4.8 Sweep Setting and Manipulation
99
IM FG410-01EN
4.8.6 Setting amplitude sweep
For the manipulation methods that are common with the sweep setting screen, refer to
pp. 83 and 86.
a) Amplitude sweep example
The following is an example of continuous, linear shuttle sweep.
Shuttle sweep
b) Selecting amplitude sweep
When [Mode] (oscillation mode) is set to
[Sweep] (sweep), set [Type] (sweep type)
on the 2nd page of the setting screen to
[Amptd] (amplitude).
c) Waveforms for which amplitude sweep is not possible
Amplitude sweep is not possible for DC.
d) Setting items required for amplitude sweep
Set the following items on the 2nd page of the setting screen. The amplitude settings on the
1st page of the setting screen are disabled.
• Start amplitude [Start]
• Stop amplitude [Stop]
• Sweep time [Time]
This is the transition time from the start amplitude to the stop amplitude.
• Sweep mode [SwpMode]
Continuous, single-shot, and gated single-shot can be chosen from.
• Sweep function [SwpFctn]
One-way/shuttle can be chosen from.
Setting with [Center] (center amplitude) and [Span] (span amplitude) instead of the start
amplitude and stop amplitude is also possible.
When the sweep mode is single-shot or gated single-shot, [Trig] (trigger condition) must be
set.
Sweep time
Sweep time
Sweep value
Output signal
Start value
Stop value
Select [Amptd] in
[Type] and then
press the ENTER
key