background image

5-55

IM 701310-17E

Commands

1

2

3

4

5

6

App

Index

:ANALysis:WPARameter<x>:HISTogram: 

MEASure:CURSor:DC:STATe

Function  Turns ON/OFF the measurement between cursors 

on the histogram of the waveform parameter 
measurement or queries the current setting.

Syntax

 

:ANALysis:WPARameter<x>:HISTogram: 
MEASure:PARameter:DC:STATe {<Boolean>}

 

:ANALysis:WPARameter<x>:HISTogram: 
MEASure:PARameter:DC:STATe?

 

<x> = 1 or 2

Example

  :ANALYSIS:WPARAMETER1:HISTOGRAM: 

MEASURE:CURSOR:DC:STATE ON

 

:ANALYSIS:WPARAMETER1:HISTOGRAM: 
MEASURE:CURSOR:DC:STATE? -> :ANALYSIS:
WPARAMETER1:HISTOGRAM:MEASURE:CURSOR:
DC:STATE 1

:ANALysis:WPARameter<x>:HISTogram: 

MEASure:CURSor:DC:VALue?

Function  Queries the measured value between cursors on the 

histogram of the waveform parameter measurement.

Syntax

 

:ANALysis:WPARameter<x>:HISTogram: 
MEASure:CURSor:DC:VALue?

 

<x> = 1 or 2

Example

  :ANALYSIS:WPARAMETER1:HISTOGRAM: 

MEASURE:CURSOR:DC:VALUE? -> :ANALYSIS:
WPARAMETER1:HISTOGRAM:MEASURE:CURSOR:
DC:VALUE 1.000E+00

:ANALysis:WPARameter<x>:HISTogram: 

MEASure:CURSor:LINKage

Function  Turns ON/OFF the histogram cursor link of the 

waveform parameter measurement or queries the 
current setting.

Syntax

 

:ANALysis:WPARameter<x>:HISTogram: 
MEASure:CURSor:LINKage {<Boolean>}

 

:ANALysis:WPARameter<x>:HISTogram: 
MEASure:CURSor:LINKage?

 

<x> = 1 or 2

Example

  :ANALYSIS:WPARAMETER1:HISTOGRAM: 

MEASURE:CURSOR:LINKAGE ON

  

 

:ANALYSIS:WPARAMETER1:HISTOGRAM: 
MEASURE:CURSOR:LINKAGE? -> :ANALYSIS:
WPARAMETER1:HISTOGRAM:MEASURE:CURSOR:
LINKAGE 1

:ANALysis:WPARameter<x>:HISTogram: 

MEASure:MODE

Function  Sets the automated measurement mode of the 

histogram display of the waveform parameter 
measurement or queries the current setting.

Syntax

 

:ANALysis:WPARameter<x>:HISTogram: 
MEASure:MODE {CURSor|OFF|PARameter}

 

:ANALysis:WPARameter<x>:HISTogram: 
MEASure:MODE?

 

<x> = 1 or 2

Example

  :ANALYSIS:WPARAMETER1:HISTOGRAM: 

MEASURE:MODE CURSOR

 

:ANALYSIS:WPARAMETER1:HISTOGRAM: 
MEASURE:MODE? -> :ANALYSIS:WPARAMETER1:
HISTOGRAM:MEASURE:MODE CURSOR

:ANALysis:WPARameter<x>:HISTogram: 

MEASure:PARameter?

Function  Queries all settings related to the automated 

measurement of histogram parameters of the 
waveform parameter measurement.

Syntax

 

:ANALysis:WPARameter<x>:HISTogram: 
MEASure:PARameter?

 

<x> = 1 or 2

Example

  :ANALYSIS:WPARAMETER1:HISTOGRAM: 

MEASURE:PARAMETER? -> :ANALYSIS:
WPARAMETER1:HISTOGRAM: 
MEASURE:PARAMETER:MEAN:STATE 1;: 
ANALYSIS:WPARAMETER1:HISTOGRAM:MEASURE: 
PARAMETER:PEAK:STATE 1;:ANALYSIS: 
WPARAMETER1:HISTOGRAM:MEASURE: 
PARAMETER:SD3INTEG:STATE 1;:ANALYSIS: 
WPARAMETER1:HISTOGRAM:MEASURE: 
PARAMETER:SDEVIATION:STATE 1;:ANALYSIS: 
WPARAMETER1:HISTOGRAM:MEASURE: 
PARAMETER:SDINTEG:STATE 1

:ANALysis:WPARameter<x>:HISTogram: 

MEASure:PARameter:ALL

Function  Turn ON/OFF all histogram parameters of the 

waveform parameter measurement.

Syntax

 

:ANALysis:WPARameter<x>HISTogram: 
MEASure:PARameter:ALL {<Boolean>}

 

<x> = 1 or 2

Example

  :ANALYSIS:WPARAMETER1:HISTOGRAM: 

MEASURE:PARAMETER:ALL ON

5.3  ANALysis Group

Summary of Contents for DL9040 Series

Page 1: ...IM 701310 17E 10th Edition Digital Oscilloscope DL9040 DL9140 DL9240 Series Communication Interface...

Page 2: ...CAN bus signal LIN bus signal SPI bus signal analysis function DL9000 Series Digital Oscilloscope SB5000 Series Vehicle Serial Bus Analyzer Power Supply Analysis Function User s Manual IM 701310 61E...

Page 3: ...eb page and then browse to the download page http tmi yokogawa com service support downloads Trademarks Microsoft MS DOS Visual C Windows and Windows NT are registered trademarks of Microsoft Corporat...

Page 4: ...ctions and specifications of the Ethernet interface Chapter 3 Overview of the GP IB Interface Describes the functions and specifications of the GP IB interface Chapter 4 Before Programming Describes t...

Page 5: ...dure Carry out the procedure according to the step numbers All procedures are written with inexperienced users in mind experienced users may not need to carry out all the steps Explanation This sectio...

Page 6: ...ese symbols are referred to as BNF Backus Naur Form symbols For details on the data see pages 4 5 and 4 6 Symbol Meaning Example Example of Input Defined value CHANnel x x 1 to 4 CHANNEL2 Select from...

Page 7: ...d 3 2 3 3 GP IB Interface Functions 3 3 3 4 GP IB Interface Specifications 3 4 3 5 Setting the DL9000 GP IB 3 5 3 6 Responses to Interface Messages 3 6 Chapter 4 Before Programming 4 1 Messages 4 1 4...

Page 8: ...29 TRIGger Group 5 149 5 30 WAVeform Group 5 200 5 31 ZOOM Group 5 202 5 32 Common Command Group 5 204 Chapter 6 Status Reports 6 1 Overview of the Status Report 6 1 6 2 Status Byte 6 3 6 3 Standard E...

Page 9: ...F PUSH FINE PUSH FINE SCALE SNAP CLEAR SNAP POWER COMP CH 1 CH 2 CH 3 CH 4 1 M 20 pF 150 Vrms CAT I 50 5 Vrms 10 Vpk LEVEL COUPLING DL9240L 10GS s 1 5GHz DIGITAL OSCILLOSCOPE SYSTEM key Press this key...

