![YOKOGAWA ROTAMASS Total Insight User Manual Download Page 24](http://html.mh-extra.com/html/yokogawa/rotamass-total-insight/rotamass-total-insight_user-manual_911337024.webp)
Quick Reference Instruction Manual for Spare
Sensor replacement
Wiring
24 / 76
IM01U10A01-00EN-R, 1
st
edition, 2019-12-09
6.4.3.1 Connection terminals
The delivery includes an operating tool for connecting the connecting cable to the
connection terminals.
D
+
D
-
S1
+
S1
-
S2
+
S2
-
T
P1
T
P2
T
P3
D
+
D
-
S1
+
S1
-
S2
+
S2
-
TP1
TP2
TP3
COM
3
2
1
1
2
3
4
5
6
Fig. 13:
Connection terminal circuits (transmitter on the left side, sensor on the right side)
1
Driver circuit (D+/D-)
4
Signal grounding
2
Sensor circuits (S1+/S1-, S2+/S2-)
5
Transmitter
3
Temperature measurement circuit
(TP1, TP2, TP3)
6
Sensor
Installation of
standard connecting
cable option L
␣␣␣
Fig. 14:
Transmitter and sensor interconnection diagram
1
Sensor
2
Transmitter
3
Potential equalization system