IM 12D08N05-01E
3-2
<3. INSTALLATION AND WIRING>
Unit: mm (inch)
220(8.66")
184(7.2")
72(2.8")
A
D
E
F
B
C
A : For output signal
B : For contact input
C : For sensor cable
D : For contact output (S1 and S2)
E : For contact output (S3 and S4)
F : For power supply
Adapter
49
(1.93")
G1/2 screw (/AFTG),
1/2 NPT screw (/ANSI)
M20 screw (/AM20)
Approx.
55(2.2")
144(5.67")
144(5.67")
20
(0.79")
20
(0.79")
121.5(4.78")
24.5(1")
Adapter for Conduit Work (optional)
(option code : / AFTG, / ANSI, / AM20)
4x M6 screw
depth 7
M20 cable gland
(When shipped, not installed)
Grounding terminal (M4 screw)
Hood (Option code: /H5, some cutout on the left side cover)
Figure 3.1 Housing dimensions and layout of glands