Page 10: ...125000 Approx 193 ms Approx 22 766 s 1250000 Approx 1606 ms Approx 224 890 s 2500000 Approx 3188 ms Approx 451 297 s 6250000 Approx 7841 ms Approx 1127 625 s Switching between Remote and Local Modes W...

Page 11: ...aken When Making Connections Connect the USB cable by inserting the connector firmly into the USB connector When connecting multiple devices using USB hubs connect the DL9000 to the USB hub that is cl...

Page 12: ...000 to activate the TMC Mass Storage or TMC Mass Storage setting Wait at least 10 seconds after you turn the power switch OFF and then turn the switch back ON Install YOKOGAWA s TMC Text and Measureme...

Page 13: ...USH FINE SCALE SNAP CLEAR SNAP POWER COMP CH 1 CH 2 CH 3 CH 4 1 M 20 pF 150 Vrms CAT I 50 5 Vrms 10 Vpk LEVEL COUPLING DL9240L 10GS s 1 5GHz DIGITAL OSCILLOSCOPE CLEAR key Press this key to switch fro...

Page 14: ...ns 1 Port number Ethernet 10001 tcp VXI 11 10240 tcp 10250 tcp 111 tcp and 111 udp Data Transfer Rates The response time when outputting waveform data is shown below as a reference Model 701313 main u...

Page 15: ...The REMOTE indicator at the top center of the screen disappears Key operations are enabled Settings entered in remote mode are retained even when the DL9000 switches to local mode Note The Ethernet V...

Page 16: ...DOW 1 WINDOW 2 MEASURE CURSOR TELECOM TEST PARAM VERTICAL CH 1 M 1 CH 2 CH 3 CH 4 M 2 M 3 M 4 POSITION TRIG D TRIG MODE HOLD OFF PUSH FINE PUSH FINE SCALE SNAP CLEAR SNAP POWER COMP CH 1 CH 2 CH 3 CH...

Page 17: ...I 11 When you select Network When you select VXI 11 Note Only the interface that you select after pressing Remote Control is valid The DL9000 does not accept commands that are transmitted to other uns...

Page 18: ...er you must configure the settings described below User Name and Password The Ethernet interface has a user authentication feature Set the DL9000 user name and password in advance If you select VXI 11...

Page 19: ...OLD OFF PUSH FINE PUSH FINE SCALE SNAP CLEAR SNAP POWER COMP CH 1 CH 2 CH 3 CH 4 1 M 20 pF 150 Vrms CAT I 50 5 Vrms 10 Vpk LEVEL COUPLING DL9240L 10GS s 1 5GHz DIGITAL OSCILLOSCOPE SYSTEM key Press th...

Page 20: ...L9000 ON Multiple cables can be used to connect multiple devices However no more than 15 devices including the controller can be connected on a single bus When connecting multiple devices each device...

Page 21: ...When Switching from Local to Remote Mode Receiving a REN Remote Enable message from the PC when the DL9000 is in the local mode causes the DL9000 to switch to the remote mode REMOTE is displayed in t...

Page 22: ...talker capability serial polling untalk on MLA My Listen Address and no talk only capability Listener L4 Basic listener capability unlisten on MTA My Talk Address and no listen only capability Service...

Page 23: ...ation Enter the following settings when using a controller to set information that can be specified through key operation on the DL9000 or when outputting setting parameters or output waveform data to...

Page 24: ...TCT Take Control are not supported Responses to a Multi Line Message Universal Command LLO Local Lockout Disables CLEAR on the front panel to prohibit switching to the local mode DCL Device Clear Same...

Page 25: ...ker designations The following five types are available LLO Local Lockout DCL Device Clear PPU Parallel Poll Unconfigure SPE Serial Poll Enable SPD Serial Poll Disable In addition listener address tal...

Page 26: ...he controller and the instrument Messages that are sent from the controller to the instrument are called program messages and messages that are sent back from the instrument to the controller are call...

Page 27: ...query is sent a response message must be received before the next program message can be sent If the next program message is sent before the response message is received in its entirety an error occu...

Page 28: ...e specified for each command even when commands belonging to the same command group are being concatenated Example ACQuire MODE NORMal PMT ACQuire INTERLeave 1 PMT Commands There are three types of co...

Page 29: ...ly in use It is important to remember that not all the group s information is necessarily returned as part of a response Header Interpretation Rules The instrument interprets the header that is receiv...

Page 30: ...ed as a program message unless changes are made to it query only command only the data section is returned However there are query only commands that return responses with the header attached Example...

Page 31: ...hysical value Frequency Example Time axis range Current TIMebase TDIV 1US Register Register value expressed as binary octal decimal or hexadecimal Example Extended event register value STATUS EESE HFE...

Page 32: ...C IEEE488 2 1987 If a character string contains a double quotation mark the double quotation mark is replaced by two double quotation marks This rule also applies to a single quotation mark within a c...

Page 33: ...next command may start before the execution of the previous command is completed For example if the next program message is transmitted when specifying the V div value and querying the result the resp...

Page 34: ...1 waveforms are being retrieved Otherwise it is stopped Example TRIGger MODE SINGle STARt PMT STATus CONDition PMT Read the response If bit 0 is 1 repeat this command until it becomes 1 WAVeform SEND...

Page 35: ...HIStogram x MEASure CURSor BASic ALL Turns ON OFF all basic items of the cursor of the accumulated histogram 5 36 ANALysis AHIStogram x MEASure CURSor BASic C x Queries all settings related to the cur...

Page 36: ...ems of the waveform parameter of the accumulated histogram or queries the current setting 5 41 ANALysis AHIStogram x MEASure PARameter CALCulation VALue x Queries the automated measured value of the c...

Page 37: ...ncy x VALue Queries the frequency value of the marker cursor of the FFT computation 5 46 ANALysis FFT x MEASure MARKer BASic POSition x NRf Sets the marker cursor position of the FFT computation or qu...

Page 38: ...ALue x Queries the measured value of the calculation item of the FFT computation 5 51 ANALysis FFT x RANGe Sets the measurement source window used in the FFT computation or queries the current setting...

Page 39: ...eform parameter measurement 5 56 ANALysis WPARameter x HISTogram MEASure PARameter Parameter STATe Turns ON OFF the histogram parameter of the waveform parameter measurement or queries the current set...

Page 40: ...the active level of the gate of the XY display or queries the current setting 5 61 ANALysis XY x GATE HYSTeresis x Sets the hysteresis of the gate of the XY display or queries the current setting 5 6...

Page 41: ...hannel or queries the current setting 5 68 CHANnel x PROBe Queries all settings related to the probe attenuation of the channel 5 68 CHANnel x PROBe MODE Sets the probe attenuation of the channel or q...

Page 42: ...tion item of the horizontal cursor or queries the current setting 5 73 CURSor HORizontal CALCulation VALue x Queries the measured value of the calculation item of the horizontal cursor 5 73 CURSor HOR...

Page 43: ...ies the measured value of the serial cursor 5 78 CURSor TYPE Sets the cursor type or queries the current setting 5 78 CURSor VERTical Queries all settings related to the vertical cursors 5 78 CURSor V...

Page 44: ...2 DISPlay ACCumulate PERSistence COUNt Sets the persistence count or queries the current setting 5 82 DISPlay ACCumulate PERSistence MODE Sets the persistence mode or queries the current setting 5 82...

Page 45: ...ATE x Queries the date time when the setup data was saved to the internal memory 5 87 FILE INTernal STORe SETup EXECute Executes the saving of the setup data to the internal memory This is an overlap...

Page 46: ...te Executes the GO NO GO determination This is an overlap command 5 92 GONogo LOGic Sets the GO NO GO determination logic or queries the current setting 5 92 GONogo MODE Sets the GO NO GO determinatio...

Page 47: ...nation or queries the current setting 5 96 GONogo ZPARameter SELect x PARameter MEASure STATistics Sets the statistical value of the measure determination or queries the current setting 5 97 GONogo ZP...

Page 48: ...01 HISTory Group HISTory Queries all settings related to the history function 5 102 HISTory CURRent Queries all settings related to the history function of the current waveform CH1 to 4 M1 to 8 5 102...

Page 49: ...meter MEASure TRACe x Queries all settings related to the trace of the measure search 5 107 HISTory CURRent SEARch SELect x PARameter MEASure TRACe x AREA x Queries all settings related to the area of...

Page 50: ...or queries the current setting 5 112 INITialize Group INITialize EXECute Execute the initialization 5 113 INITialize UNDO Cancels the initialization that was executed 5 113 MATH Group MATH x Queries...

Page 51: ...ubtraction 5 118 MATH x MINus RESCaling AVALue Sets rescaling coefficient A of the subtraction or queries the current setting 5 118 MATH x MINus RESCaling BVALue Sets rescaling offset B of the subtrac...

Page 52: ...inuous RESTart Restarts the continuous statistical processing 5 123 MEASure CYCLe Queries all settings related to the cycle statistical processing 5 123 MEASure CYCLe ABORt Aborts the execution of the...

Page 53: ...eries the current setting 5 129 MEASure TRACe x AREA x DPRoximal Queries all settings related to the distal and proximal values 5 129 MEASure TRACe x AREA x DPRoximal MODE Sets the unit of the distal...

Page 54: ...5 134 SEARch x SPATtern SETup Queries all settings related to setup of the serial pattern search 5 134 SEARch x SPATtern SETup BITRate Sets the bit rate of the serial pattern search or queries the cur...

Page 55: ...SYSTem FORMat SDELete EXECute Sure Delete Clears and formats the internal memory 5 142 SYSTem LANGuage Sets the message language or queries the current setting 5 142 SYSTem MFSize Sets the menu font s...

Page 56: ...ted in error 5 146 TELecomtest MMODe Turns ON OFF the computed waveform or queries the current setting 5 147 TELecomtest TRACe Sets the source trace of the telecom test or queries the current setting...

Page 57: ...154 TRIGger EINTerval EVENt x CANBus DATA SIGN Sets the sign of the CAN bus signal trigger data or queries the current setting 5 155 TRIGger EINTerval EVENt x CANBus IDEXt Queries all settings related...

Page 58: ...current setting 5 160 TRIGger EINTerval EVENt x CANBus RECessive Sets the recessive level bus level of the CAN bus signal trigger or queries the current setting 5 160 TRIGger EINTerval EVENt x CANBus...

Page 59: ...pattern of the I2 C bus trigger or queries the current setting 5 165 TRIGger EINTerval EVENt x I2CBus DATA HEXA x Sets the data of the I2 C bus trigger in hexadecimal notation 5 166 TRIGger EINTerval...

Page 60: ...erval EVENt x SPATtern DATA SOURce Sets the data trace of the serial pattern trigger or queries the current setting 5 170 TRIGger EINTerval EVENt x SPATtern HEXA Sets the pattern of the serial pattern...

Page 61: ...ted to the event interval trial 5 176 TRIGger EINTerval TRY MODE Sets the trial mode or queries the current setting 5 176 TRIGger EINTerval TRY SELect Sets the source event of the trial mode or querie...

Page 62: ...notation or queries the current setting 5 182 TRIGger ENHanced CANBus IDOR ID x IDSTd Queries all settings related to the ID of each standard format of the OR condition of the CAN bus signal trigger 5...

Page 63: ...setting 5 187 TRIGger ENHanced I2CBus DATA HEXA x Sets the data of the I2 C bus trigger in hexadecimal notation 5 187 TRIGger ENHanced I2CBus DATA MODE Enables Disables the data conditions of the I2...

Page 64: ...pattern trigger or queries the current setting 5 191 TRIGger ENHanced SPATtern PATTern Sets the pattern of the serial pattern trigger in binary notation or queries the current setting 5 191 TRIGger E...

Page 65: ...ty Sets the UART signal trigger polarity or queries the current setting 5 195 TRIGger ENHanced UART SOURce Sets the UART signal trigger source or queries the current setting 5 195 TRIGger ENHanced UAR...

Page 66: ...eries the current setting 5 200 WAVeform RECord MINimum Queries the minimum record number of the history of the target channel 5 201 WAVeform SEND Queries the waveform data specified by WAVeform TRACe...

Page 67: ...andard Event Status Register Queries the standard event register and clears the register 5 204 IDN IDeNtify Queries the instrument model 5 204 LRN LeaRN Queries collectively the current settings of th...

Page 68: ...ACQUIRE HRMODE 0 INTERLEAVE 0 INTERPOLATE 1 MODE NORMAL REPETITIVE 0 RLENGTH 12500 ACQuire AVERage Function Queries all settings related to averaging and the waveform acquisition count Syntax ACQuire...

Page 69: ...gram x HORizontal Function Sets the horizontal range of the accumulated histogram or queries the current setting Syntax ANALysis AHIStogram x HORizontal NRf NRf ANALysis AHIStogram x HORizontal x 1 or...

Page 70: ...TE 1 ANALYSIS AHISTOGRAM1 MEASURE PARAMETER AREA1 SDINTEG STATE 1 ANALysis AHIStogram x MEASure CURSor Function Queries all settings related to cursor measurement of the accumulated histogram Syntax A...

Page 71: ...DC x 1 or 2 Example ANALYSIS AHISTOGRAM1 MEASURE CURSOR BASIC DC ANALYSIS AHISTOGRAM1 MEASURE CURSOR BASIC DC STATE 1 ANALysis AHIStogram x MEASure CURSor BASic DC STATe Function Turns ON OFF the mea...

Page 72: ...on VALue x x of AHIStogram x 1 or 2 x of VALue x 1 to 4 Example ANALYSIS AHISTOGRAM1 MEASURE CURSOR CALCULATION VALUE1 ANALYSIS AHISTOGRAM1 MEASURE CURSOR CALCULATION VALUE1 1 000E 00 ANALysis AHIStog...

Page 73: ...Sure PARameter x 1 or 2 Example ANALYSIS AHISTOGRAM1 MEASURE PARAMETER ANALYSIS AHISTOGRAM1 MEASURE PARAMETER AREA1 MAXIMUM STATE 1 ANALYSIS AHISTOGRAM1 MEASURE PARAMETER AREA1 MEAN STATE 1 ANALYSIS A...

Page 74: ...r 2 x of AREA x 1 or 2 Example ANALYSIS AHISTOGRAM1 MEASURE PARAMETER AREA1 ALL ON ANALysis AHIStogram x MEASure PARameter AREA x Parameter Function Queries all settings related to the waveform parame...

Page 75: ...eter CALCulation DEFine x Function Sets the equation of the calculation items of the waveform parameter of the accumulated histogram or queries the current setting Syntax ANALysis AHIStogram x MEASure...

Page 76: ...ODE HORizontal VERTical ANALysis AHIStogram x MODE x 1 or 2 Example ANALYSIS AHISTOGRAM1 MODE HORIZONTAL ANALYSIS AHISTOGRAM1 MODE ANALYSIS AHISTOGRAM1 MODE HORIZONTAL ANALysis AHIStogram x TRACe Func...

Page 77: ...x 1 or 2 Example ANALYSIS FFT1 HORIZONTAL ANALYSIS FFT1 HORIZONTAL CSPAN CENTER 1 000E 00 SPAN 1 000E 00 ANALYSIS FFT1 HORIZONTAL LRIGHT RANGE 2 000E 00 1 000E 00 ANALYSIS FFT1 HORIZONTAL MODE AUTO A...

Page 78: ...1 LENGTH 2500 ANALYSIS FFT1 LENGTH ANALYSIS FFT1 LENGTH 2500 ANALysis FFT x MAXHold Function Turns ON OFF the maximum value hold function of the FFT computation or queries the current setting Syntax A...

Page 79: ...RE MARKER BASIC POSITION2 2 000E 00 V1 STATE 1 ANALYSIS FFT1 MEASURE MARKER BASIC V2 STATE 1 ANALysis FFT x MEASure MARKer BASic ALL Function Turns ON OFF all basic items of the marker cursor of the F...

Page 80: ...1 or 2 Example ANALYSIS FFT1 MEASURE MARKER BASIC FREQUENCY1 ANALYSIS FFT1 MEASURE MARKER BASIC FREQUENCY1 STATE 1 ANALysis FFT x MEASure MARKer BASic FREQuency x STATe Function Turns ON OFF the frequ...

Page 81: ...re MARKer CALCulation x 1 or 2 Example ANALYSIS FFT1 MEASURE MARKER CALCULATION ANALYSIS FFT1 MEASURE MARKER CALCULATION DEFINE1 V F1 DEFINE2 V F2 DEFINE3 V F1 D EFINE4 V F2 STATE1 1 STATE2 1 STATE3 1...

Page 82: ...E 00 0 000E 00 RANGE2 1 000E 00 0 000E 00 V1 STATE 1 ANALYSIS FFT1 MEASURE PEAK BASIC V2 STATE 1 ANALYSIS FFT1 MEASURE PEAK CALCULATION DEFINE1 V P1 DEFINE2 V P2 DEFINE3 V P1 DEFINE4 V P2 STATE1 1 STA...

Page 83: ...ALYSIS FFT1 MEASURE PEAK BASIC DV STATE ON ANALYSIS FFT1 MEASURE PEAK BASIC DV STATE ANALYSIS FFT1 MEASURE PEAK BASIC DV STATE 1 ANALysis FFT x MEASure PEAK BASic DV VALue Function Queries the power v...

Page 84: ...s FFT x MEASure PEAK BASic V x VALue Function Queries the peak value of the FFT computation Syntax ANALysis FFT x MEASure PEAK BASic V x VALue x of FFT x 1 or 2 x of V x 1 or 2 Example ANALYSIS FFT1 M...

Page 85: ...nt setting Syntax ANALysis FFT x RPARt NRf ANALysis FFT x RPARt x 1 or 2 NRf 1 to 8 Example ANALYSIS FFT1 RPART 1 ANALYSIS FFT1 RPART ANALYSIS FFT1 RPART 1 ANALysis FFT x RPOSition Ref Position Functi...

Page 86: ...S WAIT1 100 ANALYSIS WAIT1 1 DescriptionIf the execution of the automated measurement completes within the timeout value 0 is returned if it is not complete or automated measurement is not being execu...

Page 87: ...Lysis WPARameter x HISTogram MEASure Function Queries all settings related to the automated measurement of the histogram display of the waveform parameter measurement Syntax ANALysis WPARameter x HIST...

Page 88: ...ITION ANALYSIS WPARAMETER1 HISTOGRAM MEASURE CURSOR C1 POSITION 1 000E 00 ANALysis WPARameter x HISTogram MEASure CURSor C x STATe Function Turns ON OFF the cursor on the histogram of the waveform par...

Page 89: ...ANALYSIS WPARAMETER1 HISTOGRAM MEASURE CURSOR LINKAGE ANALYSIS WPARAMETER1 HISTOGRAM MEASURE CURSOR LINKAGE 1 ANALysis WPARameter x HISTogram MEASure MODE Function Sets the automated measurement mode...

Page 90: ...ARameter Parameter VALue x 1 or 2 Parameter MEAN PEAK SD3integ SDEViation SDINteg Example The following is an example for the average value ANALYSIS WPARAMETER1 HISTOGRAM MEASURE PARAMETER MEAN VALUE...

Page 91: ...o the area of the waveform parameter measurement Syntax ANALysis WPARameter x TRACe x AREA x x of WPARameter x 1 or 2 x of TRACe x 1 to 8 x of AREA x 1 or 2 Example ANALYSIS WPARAMETER1 TRACE1 AREA1 A...

Page 92: ...ample ANALYSIS WPARAMETER1 TREND MEASURE ANALYSIS WPARAMETER1 TREND MEASURE CURSOR C1 POSITION 1 000E 00 STATE 1 ANALYSIS WPARAMETER1 TREND MEASURE CURSOR C2 POSITION 2 000E 00 STATE 1 ANALYSIS WPARAM...

Page 93: ...measurement Syntax ANALysis WPARameter x TRENd MEASure CURSor C x VALue x of WPARameter x 1 or 2 x of C x 1 or 2 Example ANALYSIS WPARAMETER1 TREND MEASURE CURSOR C1 VALUE ANALYSIS WPARAMETER1 TREND M...

Page 94: ...L1 1 000E 00 LEVEL2 1 000E 00 LEVEL3 1 000E 00 LEVEL4 1 000E 00 LEVEL5 1 000E 00 LEVEL6 1 000E 00 LEVEL7 1 000E 00 LEVEL8 1 000E 00 TRACE 1 ANALysis WPARameter x TRENd MEASure CURSor LINKage Function...

Page 95: ...SIS XY1 GATE LEVEL1 1 000E 00 ANALysis XY x GATE TRACe Function Sets the gate trace of the XY display or queries the current setting Syntax ANALysis XY x GATE TRACe NRf OFF ANALysis XY x GATE TRACe x...

Page 96: ...Sition NRf ANALysis XY x MEASure CURSor Y x POSition x of XY x 1 or 2 x of Y x 1 or 2 NRf 4 to 4 div Example ANALYSIS XY1 MEASURE CURSOR Y1 POSITION 1 ANALYSIS XY1 MEASURE CURSOR Y1 POSITION ANALYSIS...

Page 97: ...W MAIN ANALYSIS XY1 WINDOW ANALYSIS XY1 WINDOW MAIN ANALysis XY x MEASure CURSor Y x VALue Function Queries the voltage value at the vertical cursor of the XY display Syntax ANALysis XY x MEASure CURS...

Page 98: ...XTRace x 1 or 2 NRf 1 to 8 Example ANALYSIS XY1 XTRACE 1 ANALYSIS XY1 XTRACE ANALYSIS XY1 XTRACE 1 ANALysis XY x YTRace Function Sets the Y axis trace of the XY display or queries the current setting...

Page 99: ...1 2 3 4 5 6 App Index 5 4 ASETup Group ASETup EXECute Function Execute auto setup Syntax ASETup EXECute Example ASETUP EXECUTE ASETup UNDO Function Cancels auto setup that has been executed Syntax ASE...

Page 100: ...E MODE AUTO CALibrate EXECute Function Executes calibration Syntax CALibrate EXECute Example CALIBRATE EXECUTE CALibrate MODE Function Turns ON OFF the auto calibration or queries the current setting...

Page 101: ...DE x 1 to 4 Example CHANNEL1 LABEL MODE ON CHANNEL1 LABEL MODE CHANNEL1 LABEL MODE 1 CHANnel x Function Queries all settings related to the channel Syntax CHANnel x x 1 to 4 Example CHANNEL1 CHANNEL1...

Page 102: ...ple CHANNEL1 VDIV 5V CHANNEL1 VDIV CHANNEL1 VDIV 5 000E 00 CHANnel x OCANcel Function Turns ON OFF the offset cancel of the channel or queries the current setting Syntax CHANneL x OCANcel Boolean CHAN...

Page 103: ...ion Clears accumulated waveforms Syntax CLEar ACCumulate Example CLEAR ACCUMULATE CLEar HISTory Function Clears history waveforms Syntax CLEar HISTory Example CLEAR HISTORY CLEar SNAP Function Clears...

Page 104: ...printer operation not complete When bit 6 ACS 1 Access to the medium not complete When bit 8 HST 1 History search execution not complete When bit 11 SCH 1 Search execution not complete COMMunicate Fun...

Page 105: ...s and cleared when it is read COMMunicate VERBose Function Sets whether to return the response to a query using full spelling example CHANNEL1 VOLTAGE PROBE 10 or using abbreviation example CHAN PROB...

Page 106: ...r HORizontal BASic LINKage Example CURSOR HORIZONTAL BASIC LINKAGE ON CURSOR HORIZONTAL BASIC LINKAGE CURSOR HORIZONTAL BASIC LINKAGE 1 CURSor Function Queries all settings related to the cursor measu...

Page 107: ...ALUE 1 000E 00 CURSor HORizontal CALCulation Function Queries all settings related to calculation items of the horizontal cursors Syntax CURSor HORizontal CALCulation Example CURSOR HORIZONTAL CALCULA...

Page 108: ...V3 DEFINE4 V4 STATE1 0 STATE2 0 STATE3 0 STATE4 0 CURSor MARKer CALCulation ALL Function Turns ON OFF all calculation items of the marker cursors Syntax CURSor MARKer CALCulation ALL Boolean Example C...

Page 109: ...of CM x 1 to 4 x of DV x 1 to 4 Example CURSOR MARKER CM1 DV2 CURSOR MARKER CM1 DV2 STATE 1 CURSor MARKer CM x DV x STATe Function Turns ON OFF the V measurement of the maker cursor or queries the cu...

Page 110: ...tion Queries the voltage value at the marker cursor position Syntax CURSor MARKer CM x V VALue x 1 to 4 Example CURSOR MARKER CM1 V VALUE CURSOR MARKER CM1 V VALUE 0 000E 00 CURSor MARKer FORM Functio...

Page 111: ...1 FORMAT HEXA CURSor SERial SCURsor x HYSTeresis Function Sets the hysteresis of the serial cursor or queries the current setting Syntax CURSor SERial SCURsor x HYSTeresis NRf CURSor SERial SCURsor x...

Page 112: ...LINKage Boolean CURSor VERTical BASic LINKage Example CURSOR VERTICAL BASIC LINKAGE ON CURSOR VERTICAL BASIC LINKAGE CURSOR VERTICAL BASIC LINKAGE 1 CURSor SERial SCURsor x TRACE Function Sets the tr...

Page 113: ...r 2 Example CURSOR VERTICAL BASIC T1 JUMP Z1 CURSor VERTical BASic T x POSition Function Sets the vertical cursor position or queries the current setting Syntax CURSor VERTical BASic T x POSition NRf...

Page 114: ...CURSOR VT BASIC V8 STATE 1 CURSOR VT CALCULATION DEFINE1 T1 DEFINE2 V C1 DEFINE3 V C2 DEFINE4 V C3 STATE1 0 STATE2 0 STATE3 0 STATE4 0 CURSor VT BASic Function Queries all settings related to basic i...

Page 115: ...on ALL Function Turns ON OFF all calculation items of the VT cursor Syntax CURSor VT CALCulation ALL Boolean Example CURSOR VT CALCULATION ALL ON CURSor VT CALCulation DEFine x Function Sets the equat...

Page 116: ...STENCE TIME 1S DISPLAY ACCUMULATE PERSISTENCE TIME DISPLAY ACCUMULATE PERSISTENCE TIME 1 000E 00 DISPlay Function Queries all settings related to the display Syntax DISPlay Example DISPLAY DISPLAY ACC...

Page 117: ...ANNEL2 BGREEN CHANNEL3 CYAN CHANNEL4 DBLUE MATH1 GRAY MATH2 GREEN MATH3 LBLUE MATH4 LGREEN REFERENCE1 MAGENTA REFERENCE2 MGREEN REFERENCE3 ORANGE REFERENCE4 PINK DISPlay COLor CHANnel x MATH x REFeren...

Page 118: ...ng Example DISPLAY MAPPING DISPLAY MAPPING MODE AUTO TRACE1 1 TRACE2 1 TRACE3 1 TRACE4 1 TRACE5 1 TRACE6 1 TRACE7 1 TRACE8 1 DISPlay MAPPing MODE Function Sets the waveform mapping mode for the split...

Page 119: ...on Queries the free disk space in bytes on the specified storage medium Syntax FILE DIRectory FREE Example FILE DIRECTORY FREE FILE DIRECTORY FREE 65536 Description Returns the size of the current dir...

Page 120: ...RNAL RECALL SETUP EXECUTE 1 FILE INTernal STORe Function Queries all settings related to the saving to the internal memory Syntax FILE INTernal STORe Example FILE INTERNAL STORE FILE INTERNAL STORE BI...

Page 121: ...DATE x Function Queries the date time when the setup data was saved to the internal memory Syntax FILE INTernal STORe SETup DATE x x 1 to 12 Example FILE INTERNAL STORE SETUP DATE1 FILE INTERNAL STOR...

Page 122: ...1 FILE SAVE COMMENT THIS IS TEST DMEMORY TRACE 1 FILE SAVE FFT ANALYSIS 1 FILE SAVE FLOAT COMPRESSION DECIMATION HISTORY ONE LENGTH 2500 TRACE 1 FILE SAVE NAME DL9000 SBUS ANALYSIS 1 FILE SAVE ZWAVE...

Page 123: ...ARY COMPRESSION FILE SAVE BINARY COMPRESSION DECIMATION FILE SAVE ASCii BINary FLOat HISTory Function Sets whether to save the entire data or the selected data of specific data or queries the current...

Page 124: ...MORY TRACE 1 FILE SAVE NAME Function Sets the name of the data file to be saved or queries the current setting Syntax FILE SAVE NAME Filename FILE SAVE NAME Example FILE SAVE NAME DL9000 FILE SAVE NAM...

Page 125: ...o ACTion MAIL MODE Example GONOGO ACTION MAIL MODE ON GONOGO ACTION MAIL MODE GONOGO ACTION MAIL MODE 1 GONogo Function Queries all settings related to GO NO GO determination Syntax GONogo Example GON...

Page 126: ...UNT 1 GONogo SCONdition Stop Condition Function Queries all settings related to the determination termination condition Syntax GONogo SCONdition Example GONOGO SCONDITION GONOGO SCONDITION NGCOUNT 1 S...

Page 127: ...e condition Syntax GONogo TELecomtest SELect x MASK x 1 to 4 Example GONOGO TELECOMTEST SELECT1 MASK GONOGO TELECOMTEST SELECT1 MASK ELEMENT1 PSPCOUNT 2 000E 00 1 000E 00 GONogo TELecomtest SELect x M...

Page 128: ...R SELECT1 MODE PARAMETER PARAMETER CATEGORY FFT FFT1 CALCULATION1 0 000E 00 1 000E 00 GONOGO ZPARAMETER SELECT1 RECTANGLE HORIZONTAL 0 000E 00 1 000E 00 VERTICAL 0 000E 00 1 000E 00 GONOGO ZPARAMETER...

Page 129: ...Fr equency GONogo ZPARameter SELect x PARameter FFT x PEAK DFREquency x of SELect x 1 to 4 x of FFT x 1 or 2 Frequency See the DL9000 User s Manual Example GONOGO ZPARAMETER SELECT1 PARAMETER FFT1 PE...

Page 130: ...the upper and lower limits of the peak voltage of the FFT determination or queries the current setting Syntax GONogo ZPARameter SELect x PARameter FFT x PEAK V x NRf NRf GONogo ZPARameter SELect x PA...

Page 131: ...M 1 2 GONOGO ZPARAMETER SELECT1 PARAMETER MEASURE TRACE1 AREA1 TYPE MAXIMUM GONOGO ZPARAMETER SELECT1 PARAMETER MEASURE TRACE1 AREA1 TYPE MAXIMUM 2 000E 00 1 000E 00 DescriptionThis command applies to...

Page 132: ...used in the rectangle determination or queries the current setting Syntax GONogo ZPARameter SELect x RECTangle HORizontal NRf NRf GONogo ZPARameter SELect x RECTangle HORizontal x 1 to 4 NRf 5 to 5 di...

Page 133: ...zone waveform that is currently displayed GONogo ZPARameter SELect x WAVE EDIT x WHOLe Function Sets the editing of the entire zone of the waveform zone Syntax GONogo ZPARameter SELect x WAVE EDIT x W...

Page 134: ...s related to the saving of file output Syntax HCOPy FILE SAVE Example HCOPY FILE SAVE HCOPY FILE SAVE ANAMING DATE CDIRECTORY Flash Mem DIR1 DIR2 NAME SAMPLE HCOPy Hard COPY Function Queries all setti...

Page 135: ...ble To specify an absolute path enter a backslash at the front of the path Relative path to higher level directories is not allowed HCOPy FILE SAVE NAME Function Sets the save destination file name or...

Page 136: ...t DISPlay Function Sets the start number and end number of the display record of the history waveform or queries the current setting Syntax HISTory CURRent DISPlay NRf NRf HISTory CURRent DISPlay NRf...

Page 137: ...rm Syntax HISTory CURRent RECord MINimum Example HISTORY CURRENT RECORD MINIMUM HISTORY CURRENT RECORD 1 DescriptionSpecifying MINimum sets the record to the minimum record number HISTory CURRent REPL...

Page 138: ...Tory CURRent SEARch LOGic AND OR HISTory CURRent SEARch LOGic Example HISTORY CURRENT SEARCH LOGIC AND HISTORY CURRENT SEARCH LOGIC HISTORY CURRENT SEARCH LOGIC AND HISTory CURRent SEARch RESet Functi...

Page 139: ...x of SELect x 1 to 4 x of FFT x 1 or 2 Example HISTORY CURRENT SEARCH SELECT1 PARAMETER FFT1 HISTORY CURRENT SEARCH SELECT1 PARAMETER FFT1 CALCULATION1 2 000E 00 1 000E 00 HISTory CURRent SEARch SELec...

Page 140: ...mits of the peak frequency of the FFT search or queries the current setting Syntax HISTory CURRent SEARch SELect x PARameter FFT x PEAK FREquency x Frequency Frequency HISTory CURRent SEARch SELect x...

Page 141: ...TORY CURRENT SEARCH SELECT1 PARAMETER MEASURE TRACE1 HISTORY CURRENT SEARCH SELECT1 PARAMETER MEASURE TRACE1 AREA1 TYPE BURST 2 000E 00 1 000E 00 HISTory CURRent SEARch SELect x PARameter MEASure TRAC...

Page 142: ...RCH SELECT1 RECTANGLE HORIZONTAL 2 000E 00 1 000E 00 HISTory CURRent SEARch SELect x PARameter MEASure TRACe x AREA x TYPE Parameter Function Sets the upper and lower limits of the waveform parameter...

Page 143: ...SELect x 1 to 4 x of EDIT x 1 to13 1 to 8 are traces 9 to 12 are internal memories 13 is the zone waveform that is currently displayed NRf 0 to 5 div left and right 0 to 8 div up and down In the order...

Page 144: ...EPLAY SPEED 1 HISTory REFerence x DMODe Display Mode Function Sets the display mode of the history waveform of the reference or queries the current setting Syntax HISTory REFerence x DMODe ACOLor AHTo...

Page 145: ...RY REFERENCE1 REPLAY SPEED HISTORY REFERENCE1 REPLAY SPEED 1 HISTory REFerence x REPLay STARt Function Starts the replay of the history waveform of the reference Syntax HISTory REFerence x REPLay STAR...

Page 146: ...at Example IMAGE FORMAT BMP IMAGE FORMAT IMAGE FORMAT BMP IMAGe SEND Function Queries the screen image data Syntax IMAGe SEND Example IMAGE SEND 6 number of bytes 6 digits data byte sequence block dat...

Page 147: ...x 5 16 INITialize Group INITialize EXECute Function Execute the initialization Syntax INITialize EXECute Example INITIALIZE EXECUTE INITialize UNDO Function Cancels the initialization that was execute...

Page 148: ...DELay TIME x 1 to 8 Time See the DL9000 User s Manual Example MATH1 FILTER DELAY TIME 1S MATH1 FILTER DELAY TIME MATH1 FILTER DELAY TIME 1 000E 00 MATH x Function Queries all settings related to the c...

Page 149: ...to 8 Example MATH1 FILTER IIR LOWPASS MATH1 FILTER IIR LOWPASS COFF 10 00E 06 MATH x FILTer IIR LOWPass COFF Function Sets the cutoff frequency of the IIR low pass filter computation or queries the cu...

Page 150: ...AVALUE MATH1 INTEGRAL PSCALING AVALUE 1 000E 00 MATH x INTegral PSCaling BVALue Function Sets pre scaling offset B of the integral computation or queries the current setting Syntax MATH x INTegral PS...

Page 151: ...he label display of the computed waveform or queries the current setting Syntax MATH x LABel MODE Boolean MATH x LABel MODE x 1 to 8 MATH x MINus Function Queries all settings related to the subtracti...

Page 152: ...ALING AVALUE MATH1 MULTIPLE RESCALING AVALUE 1 000E 00 MATH x MINus RESCaling Function Queries all settings related to the rescaling of the subtraction Syntax MATH x MINus RESCaling x 1 to 8 Example M...

Page 153: ...or 2 Example MATH1 PLUS PSCALING1 MATH1 PLUS PSCALING1 AVALUE 1 000E 00 BVALUE 0 000E 00 MATH x PLUS PSCaling x AVALue Function Sets pre scaling coefficient A of the addition or queries the current s...

Page 154: ...oltage and Current See the DL9000 User s Manual Example MATH1 SCALE SENSITIVITY 1 MATH1 SCALE SENSITIVITY MATH1 SCALE SENSITIVITY 1 000E 00 MATH x SELect Function Sets the display option or queries th...

Page 155: ...CONStant x NRf MATH x USERdefine CONStant x MATH x x 1 to 4 CONStant x x 1 to 4 NRf 1 0000E 31 to 1 0000E 31 Example MATH1 USERDEFINE CONSTANT1 1 MATH1 USERDEFINE CONSTANT1 MATH1 USERDEFINE CONSTANT1...

Page 156: ...ure Function Queries all settings related to the automated measurement of waveform parameters Syntax MEASure Example MEASURE MEASURE CALCULATION DEFINE1 MAX C1 DEFINE2 MIN C2 DEFINE3 HIGH C3 DEFINE4 L...

Page 157: ...previous statistical data MEASure CYCLe Function Queries all settings related to the cycle statistical processing Syntax MEASure CYCLe Example MEASURE CYCLE MEASURE CYCLE TRACE 1 MEASure CYCLe ABORt F...

Page 158: ...S 1 000E 00 LEVEL 0 000E 00 MEASURE THRESHOLD TRACE1 MODE AUTO ULOWER RANGE 1 000E 00 2 000E 00 DescriptionThis command is valid when the Parameter of MEASure TRACe x AREA x Parameter is not RISE or F...

Page 159: ...HRESHOLD TRACE1 MODE LHYSTERESIS DescriptionThis command is valid when the Parameter of MEASure TRACe x AREA x Parameter is not RISE or FALL MEASure THReshold TRACe x ULOWer Function Queries all setti...

Page 160: ...EASURE TRACE1 AREA1 RISE STATE 0 MEASURE TRACE1 AREA1 RMS STATE 0 MEASure TRACe x AREA x Function Queries all settings related to the area Syntax MEASure TRACe x AREA x x of TRACe x 1 to 8 x of AREA x...

Page 161: ...e The following is an example for the maximum value of trace 1 and area 1 MEASURE TRACE1 AREA1 MAXIMUM STATE ON MEASURE TRACE1 AREA1 MAXIMUM STATE MEASURE TRACE1 AREA1 MAXIMUM STATE 1 MEASure TRACe x...

Page 162: ...ERENCE COUNT 1 POLARITY FALL TRACE 1 MEASure TRACe x AREA x Parameter VALue Function Queries the automated measured value of the waveform parameter Syntax MEASure TRACe x AREA x Parameter VALue NRf x...

Page 163: ...to 8 x of AREA x 1 or 2 NRf 1 to 8 Example MEASURE TRACE1 AREA1 DELAY REFERENCE TRACE 1 MEASURE TRACE1 AREA1 DELAY REFERENCE TRACE MEASURE TRACE1 AREA1 DELAY REFERENCE TRACE 1 MEASure TRACe x AREA x D...

Page 164: ...unction Sets the method for detecting the High Low level for automated measurement of waveform parameters or queries the current setting Syntax MEASure TRACe x AREA x METHod AUTO HISTogram MAXMin MEAS...

Page 165: ...rence or queries the current setting Syntax REFerence x SVALue Boolean REFerence x SVALue x 1 to 4 Example REFERENCE1 SVALUE ON REFERENCE1 SVALUE REFERENCE1 SVALUE 1 REFerence x Function Queries all s...

Page 166: ...1 DECIMATION 1 SEARch x Function Queries all settings related to the search function Syntax SEARch x x 1 or 2 Example SEARCH1 SEARCH1 CLOCK SOURCE 1 POLARITY FALL SEARCH1 DECIMATION 1 HOLDOFF 0 000E 0...

Page 167: ...en SEARch x TYPE WIDTh and SEARch x WIDTh TYPE PSTAte SEARch x SELect Function Sets the detection waveform number of the search function and queries the position that corresponds to the detection wave...

Page 168: ...ATA ACTIVE HIGH TRACE 1 SEARCH1 SPATTERN SETUP PATTERN 1100 SEARch x SPATtern CLOCk MODE Function Enables Disables the clock of the serial pattern search or queries the current setting Syntax SEARch x...

Page 169: ...ate Function Sets the bit rate of the serial pattern search or queries the current setting Syntax SEARch x SPATtern SETup BITRate NRf SEARch x SPATtern SETup BITRate x 1 or 2 NRf 1 to 1G bps Example S...

Page 170: ...EARCH1 WIDTH TYPE SEARCH1 WIDTH TYPE PQUALIFY SEARch x TRACe x Function Queries all settings related to the search conditions of the trace Syntax SEARch x TRACe x x of SEARch x 1 or 2 x of TRACe x 1 t...

Page 171: ...5 137 IM 701310 17E Commands 1 2 3 4 5 6 App Index 5 21 SNAP Group SNAP Function Executes the snapshot Syntax SNAP Example SNAP...

Page 172: ...and wait 0 START only No wait 360000 to 1 10 ms unit wait time do not START and wait Example SSTART 100 SSTART 0 Description If the specified time period is positive data acquisition is started in th...

Page 173: ...5 139 IM 701310 17E Commands 1 2 3 4 5 6 App Index 5 23 STARt Group STARt Function Starts the waveform acquisition Syntax STARt Example START DescriptionUse STOP to stop the waveform acquisition...

Page 174: ...e STATUS SPOLL STATUS SPOLL 0 DescriptionThis command is dedicated to the Ethernet interface option STATus Function Queries all settings related to the communication status function Syntax STATus Exam...

Page 175: ...5 141 IM 701310 17E Commands 1 2 3 4 5 6 App Index 5 25 STOP Group STOP Function Stops the waveform acquisition Syntax STOP Example STOP DescriptionUse STARt to start the waveform acquisition...

