![YOKOGAWA F3YP14-0N User Manual Download Page 33](http://html1.mh-extra.com/html/yokogawa/f3yp14-0n/f3yp14-0n_user-manual_910940033.webp)
3-10
IM 34M6H55-02E
1st Edition : Apr 1, 2002-00
3.7 Deviation Pulse Clear Signal Output
In an origin search using a servo driver, this outputs a deviation pulse clear signal at the
end of the origin search to the servo driver. The deviation pulse clear signal is
connected to the input of the servo driver.
The length of the deviation pulse clear signal output is defined in a parameter.
When the Z-phase pulse count is set to 0, no deviation pulse clear signal is generated.
Figure 3.10 Deviation Pulse Clear Signal Output
Search speed 2
Z-phase pulse
Deviation pulse clear
Deviation pulse clear time
Origin input
F030701.VSD