...pulley and belt for higher CFM and or static pressure require ments 9 WOOD SKID Allows unit to be handled with 90 forks 10 ECONOMIZER MOTORIZED DAMPER RAIN HOOD DCE CG300 only Contains all hood panels...

Page 19: ...036 21359 001 B 0302 Unitary Products Group 19...

Page 20: ...036 21359 001 B 0302 20 Unitary Products Group...

Page 21: ...036 21359 001 B 0302 Unitary Products Group 21...

Page 22: ...036 21359 001 B 0302 22 Unitary Products Group...

Page 23: ...036 21359 001 B 0302 Unitary Products Group 23...

Page 24: ...ge without notice Printed in U S A CD 6 21359 036 21359 001 B 0302 Copyright by Unitary Products Group 2002 All rights reserved Supersedes 036 21359 001 A 0302 Unitary 5005 Norman Products York OK Gro...

Reviews: