Unitary Products Group

also includes a 1-phase motor to replace the unit's
standard 3-phase condenser fan motor. Standard units
can operate down to 45°F.

COIL GUARD KIT

Provides coil guard and fastners.

Note: All gas units are two-stage heating. First stage is 50% of total.

All models are 80% Steady State Efficiency (S.S.E.).

NOTE: These values have been derived using a model of sound propagation,
measuring the indoor ambient sound levels ten feet from the source. The dBA
values provided are for reference only. Calculation of dBA values cover matters
of system design and application. This constitutes an exception to any specifi-

cation or guarantee requiring a dBA value or sound data in any other form than
sound power level ratings.

CAPACITY RATINGS - (ARI 360)

*

MODEL

MBH

EER

IPLV

MODEL

MBH

EER

IPLV

COOLING WITH GAS HEAT

COOLING WITH ELECTRIC HEAT

D2CG300N240

290

8.5

8.3

D2CE300E018

290

8.5

8.6

D2CG300N320

290

8.5

8.3

D2CE300E036

290

8.5

8.6

COOLING ONLY

D2CE300E054

287

8.5

8.2

D2CE300

290

8.5

8.7

D2CE300E072

284

8.5

8.2

*.

Outside the scope of ARI Standard 340/360.
EER=Energy Efficiency Rating at full load-the cooling capacity in Btu’s per hour (Btuh) divided by the power input in watts, expressed in Btuh per
watt (Btuh/watt).
IPLV - Integrated part load value.

NOTE: All cooling is three stage.

L O N G   L A S T I N G

P O W D E R   P A I N T   F I N I S H

F U L L   P E R I M E T E R   1 4   G U A G E   B A S E

R A I L S   W I T H   L I F T I N G   H O L E S

N P T

T E R M I N A L   B L O C K

( F o r   S i n g l e   P o i n t   P o w e r   S u p p l y

w i t h   E l e c t r i c   H e a t )

E L E C T R I C / E L E C T R I C   U N I T S

E L E C T R I C   H E A T E R   L O C A T I O N

( O P T I O N A L   E L E C T R I C / E L E C T R I C   U N I T S )

I

2 0   G A U G E   A L U M I N I Z E D   S T E E L

T U B U L A R   H E A T   E X C H A N G E R S

E C O N O M I Z E R   H O O D

2 "   D I S P O S A B L E

F I L T E R S

O U T D O O R   A I R   O P E N I N G

F O R   S L I D E - I N / P L U G - I N

I N T E R N A L   E C O N O M I Z E R   ( O P T I O N )

S I D E   A N D   B O T T O M

S U P P L Y   &   R E T U R N   A I R

D U C T   O P E N I N G S   ( S I D E   X   S I D E )

1 "   N P T I

C O N D E N S A T E   D R A I N

B E L T - D R I V E

B L O W E R   M O T O R

P O W E R   V E N T O R   M O T O R

W I T H   P O S T   P U R G E   C Y C L E

H O L E   F O R   B O T T O M

G A S   S U P P L Y   E N T R Y

K N O C K O U T S   F O R   S I D E

G A S   S U P P L Y   E N T R Y

B O T T O M   P O W E R   &   C O N T R O L

W I R I N G   E N T R Y

K N O C K O U T   F O R

S I D E   P O W E R   W I R I N G   E N T R Y   S I D E

K N O C K O U T   F O R

S I D E   C O N T R O L   W I R I N G   E N T R Y

E L E C T R I C A L   D I S C O N N E C T

M O U N T I N G   L O C A T I O N

( F i e l d   i n s t a l l e d )

L O W   V O L T A G E   R E L A Y   B O A R D

A N D   T E R M I A N L   S T R I P

C O P P E R   T U B E / A L U M I N U M   F I N

C O N D E N S E R   C O I L S  

H I G H   E F F I C I E N C Y   S C R O L L   C O M P R E S S O R S

GAS HEAT RATINGS

MODEL

MBH Input

MBH Output

Stage

1&2

Stage 1

Stage

1&2

Stage 1

D2CG300N240

300

150

240

120

D2CG300N320

400

200

320

160

Unit

Size

CFM

)

ESP

Blower

Sound Power (db 10-

12

Watts)

Octave Band Centerline Frequency (Hz)

SWL

db(A)

@ 10 Ft.

*

IWG

RPM

BHP

63

125 250 500 1,000

2,000

4,000

8,000 db(A)

300

10,000 1.30 1,160 12.5 108 108

98

91

93

86

81

76

98

65

*.

At a distance of 10 ft.from the blower.

Summary of Contents for D2CE

Page 1: ...de an exceptionally durable finish with the 750 hour salt spray process per ASTM B117 test standard All models including those with an economizer are suit able for either bottom or horizontal duct con...

Page 2: ...knockout in the wiring panel on the front of the unit All internal factory wiring is color coded and numbered for ease in servicing and troubleshooting FACTORY INSTALLED OPTIONS ECONOMIZERS Interlock...

Page 3: ...assembly They re designed to fit inside the base rails of the unit and include both a wood nailing strip and duct hanger sup ports ANTI RECYCLE TIMERS Two solid state timers prevent the compressors fr...

Page 4: ...w e r S u p p l y w i t h E l e c t r i c H e a t E L E C T R I C E L E C T R I C U N I T S E L E C T R I C H E A T E R L O C A T I O N O P T I O N A L E L E C T R I C E L E C T R I C U N I T S I 2 0...

Page 5: ...er Coil 105 F 115 F Total Cap 1 MBH Power Input2 KW SensibleCapacity1 MBH Total Cap 1 MBH Power Input2 KW SensibleCapacity1 MBH CFM WB F En ter ing Dry Bulb F En ter ing Dry Bulb F 86 83 80 77 74 71 6...

Page 6: ...resistances have been deducted from the total static pressure of the blower FACTORY SETTING 7500 CFM 8750 CFM 10000 CFM 11250 CFM 12500 CFM STANDARD DRIVE ACCESSORY DRIVE DCE300 BOT TOM DUCT CON NEC T...

Page 7: ...18 KW 25 36 KW 30 54 KW 35 72 KW 40 Accesso ries Roof Curb 185 BarometricDamper 45 Economizer MotorizedDamper Rain Hood 55 Economizer PowerExhaustRain Hood 90 Wood Skid 220 OPERATING WEIGHTS ELECTRICA...

Page 8: ...140 1365 1B5V94 9 7 9 5 1 7 16 5VX840 84 0 1 1All mo tors have a nomi nal speed of 1800 RPM a 1 15 serv ice fac tor and a solid base They can op er ate to the limit of their serv ice fac tor be cause...

Page 9: ...n o t r e q u i r e d o n u n i t s w i t h a s i n g l e s t a g e e l e c t r i c h e a t e r C O O L I N G H E A T I N G E L E C T R O N I C T H E R M O S T A T T H E R M O S T A T 1 T E R M I N A...

Page 10: ...H RAILS Shown separately to illustrate Bottom Duct openings Power and Gas Piping Connection locations 12 1 2 9 1 4 8 1 8 9 3 4 3 3 4 B POWER WIRING ENTRY A CONTROL WIRING ENTRY 92 CONDENSER COILS OPTI...

Page 11: ...he rear of the unit SUPPLY AIR RETURN AIR OUTDOOR AIR 5 1 8 18 5 8 27 3 4 29 5 8 15 TON 39 5 8 20 TON 40 1 2 OUTDOOR AIR COMPARTMENT ACCESS FILTER ACCESS 1 NPT FEMALE COND DRAIN CONNECTION DOT PLUG Fo...

Page 12: ...ized motor 4 Point Loads 6 Point Loads DCE UNIT 4 POINT LOADS LBS TOTAL A B C D 300 2 890 487 619 646 508 DCE UNIT 6 POINT LOADS LBS TOTAL A B C D E F 300 2 890 415 471 528 551 492 433 DCG UNIT 4 POIN...

Page 13: ...036 21359 001 B 0302 Unitary Products Group 13 BASE RAIL 3 56 3 69...

Page 14: ...036 21359 001 B 0302 14 Unitary Products Group...

Page 15: ...measuring ports shall be pro vided on the outside of the cabinet to allow accu rate air measurements of evaporator fan performance without removing panels or creating air by pass of the coils 7 Conden...

Page 16: ...spark ignition redundant main gas valve Ventor wheel shall be constructed of stainless steel for corrosion resistance 2 The heat exchanger shall be of the tubular type constructed of T1 40 aluminized...

Page 17: ...e outdoor and return air damper assembly to take in the design CFM of outdoor air to meet the mini mum ventilation requirement of the conditioned space during normal operation During economizer operat...

Page 18: ...pulley and belt for higher CFM and or static pressure require ments 9 WOOD SKID Allows unit to be handled with 90 forks 10 ECONOMIZER MOTORIZED DAMPER RAIN HOOD DCE CG300 only Contains all hood panels...

Page 19: ...036 21359 001 B 0302 Unitary Products Group 19...

Page 20: ...036 21359 001 B 0302 20 Unitary Products Group...

Page 21: ...036 21359 001 B 0302 Unitary Products Group 21...

Page 22: ...036 21359 001 B 0302 22 Unitary Products Group...

Page 23: ...036 21359 001 B 0302 Unitary Products Group 23...

Page 24: ...ge without notice Printed in U S A CD 6 21359 036 21359 001 B 0302 Copyright by Unitary Products Group 2002 All rights reserved Supersedes 036 21359 001 A 0302 Unitary 5005 Norman Products York OK Gro...

Reviews: