10-9
IM 01F06A00-01E
10. EXPLOSION PROTECTED TYPE INSTRUMENT
10.4 CSA
10.4.1 Technical Data
• Explosion Proof
Applicable Standard: C22.1-98, C22.2 No.0-M1991, C22.2
No.4-04, C22.2 No.0.5-1982, C22.2
No. 25-1966, C22.2 No. 30-M1986,
C22.2 No. 94-M1991, C22.2 No. 142-
M1987, C22.2 No. 61010-1-04, ANSI/
ISA-12.27.01-2003
Certificate
: 1166201
Type of Protection: Explosionproof for Class I, B, C and D;
Class II, Groups E, F and G; Class III.
For Class I, Division 2 location:
“FACTORY SEALED, CONDUIT SEAL NOT
REQUIRED.”
Enclosure : Type 4X
(Integral Type Flowmeter and Remote Type Flowmeter)
Temperature Code Ambient Temperature Process Temperature
T6
T5
T4
T3
T2
T1
60
°
C
60
°
C
60
°
C
60
°
C
60
°
C
60
°
C
85
°
C
100
°
C
135
°
C
200
°
C
300
°
C
450
°
C
T100401_1.EPS
Temperature Code: T6 (Remote Type Converter)
Ambient Temperature: -29 to +60
°
C (Integral Type Flowmeter
and Remote Type Flowmeter)
-40 to +60
°
C (Remote Type Converter)
Power Supply: 42Vdc max. (Integral Type Flowmeter and
Remote Type Converter)
Output Supply (Integral Type Flowmeter):
Current Output; 4 to 20mAdc
Pulse Output; on=2Vdc, 200mA
Off=42Vdc, 4mA
Output Signal (Remote Type Flowmeter):
Output Signal; 30Vp-p, 100
µ
Ap-p
Input/Output signal (Remote Type Converter):
CUrrent Output; 4 to 20mAdc
Pulse; On=2Vdc, 20mA
Off=42Vdc, 4mA
Input Signal; 30Vp-p, 100
µ
Ap-p
Maximum Working Pressure: 16MPa (DY015 to DY200)
5MPa (DY200 and DY300)
Electrical Connection: ANSI 1/2 female(Special)
• Intrinsically Safe
Applicable Standard: C22.2 No. 0.4-2004, C22.2 No. 157-
M1987, C22.2 No. 213-M1987, C22.2
No. 1010.1-92, CAN/CSA-E60079-
0:02, CAN/CSA-E60079-11:02, CAN/
CSA-E60079-15:02, ANSI/ ISA-
12.27.01-2003
Certificate
: 1198227
Type of Protection: Ex ia IIC T4...T1 and Ex nC IIC T4...T1
(Integral Type Flowmeter and Remote
Type Flowmeter)
Ex ia IIC T4 and Ex nC IIC T4
(Remote Type Converter)
(Integral Type Flowmeter and Remote Type Flowmeter)
Temperature Code Ambient Temperature Process Temperature
T4
T3
T2
T1
60
°
C
60
°
C
60
°
C
60
°
C
135
°
C
200
°
C
300
°
C
450
°
C
T100401_2.EPS
Ambient Temperature: -29 to +60
°
C (Integral Type Flowmeter
and Remote Type Flowmeter)
-40 to +60
°
C (Remote Type Converter)
Degree of Protection of Enclosure: IP67
Electrical Parameters: Ui=30Vdc, Ii=165mAdc, Pi=0.9W
Ci=12nF, Li=0.15mH
Electrical Connection: ANSI 1/2 NPT female
Type of Protection: Intrinsically Safe for Class I,II,III, Div.1,
Groups A,B,C,D,E,F and G,
Non- incendive for Class I,II, DIV.2,
Groups A,B,C,D,E,F and G, Class III,
Div.1
(Integral Type Flowmeter and Remote Type Flowmeter)
Temperature Code Ambient Temperature Process Temperature
T4
T3
T2
T1
60
°
C
60
°
C
60
°
C
60
°
C
135
°
C
200
°
C
300
°
C
450
°
C
T100402.EPS
Temperature Code: T4 (Remote Type Converter)
Ambient Temperature: -40 to 60
°
C
Enclosure: Type 4X
Electrical Parameters: Vmax=30Vdc, Imax=165mAdc,
Pmax=0.9W, Ci=12nF, Li=0.15mH