Unitary Products Group
- = Not applicable.
ACCESSORIES*
Refer to Price Manual for specific model numbers.
Hard Start Kit
- Provides increased starting torque for areas
with low voltage.
Compressor Blanket -
Designed to further reduce the nor-
mal compressor operating sound. Refer to price pages for
specific match-ups.
Off Cycle Timer Delay
- Provides a 5-minute off cycle to pre-
vent rapid recycling of the compressor.
Room Thermostats
- A wide selection of compatible thermo-
sets are available to provide optimum performance and fea-
tures for any installation.
1 Heat Stage only, manual, mechanical thermostat. Add sub-
base for 1H/1C.
1H/1C, manual change-over electronic non-programmable
thermostat.
1H/1C, auto/manual changeover, electronic programmable,
deluxe 7-day, thermostat.
1H/1C, auto/manual changeover, electronic programmable.
* For the most current accessory information, refer to the
price book or consult factory.
SOUND RATINGS*
*Rated in accordance with ARI Standard 270.
COOLING CAPACITY - With Air Handler Coils
UNIT MODEL
AIR HANDLER
COIL
1
MODEL
COOLING
MODEL
ELECTRIC
2
HEAT KW
W
RATED
CFM
NET MBH
SEER
W/O TXV
SEER
+ TXV
3
EER
TOTAL SENS.
1 PH 10 SEER AC WITH N1AH / G2FD
AM012M1021
N1AHB0806
10
17
G2FD024(S,H)17
450
14.5
10.4
10.00
-
10.00
AM018M1021
N1AHB0806
10
17
G2FD024(S,H)17
650
18.6
13.4
10.00
-
9.50
AM024M1021
N1AHB0806
10
17
G2FD024(S,H)17
850
23.4
16.8
10.00
-
9.15
AM030M1021
N1AHB1206
10,15,18
17
G2FD030(S,H)17
1050
28.2
20.3
10.00
-
9.00
1 PH 10 SEER AC / F2RP
4
,
5
AM012M1021
F2RP018
2,5,8
18
-
500
14.5
10.6
10.00
-
9.70
AM018M1021
F2RP/F2FP018
2,5,8
18
-
650
17.4
12.6
10.00
-
9.35
AM018M1021
F2RP/F2FP024
5,8,10
18
-
650
18.6
13.4
10.00
-
9.50
AM024M1021
F2RP/F2FP024
5,8,10
18
-
850
23.4
16.8
10.00
-
9.15
AM030M1021
F2RP/F2FP030
5,8,10,15
18
-
1050
28.4
20.3
10.00
-
9.05
AM030M1021
F2RP/F2FP036
5,8,10,15,19
21
-
1050
29.0
20.7
10.00
-
9.15
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210/240.
Cooling MBH based on 95°F outdoor ambient, 8
0
°F entering air temperature, 50% RH, and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power input in
watt-hours during the same period.
1. G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2. Single phase units require single phase 2HK heaters.
3. TXV = Use 1TV700 Series Kit.
4. To meet R=4.2 insulation requirements, substitute F2FP for F2RP
.
All ratings remain the same.
5. F2RP air handlers have B.O.D (Blower on Delay) standard.
UNIT MODEL
SOUND
RATINGS
DBA
012
72
018
74
024
75
030
76