YOKOGAWA UTAdvanced UP55A Technical Information Download Page 18

Output Setting

Menu

Symbol

Name

Display level

Setting range

Initial value

User setting

OUT

OT

Output type selection

EASY

Control output or Heating-side control output (Lower two digits)
00: OFF
01: OUT terminals (voltage pulse)
02: OUT terminals (current)
03: OUT terminals (relay/triac)
04: OUT2 terminals (voltage pulse)
05: OUT2 terminals (current)
06: OUT2 terminals (relay/triac)
Cooling-side control output (Upper two digits)
00: OFF
01: OUT terminals (voltage pulse)
02: OUT terminals (current)
03: OUT terminals (relay/triac)
04: OUT2 terminals (voltage pulse)
05: OUT2 terminals (current)
06: OUT2 terminals (relay/triac)

Standard type: 00.03
Heating/cooling type: 06.03

CT

Control output cycle time
Heating-side control output cycle time (in
Heating/cooling control)

EASY

30.0 s

CTc

Cooling-side control output cycle time

EASY

30.0 s

V.AT

Automatic valve position adjustment

EASY

OFF: Stop automatic adjustment
ON: Start automatic adjustment

OFF

V.RS

Valve position setting reset

EASY

Setting V.RS to ON resets the valve adjustment settings and causes the
indication “V.RS” to blink.

OFF

V.L

Fully-closed valve position setting

EASY

Pressing the SET/ENTER key with valve position set to the fullyclosed position
by Down arrow key causes the adjusted value to be stored. When V.L
adjustment is complete, V.L stops blinking.

-

V.H

Fully-open valve position setting

EASY

Pressing the SET/ENTER key with valve position set to the fullyopened position
by Up arrow key causes the adjusted value to be stored. When V.H adjustment
is complete, V.H stops blinking.

-

TR.T

Valve traveling time

STD

5 to 300 s

60 s

V.MOD

Valve adjusting mode

STD

0: Valve position feedback type
1: Valve position feedback type
(moves to the estimating type if a feedback input error or break occurs.)
2: Valve position estimating type

0

RTS

Retransmission output type of RET

EASY

OFF: Disable
PV1: PV
SP1: SP
OUT1: OUT (Valve opening: 0 to 100 % in Position proportional control)
LPS: 15 V DC loop power supply
PV2: Loop-2 PV
SP2: Loop-2 SP
OUT2: Loop-2 OUT
TSP1: Target SP
HOUT1: Heating-side OUT
COUT1: Cooling-side OUT
MV1: Position proportional output internal computed value)
TSP2: Loop-2 target SP
HOUT2: Loop-2 heating-side OUT
COUT2: Loop-2 cooling-side OUT
MV2: Loop-2 position proportional output (internal computed value)
PV: PV terminals analog input
RSP: RSP terminals analog input
AIN2: AIN2 terminals analog input
AIN4: AIN4 terminals analog input

Loop-2 setting values are unavailable in Single-loop control.

PV1

RTH

Maximum value of retransmission output scale
of RET

STD

100 % of PV input range

RTL

Minimum value of retransmission output scale
of RET

STD

0 % of PV input range

O1RS

Retransmission output type of OUT current
output

STD

Same as RTS

OFF

O1RH

Maximum value of retransmission output scale
of OUT current output

STD

-

O1RL

Minimum value of retransmission output scale
of OUT current output

STD

-

O2RS

Retransmission output type of OUT2 current
output

STD

Same as RTS

OFF

O2RH

Maximum value of retransmission output scale
of OUT2 current output

STD

-

O2RL

Minimum value of retransmission output scale
of OUT2 current output

STD

-

OU.H

100% segmental point of OUT current output

PRO

100.0%

OU.L

0% segmental point of OUT current output

PRO

0.0%

OU2.H

100% segmental point of OUT2 current output PRO

100.0%

OU2.L

0% segmental point of OUT2 current output

PRO

0.0%

RET.H

100% segmental point of RET current output

PRO

100.0%

RET.L

0% segmental point of RET current output

PRO

0.0%

OU.A

OUT current output range

STD

4-20

OU2.A

OUT2 current output range

STD

4-20

RET.A

RET current output range

STD

4-20

Heater Break Alarm Setting

Menu

Symbol

Name

Display level

Setting range

Initial value

User setting

HBA

HB1.S

Heater break alarm-1 function selection

EASY

1

HB2.S

Heater break alarm-2 function selection

EASY

1

HB1

Heater break alarm-1 current setpoint

EASY

OFF

HB2

Heater break alarm-2 current setpoint

EASY

OFF

CT1.T

CT1 coil winding number ratio

EASY

800

CT2.T

CT2 coil winding number ratio

EASY

800

HDN1

Heater break alarm-1 Ondelay timer

STD

0.00

HDN2

Heater break alarm-2 Ondelay timer

STD

0.00

HDF1

Heater break alarm-1 Offdelay timer

PRO

0.00

HDF2

Heater break alarm-2 Offdelay timer

PRO

0.00

HB1.D

Heater break alarm-1 contact type

PRO

CLS

HB2.D

Heater break alarm-2 contact type

PRO

CLS

RS-485 Communication Setting

(E3 terminal

area)

