![background image](http://html1.mh-extra.com/html/york/33p502-05/33p502-05_installation-manual_3520909007.webp)
7
Vertical Dimensional Data cont.
LL
1.8 in.
[4.6 cm]
Alternative
Power
Location
Disconnect Located on this
Side for a Right Return
Disconnect
Location
Power
Supply
Vertical Shown in
Left Return Configuration
Vertical
Models
Overall Cabinet
Water Connections
Electrical Knockouts
1
2
3
4
5
6
7
8
A
B
C
D
E
F
G
H
Loop
Knock-
out
J
K
L
Width
Depth
Height**
In
Out
HWG
In
HWG Out
Cond-
ensate
Water
FPT
HWG Pro-
visions
1/2 in.
cond
1/2 in.
cond
1 in.
cond
009-012
in.
22.5
22.2
23.7
2.6
5.6
N/A
N/A
8.8
1/2
N/A
7.4
3.4
5.4
cm.
57.2
56.4
60.2
6.6
14.2
N/A
N/A
22.4
12.7 mm
N/A
18.8
8.6
13.7
015-018
in.
22.5
22.2
36.2
2.6
7.6
1.4
2.9
10.8
3/4
0.875
9.4
5.4
7.4
cm.
57.2
56.4
91.9
6.6
19.3
3.6
7.4
27.4
19.1 mm
22.2 mm
23.9
13.7
18.8
024-030
in.
22.5
26.2
40.2
2.6
7.6
1.4
4.4
10.8
3/4
0.875
10.1
6.1
8.1
cm.
57.2
66.5
102.1
6.6
19.3
3.6
11.2
27.4
19.1 mm
22.2 mm
25.7
15.5
20.6
036
in.
22.5
26.2
44.2
2.6
7.6
1.4
4.4
10.8
3/4
0.875
10.1
6.1
8.1
cm.
57.2
66.5
112.3
6.6
19.3
3.6
11.2
27.4
19.1 mm
22.2 mm
25.7
15.5
20.6
041
in.
22.5
26.2
44.2
2.6
7.6
1.4
2.9
10.8
3/4
0.875
10.1
6.1
8.1
cm.
57.2
66.5
112.3
6.6
19.3
3.6
7.4
27.4
19.1 mm
22.2 mm
25.7
15.5
20.6
042-048
in.
25.5
31.2
44.2
2.6
7.6
1.4
4.4
10.8
1
0.875
10.1
6.1
8.1
cm.
64.8
79.2
112.3
6.6
19.3
3.6
11.2
27.4
25.4 mm
22.2 mm
25.7
15.5
20.6
060
in.
25.5
31.2
48.2
2.6
7.6
1.4
4.4
10.8
1
0.875
10.1
6.1
8.1
cm.
64.8
79.2
122.4
6.6
19.3
3.6
11.2
27.4
25.4 mm
22.2 mm
25.7
15.5
20.6
070
in.
25.5
31.2
52.2
2.6
7.6
1.4
4.4
10.8
1
0.875
10.1
6.1
8.1
cm.
64.8
79.2
132.6
6.6
19.3
3.6
11.2
27.4
25.4 mm
22.2 mm
25.7
15.5
20.6
Vertical
Models
Discharge Connection
duct fl ange installed (±0.10 in)
Return Connection*
using deluxe fi lter rack (±0.10 in)
M
N
P
Q
R
S
T
U
V
W
Filter Rack
Width
Supply
Width
Supply
Depth
Return
Depth
Return
Height
009-012
in.
2.2
10.0
10.0
6.1
9.4
9.4
2.1
18.1
10.0
1.9
cm.
5.6
25.4
25.4
15.5
23.9
23.9
5.3
46.0
25.4
4.8
015-018
in.
2.2
14.0
14.0
4.1
4.3
7.7
2.1
18.1
20.0
1.9
cm.
5.6
35.6
35.6
10.4
10.9
19.6
5.3
46.0
50.8
4.8
024-030
in.
2.2
14.0
14.0
6.1
4.5
7.7
2.1
22.1
22.1
1.9
cm.
5.6
35.6
35.6
15.5
11.4
19.6
5.3
56.1
56.1
4.8
036
in.
2.2
14.0
14.0
6.1
4.5
7.7
2.1
22.1
26.1
1.9
cm.
5.6
35.6
35.6
15.5
11.4
19.6
5.3
56.1
66.3
4.8
041
in.
2.2
18.0
18.0
4.1
3.9
3.9
2.1
22.1
26.1
1.9
cm.
5.6
45.7
45.7
10.4
9.9
9.9
5.3
56.1
66.3
4.8
042-048
in.
2.2
18.0
18.0
6.6
4.6
6.3
1.6
28.1
26.0
2.0
cm.
5.6
45.7
45.7
16.8
11.7
16.0
4.1
71.4
66.0
5.1
060
in.
2.2
18.0
18.0
6.6
4.6
6.3
1.6
28.1
30.0
2.0
cm.
5.6
45.7
45.7
16.8
11.7
16.0
4.1
71.4
76.2
5.1
070
in.
2.2
18.0
18.0
6.6
4.6
6.3
1.6
28.1
34.0
2.0
cm.
5.6
45.7
45.7
16.8
11.7
16.0
4.1
71.4
86.4
5.1
11/10/09
Condensate is 3/4 in. PVC female glue socket and is switchable from side to front.
*Dimensions for return connections are for the deluxe fi lter rack that is suitable for ducted return applications and extends 3.25 in. [8.26 cm]
from the unit. The open fi lter rack, used in non-ducted returns, extends 2.2 in. [5.59 cm] from the unit.
**Discharge
fl
ange is
fi
eld installed and extends 1 in. (25.4 mm) from top of cabinet.
Vertical Models
LL
009-012
Externally Mounted
015-018
18.8 [47.8]
024-030
14.3 [36.3]
036
15.3 [38.9]
042-048
14.3 [36.3]
060
14.3 [36.3]
070
14.3 [36.3]
Dimensions in inches [cm]
02/06/13
Vertical Disconnect
When using disconnect, do not use dimension L from the
standard vertical dimensional data. Use dimension LL from the
vertical disconnect dimensional data.
LX ULTRA SERIES INSTALLATION MANUAL