Allowable power interruption time: 20 ms (at 100 V AC)
• Withstanding voltage
2300 V AC for 1 minute between primary and
secondary terminals (UL, CSA)
3000 V AC for 1 minute between primary and
secondary terminals (CE)
1500 V AC for 1 minute between primary terminals
500 V AC for 1 minute between secondary terminals
(Primary terminals = Power (*) and relay output
terminals, Secondary terminals = Analog I/O signal
terminals, contact input terminals, communication
terminals, and functional grounding terminals.)
*:
Power terminals for 24 V AC/DC models are the
secondary terminals.
• Insulation resistance
Between power supply terminals and a grounding
terminal: 20 MΩ or more at 500 V DC
• Isolation specifications
The circuits divided by lines are insulated mutually.
Retransmission (analog) output terminals
PV (universal) input terminals
Control relay (c-contact) output terminals
Alarm-1 relay (a-contact) output terminals
Alarm-2 relay (a-contact) output terminals
Alarm-3 relay (a-contact) output terminals
Internal
circuits
Power
supply
Contact input terminals
RS485 communication terminals
Ethernet communication terminal
Environmental Conditions
Normal operating conditions
• Ambient temperature: -10 to 50°C (-10 to 40°C for
side-by-side mounting of controllers)
• Ambient humidity: 20 to 90% RH (no condensation)
• Magnetic field: 400 A/m or less
• Continuous vibration (at 5 to 9 Hz) Half amplitude of
1.5 mm or less
(at 9 to 150 Hz) 4.9 m/s
2
or less, 1 oct/min for 90 min-
utes each in the three axis directions
• Rapid vibration: 14.7 m/s
2
, 15 s or less
• Impact: 98 m/s
2
or less, 11 msec.
• Installation altitude: 2,000 m or less above sea level
• Warm-up time: 30 minutes or more after the power is
turned on
• Start-up time within 10 s
Transportation and Storage Conditions
• Temperature: -25 to 70°C
• Temperature change rate: 20°C per hour or less
• Humidity: 5 to 95%RH (no condensation)
Effects of Operating Conditions
• Effect of ambient temperature
For voltage or TC input:
±1 μ V/°C or ±0.01% of F.S. (instrument
range)/°C, whichever is greater
For RTD input:
±0.05°C/°C (ambient temperature) or less
For current input:
±0.01% of F.S. (instrument range)/°C
For analog output:
±0.02% of F.S./°C or less
• Effect of power supply fluctuation:
For analog input: ±0.05% of F.S. (instrument range)
or less
For analog output: ±0.05% of F.S. or less
(Each within rated voltage range)
Retransmission Output Specifications
• Number of points: 1 point
• Output function: current output
4 to 20 mA DC or 0 to 20 mA DC/load
resistance 600 Ω or less
• Current output accuracy (conversion accuracy from
PV display on the set scale): ±0.1% of span (how-
ever, ±5% of span for 1 mA or less)
The accuracy is that in the basic operating
conditions: 23 ±2°C, 55 ±10%RH, and power
frequency at 50/60 Hz
This is not conversion accuracy through input
and output but the performance of transmission
output itself.
Contact Input Specifications
• Number of points: 2 points
• Input type: no-voltage contact input or transistor con-
tact input
• Input contact capacity: 12 V DC, 10 mA or more
Be sure to use a contact with a minimum ON
current of 1 mA or less
• ON/OFF detection
No-voltage contact input:
Contact resistance 1 kΩ or less in ON state
Contact resistance 50 kΩ or more in OFF state
Transistor contact input:
2 V or less in ON state
Leak current 100 μ A or less in OFF state
• Status detection minimum hold time: 250 ms
• Application: Confirmation operation, etc.
Safety and EMC Standards
• Safety:
Compliant with IEC/EN 61010-1 (CE), IEC/EN 61010-
2-201 (CE), IEC/EN 61010-2-030 (CE), approved by
CAN/CSA C22.2 No. 61010-1 (CSA), approved by UL
61010-1. Certified for FM-3810 and FM-3545.
Installation category: II
Pollution degree: 2
Measurement category: I (CAT I) (UL, CSA)
O (Other) (CE)
Rated measurement input voltage: Max. 10 V DC
Rated transient overvoltage: 1500 V (
*
)
*:
This is a reference safety standard value for measure-
ment category I of CSA/UL 61010-1, and for measure-
ment category O of IEC/EN 61010-2-030. This value is
not necessarily a guarantee of instrument performance.
• EMC standards:
Compliant with
CE marking
EN 61326-1 Class A, Table 2 (For use in industrial
locations),
EN 61326-2-3
*: The instrument continues to operate at a measurement
accuracy of within ±20% of the range during testing.
EN 55011 Class A, Group 1
EN 61000-3-2 Class A
EN 61000-3-3
EMC Regulatory Arrangement in Australia and New Zealand
EN 55011 Class A, Group 1
Power Supply Specifications and Isolation
• Power supply
Rated voltage: 100 to 240 V AC (+10%/-15%), 50/60 Hz
24 V AC/DC (+10%/-15%) (When the
/DC option is specified)
• Power consumption: 18 VA (For the /DC option.
DC: 9 VA, AC: 14 VA)
• Storage: Nonvolatile memory