(E4 terminal

area)

Menu

Symbol

Name

Display level

Setting range

Initial value

User setting

User setting

R485

PSL

Protocol selection

EASY

PCL: PC link communication
PCLSM: PC link communication (with checksum)
LADR: Ladder communication
CO-M: Coordinated master station
MBASC: Modbus (ASCII)
MBRTU: Modbus (RTU)
CO-S2: Coordinated slave station (Loop-2 mode)
P-P: Peer-to-peer communication

MBRTU

BPS

Baud rate

EASY

600: 600 bps
1200: 1200 bps
2400: 2400 bps
4800: 4800 bps
9600: 9600 bps
19200: 19.2k bps
38400: 38.4k bps (except for communication of E4 terminal area)

19200

PRI

Parity

EASY

NONE: None
EVEN: Even
ODD: Odd

EVEN

STP

Stop bit

EASY

1: 1 bit, 2: 2 bits

1

DLN

Data length

EASY

7: 7 bits, 8: 8 bits

8

ADR

Address

EASY

1 to 99

1

RP.T

Minimum response time

PRO

0 to 10 (x10ms)

0

0.5 to 1000.0 s

When RTS = PV1, SP1, PV2, SP2, TSP1, TSP2, PV, RSP, AIN2, or AIN4,
RTL + 1 digit to 30000
-19999 to RTH - 1 digit
Decimal point position:
When RTS=PV1, SP1, or TSP1, decimal point position is same as that of PV
input.
When RTS=PV2, SP2, or TSP2, decimal point position is same as that of RSP
input.
When RTS=PV, decimal point position is same as that of PV input scale.
When RTS=RSP, decimal point position is same as that of RSP input scale.
When RTS=AIN2, decimal point position is same as that of AIN2 scale.
When RTS=AIN4, decimal point position is same as that of AIN4 scale.

When O1RS = PV1, SP1, PV2, SP2, TSP1, TSP2, PV, RSP, AIN2, or AIN4,
O1RL + 1 digit to 30000
-19999 to O1RH - 1 digit
Decimal point position:
When O1RS=PV1, SP1, or TSP1, decimal point position is same as that of PV
input.
When O1RS =PV2, SP2, or TSP2, decimal point position is same as that of RSP
input.
When O1RS =PV, decimal point position is same as that of PV input scale.
When O1RS =RSP, decimal point position is same as that of RSP input scale.
When O1RS =AIN2, decimal point position is same as that of AIN2 scale.
When O1RS =AIN4, decimal point position is same as that of AIN4 scale.

When O2RS = PV1, SP1, PV2, SP2, TSP1, TSP2, PV, RSP, AIN2, or AIN4,
O2RL + 1 digit to 30000
-19999 to O2RH - 1 digit
Decimal point position:
When O2RS=PV1, SP1, or TSP1, decimal point position is same as that of PV
input.
When O2RS =PV2, SP2, or TSP2, decimal point position is same as that of RSP
input.
When O2RS =PV, decimal point position is same as that of PV input scale.
When O2RS =RSP, decimal point position is same as that of RSP input scale.
When O2RS =AIN2, decimal point position is same as that of AIN2 scale.
When O2RS =AIN4, decimal point position is same as that of AIN4 scale.

-100.0 to 200.0%

4-20: 4 to 20 mA
0-20: 0 to 20 mA
20-4: 20 to 4 mA
20-0: 20 to 0 mA

0: Heater current measurement
1: Heater break alarm

OFF, 0.1 to 300.0 Arms

1 to 3300

0.00 to 99.59 (minute.second)

CLS: When the event occurs, the contact is closed.
OPN: When the event occurs, the contact is opened.

Page 18 / 25

Summary of Contents for UTAdvanced UP55A

Page 1: ...UTAdvanced UP55A Program Controller Parameter Maps and Lists TI 05P02C41 01EN Copyright July 2011 1st Edition July 2011 Page 1 25...

Page 2: ...eet describes the setting range and initial value of operation parameters and setup parameters There is a column for user settings Program Data Sheet This sheet can be used for recording the setting v...

Page 3: ...inal area E1 to E4 in the Parameter Setting Display Displays a parameter symbol Displays the setting conditions of the parameter display level function Parameter display level EASY PRO Easy setting mo...

Page 4: ...t is blinking to move between digits according to the parameter Description Used to switch the Operation Displays Press the key in the Operation Display to switch the provided Operation Displays Press...

Page 5: ...parameter and operation status Parameter Display Transition and Setup Operation To move to the Operation Parameter Setting Display To move to the Setup Parameter Setting Display To move to the Operati...

Page 6: ...he Up or Down arrow key to change the setpoint 6 Press the SET ENTER key to register the setpoint the setpoint stops blinking This completes the setting procedure How to Cancel Parameter Setting To ca...

Page 7: ...How to Set Parameter Setpoint Numeric Value Setting Selection Data Setting Time minute second Setting Page 7 25...

Page 8: ...14 segments Alphabet Symbol display and Data display 11 segments Alphabet Group display 7 segments Alphabet PV display 14 segments Symbol The following shows the parameter symbols menu symbols alphanu...

Page 9: ...CYCL 1 T ON16 99 T ON16 VT7 R STRT 1 T OF16 99 T OF16 VT8 R END END END HY1 END HY2 HY3 HY4 HY5 HY6 HY7 Symbol Corresponding parameters are displayedin all modes HY8 1 PYS1 2 PYS2 3 PYS3 4 PYS4 END MO...

Page 10: ...unction Numbering DI1 DI3 Contact Type Setting DI Setting E1 terminal area DI Setting E2 terminal area DI Setting E3 terminal area DI Setting E4 terminal area AL1 AL3 Function Registration DO Setting...

Page 11: ...Data Sheet WT SW1 Wait function ON OFF 1 STD OFF Disable ON Enable OFF See Sheet Program Data Sheet WZ UP1 Upper side wait zone 1 STD 0 5 of PV input range See Sheet Program Data Sheet WZ LO1 Lower s...

Page 12: ...ern 2 retransmission PT2 G ON Menu Symbol Name Display level Setting range Initial value User setting User setting LOC LSP Local target setpoint EASY 0 0 to 100 0 of PV input range EU Setting range P...

Page 13: ...hysteresis EASY 10 HY4 Alarm 4 hysteresis EASY 10 HY5 Alarm 5 hysteresis EASY 10 HY6 Alarm 6 hysteresis EASY 10 HY7 Alarm 7 hysteresis EASY 10 HY8 Alarm 8 hysteresis EASY 10 DYN1 Alarm 1 On delay time...

Page 14: ...haracteristic changes compared with response mode 3 Hunting suppressing function response mode Enables quick follow up and short converging time of PV for the changed SP 4 Overshoot suppressing functi...

Page 15: ...segment linearizer 3 output 2 PRO 0 0 A3 10 segment linearizer 3 input 3 PRO 0 0 B3 10 segment linearizer 3 output 3 PRO 0 0 A4 10 segment linearizer 3 input 4 PRO 0 0 B4 10 segment linearizer 3 outp...

Page 16: ...of PV input scale EASY Depends on the input type SL Minimum value of PV input scale EASY Depends on the input type BSL PV input burnout action STD OFF Disable UP Upscale DOWN Downscale Depends on the...

Page 17: ...SH Maximum value of AIN4 aux analog input scale EASY Depends on the input type SL Minimum value of AIN4 aux analog input scale EASY Depends on the input type BSL AIN4 aux analog input burnout action S...

Page 18: ...UT current output range STD 4 20 OU2 A OUT2 current output range STD 4 20 RET A RET current output range STD 4 20 Heater Break Alarm Setting Menu Symbol Name Display level Setting range Initial value...

Page 19: ...10M 10 minutes 30M 30 minutes 60M 60 minutes OFF When each parameter is displayed the terminal area E3 is displayed on Group display DeviceNet Communication Setting Menu Symbol Name Display level Set...

Page 20: ...when there has been no keystroke operation for 5 minutes OFF ON ON MLSD Least significant digital mask of PV display STD OFF With least significant digit ON Without least significant digit OFF Set a d...

Page 21: ...FF INIT INIT menu lock PRO OFF VER VER menu lock PRO OFF LVL LVL menu lock PRO OFF MODE MODE menu lock PRO OFF CS CS menu lock PRO OFF PROG PROG menu lock PRO OFF LOC LOC menu lock PRO OFF EDIT EDIT m...

Page 22: ...et output STD 0 Preset output 1 0 output 2 100 output Set preset output value when the input burnout or ADC error occurs Manual output is prioritized when the input burnout occurs in MAN 0 C GRN Respo...

Page 23: ...3 ECU 3 version EASY ECU4 ECU 4 version EASY PARA Parameter version EASY H VER Product version EASY SER1 Serial number 1 EASY SER2 Serial number 2 EASY MAC1 MAC address 1 EASY MAC2 MAC address 2 EASY...

Page 24: ...T ON7 On time of time event 7 T OF7 Off time of time event 7 TME8 Start condition of time event 8 T ON8 On time of time event 8 T OF8 Off time of time event 8 TME9 Start condition of time event 9 T O...

Page 25: ...on of time event 10 T ON10 On time of time event 10 T OF10 Off time of time event 10 TME11 Start condition of time event 11 T ON11 On time of time event 11 T OF11 Off time of time event 11 TME12 Start...

Reviews: