6-12
IM MV1000-01E
6.6 Usng Dsplay Zones
This section explains how to assign each channel to a waveform display zone so that
waveforms do not overlap.
For an explanation of this function, see section 1.4.
Dsplay
MV1000
Press
MENU
and then select
Menu tab
>
Meas channel
>
Zone, Scale
.
MV2000
Press
MENU
and then select
Menu tab
>
Meas channel
>
Zone, Scale, Bar graph
.
Settngs
• Frst-CH, Last-CH
Select the target channels. The settings selected here will be applied to these
channels.
• Zone > Lower, Zone > Upper
Set the zone where waveforms will be displayed. Set Lower and Upper as
percentages of the maximum display width. Set Upper to a value greater than Lower,
and set the zone width (Upper – Lower) to greater than or equal to 5%.
Lower: 0 to 95%