-50-
The repair is authorized.
Yes
Repair
If there is no improvement with
above countermeasures and repair.
No
Immediately stop
using the tool.
〇
Ask your YOKOTA dealer
for repair.
Countermeasures
Switch R and L
securely
Pressure and adjust bolt adjustment
Low r.p.m.
Faulty motor part
Symptoms
Supposed causes
Faulty
impulse part
The tool rotates under no load
Daily check: Before use, check generated torque of a tool.
●
Symptoms of troubles and countermeasures
Reverse lever opening and closing operation failure
Too low air pressure
Damaged
Ball bearing
Silencer jam
Throttle knob opening and closing operation failure
Impulse unit
deterioration
Oil leak
Pulse number more than the default value
Pulse number less than the default value
Ball bearing failure
Vane worn-out
Adjustment failure for a rotor and upper plate
Motor case cover tightening failure
Incomplete cleaning of motor part
Dull sound
Faulty fly-out of vane
Dust contamination
Air leakage by damaged packing
Low torque (Insufficient tightening torque)
Check and countermeasures
Summary of Contents for YED-90
Page 3: ...1...
Page 4: ...2 1 100...
Page 5: ...3 5...
Page 6: ...4 85dB 85dB...
Page 7: ...5...
Page 8: ...6...
Page 9: ...7...
Page 10: ...8 1 2 3 TKa 46 32 ISO VG32...
Page 20: ...18 0 4 0 6MPa 5 40 35 80...
Page 21: ...19 10...
Page 22: ...20...
Page 23: ...21 1 2...
Page 24: ...22...
Page 25: ...23 6 6 10...
Page 26: ...24 OFF Ni Cd...
Page 27: ...25 30 15m 15m...
Page 49: ...47...
Page 50: ...48 R L Yes No...
Page 51: ...49 Yes No...