IM 01C22K01-01E
8-5
8. BRAIN TERMINAL BT200 OPERATION
T0806.EPS
Auxiliary setting data 1
D
Menu name
AUX SET 1
—
NORMAL/REVERSE
NORMAL/REVERSE*
4
Output reversal
D40 REV OUTPUT
Impulse piping
accessing direction
D45 H/L SWAP
—
HIGH/LOW, –5 to 110%*
3
CPU error
D52 BURN OUT
Selected from mmH
2
O, mmAq,
mmWG, mmHg, Torr, Pa, hPa, kPa,
MPa, mbar, bar, gf/cm
2
, kgf/cm
2
,
inH
2
O, inHg, ftH
2
O, psi, or atm
Static pressure setting
units
D31 STAT. P. UNIT
Hardware error
D53
Same as A60
HOLD/HIGH/LOW, –5 to 110%*
3
ERROR OUT
Self-diagnostic
messages
—
D60 SELF CHECK
Auxiliary setting data 2
E
OFF/ON
Menu name
AUX SET 2
Bidirectional mode
E30 BI DIRE
MODE
Same as A60
Self-diagnostic
messages
E60 SELF CHECK
—
—
No.
Description
Remarks
Item
Menu name
Automatic setup
H
AUTO SET
—
Adjustment data
J
–5 to 110.0%*
3
Menu name
ADJUST
Automatic zero
adjustment
J10 ZERO ADJ
—
—
—
—
—
—
—
—
—
Manual zero
adjustment
J11 ZERO DEV.
ENABLE/INHIBIT
External zero-
adjustment screw
permission
J20 EXT. ZERO
ADJ
Same as A60
Self-diagnostic
messages
J60 SELF CHECK
Display the error
History of the errors
RECORD
Last error
P10
P11
ERROR REC 1
Display the error
One time before
ERROR REC 2
P12
Display the error
Two time before
ERROR REC 3
Menu name
Tests
K
TEST
–5 to 110%*
3
Displays ‘ACTIVE’
while executing
Test output % setting
K10 OUTPUT in %
Same as A60
Self-diagnostic
messages
K60 SELF CHECK
Menu name
Memo
M
P
MEMO
8 uppercase alphanumerics
Memo
M10 MEMO 1
8 uppercase alphanumerics
Memo
M20 MEMO 2
8 uppercase alphanumerics
P13
Display the error
Three time before
ERROR REC 4
P60
Same as A60
Self-diagnostic
messages
SELF CHECK
Memo
M30 MEMO 3
8 uppercase alphanumerics
Memo
M40 MEMO 4
8 uppercase alphanumerics
Memo
M50 MEMO 5
Same as A60
Self-diagnostic
messages
M60 SELF CHECK
–32000 to 32000
Automatic measure-
ment range lower
range value setup
H10 AUTO LRV
–32000 to 32000
Automatic
measurement range
higher range value
setup
H11 AUTO HRV
—
—
—
—
—
—
—
—
Same as A60
Self-diagnostic
messages
H60 SELF CHECK
Applica-
bility
P L
F
As specified when ordered.
If not specified, MPa.
If not specified, NORMAL.
NORMAL
HIGH
HIGH
OFF
Displays the same data as
C21.
Displays the same data as
C22.
Rewrita-
bility
Default Value
*1: In case of Model EJA120, static pressure cannot be measured. The display is always 0 MPa, but this is not a measured value.
*2: When Optional code /F1 is specified, substitute the value with 0.1.
*3: When Optional code /F1 is specified, substitute the value -5 with -2.5.
*4: Not applicable for Model EJA115.
*5: Applicable only for Model EJA118W, EJA118N, EJA118Y, EJA438W and EJA438N.
*6: See MWP(max. working pressure) on the nameplate. B40 shows an approximate value of maximum pressure for the capsule.
E10
E14
E15
DFS MODE
TEMP
SELECT
TEMP ZERO
DFS mode
Reference
temperature sensor
Zero shift
Conpensation setup
OFF/ON*
5
AMP.TEMP/CAP.TEMP*
5
±
10.00*
5
ON
CAP.TEMP
0.00