Page 176: ...es the current setting Syntax SYSTem USBKeyboard ENGLish JAPanese SYSTem USBKeyboard Example SYSTEM USBKEYBOARD ENGLISH SYSTEM USBKEYBOARD SYSTEM USBKEYBOARD ENGLISH SYSTem Function Queries all settin...

Page 177: ...xample The following is an example for DBERate TELECOMTEST EYEPATTERN DBERATE TELECOMTEST EYEPATTERN DBERATE STATE 1 Description For the relationship between communication commands and parameters used...

Page 178: ...ueries the current setting Syntax TELecomtest EYEPattern Parameter STATe Boolean TELecomtest EYEPattern Parameter STATe Parameter DBERate EHEight EWIDth FALL JITTer x PCROssing PDUTycycle QFACtor RISE...

Page 179: ...x PWCount x 1 to 4 Example TELECOMTEST MASK ELEMENT1 PWCOUNT TELECOMTEST MASK ELEMENT1 PWCOUNT STATE 1 TELecomtest MASK Function Queries all settings related to the mask test Syntax TELecomtest MASK E...

Page 180: ...lean TELecomtest MASK ELEMent x SPCount STATe x 1 to 4 Example TELECOMTEST MASK ELEMENT1 SPCOUNT STATE ON TELECOMTEST MASK ELEMENT1 SPCOUNT STATE TELECOMTEST MASK ELEMENT1 SPCOUNT STATE 1 TELecomtest...

Page 181: ...to 8 Example TELECOMTEST TRACE 1 TELECOMTEST TRACE TELECOMTEST TRACE 1 TELecomtest TRANge Time Range Function Sets the measurement range of the telecom test or queries the current setting Syntax TELe...

Page 182: ...le RATE Function Queries the sample rate or queries the current setting Syntax TIMebase SRATe Example TIMEBASE SRATE TIMEBASE SRATE 125 0E 06 TIMebase TDIV Function Sets the T div value or queries the...

Page 183: ...IGGER TRIGGER ACTION ACQCOUNT 1 BUZZER 0 HCOPY 1 MAIL INTERVAL OFF MODE 0 TRIGGER ACTION MODE ACONDITION SAVE 1 TRIGGER TYPE EICYCLE CLOCK SOURCE 1 POLARITY RISE TRIGGER DELAY EDGECOUNT COUNT 1 TRIGGE...

Page 184: ...ock channel Syntax TRIGger CLOCk Example TRIGGER CLOCK TRIGGER CLOCK SOURCE 1 POLARITY RISE TRIGger CLOCk POLarity Function Sets the polarity of the clock channel or queries the current setting Syntax...

Page 185: ...rent setting Syntax TRIGger DELay TYPE BYTime EDGecount FEADelay TRIGger DELay TYPE Example TRIGGER DELAY TYPE BYTIME TRIGGER DELAY TYPE TRIGGER DELAY TYPE BYTIME TRIGger EINTerval Function Queries al...

Page 186: ...L EVENT1 SPATTERN PATTERN 1100110111101111 DescriptionEVENt2 is valid when TRIGger TYPE EIDelay EISequence TRIGger EINTerval EVENt x CANBus Function Queries all settings related to the CAN bus signal...

Page 187: ...r data Syntax TRIGger EINTerval EVENt x CANBus DATA x 1 or 2 Example TRIGGER EINTERVAL EVENT1 CANBUS DATA TRIGGER EINTERVAL EVENT1 CANBUS DATA BORDER BIG CONDITION DONTCARE DATA1 0 0000000E 00 DATA2 2...

Page 188: ...TA DLC x 1 or 2 NRf 0 to 8 Example TRIGGER EINTERVAL EVENT1 CANBUS DATA DLC 0 TRIGGER EINTERVAL EVENT1 CANBUS DATA DLC TRIGGER EINTERVAL EVENT1 CANBUS DATA DLC 0 TRIGger EINTerval EVENt x CANBus DATA...

Page 189: ...EXT PATTERN 1100101101110000 1110111011111 TRIGger EINTerval EVENt x CANBus IDEXt HEXA Function Sets the ID of the extended format of the CAN bus signal trigger in hexadecimal notation Syntax TRIGger...

Page 190: ...ER EINTERVAL EVENT1 CANBUS IDOR ID3 ACK DONTCARE DATA BORDER BIG CONDITION DONTCARE DATA1 0 0000000E 00 DATA2 255 00000E 00 DLC 8 TRIGger EINTerval EVENt x CANBus IDOR ID x Function Queries all settin...

Page 191: ...1 CANBUS IDOR ID1 DATA CONDITION TRIGGER EINTERVAL EVENT1 CANBUS IDOR ID1 DATA CONDITION BETWEEN TRIGger EINTerval EVENt x CANBus IDOR ID x DATA DATA x Function Sets comparison data of each data of th...

Page 192: ...EINTERVAL EVENT1 CANBUS IDOR ID1 DATA PATTERN 11011111 TRIGGER EINTERVAL EVENT1 CANBUS IDOR ID1 DATA PATTERN TRIGGER EINTERVAL EVENT1 CANBUS IDOR ID1 DATA PATTERN 11011111 TRIGger EINTerval EVENt x CA...

Page 193: ...VENT1 CANBUS IDOR ID1 IDSTD TRIGGER EINTERVAL EVENT1 CANBUS IDOR ID1 IDSTD PATTERN 00011111101 TRIGger EINTerval EVENt x CANBus IDOR ID x IDSTd HEXA Function Sets the ID of each standard format of the...

Page 194: ...TRIGger EINTerval EVENt x CANBus IDSTd PATTern Function Sets the ID of the standard format of the CAN bus signal trigger in binary notation or queries the current setting Syntax TRIGger EINTerval EVEN...

Page 195: ...EINTerval EVENt x CLOCk x 1 or 2 Example TRIGGER EINTERVAL EVENT1 CLOCK TRIGGER EINTERVAL EVENT1 CLOCK SOURCE 1 POLARITY FALL TRIGger EINTerval EVENt x CLOCk POLarity Function Sets the polarity of the...

Page 196: ...YPE EQUalify TRIGger EINTerval EVENt x I2CBus Function Queries all settings related to the I2 C bus trigger of the event Syntax TRIGger EINTerval EVENt x I2CBus x 1 or 2 Example TRIGGER EINTERVAL EVEN...

Page 197: ...settings related to the 7 bit address of the I2 C bus trigger Syntax TRIGger EINTerval EVENt x I2CBus ADATa BIT7ADdress x 1 or 2 Example TRIGGER EINTERVAL EVENT1 I2CBUS ADATA BIT7ADDRESS TRIGGER EINTE...

Page 198: ...the Sub address of the 7 bit Sub address of the I2 C bus trigger Syntax TRIGger EINTerval EVENt x I2CBus ADATa BIT7APsub SADDress x 1 or 2 Example TRIGGER EINTERVAL EVENT1 I2CBUS ADATA BIT7APSUB SADD...

Page 199: ...er EINTerval EVENt x I2CBus DATA BYTE Function Sets the number of data bytes of the I2 C bus trigger or queries the current setting Syntax TRIGger EINTerval EVENt x I2CBus DATA BYTE NRf TRIGger EINTer...

Page 200: ...TTERN1 10101011 TRIGGER EINTERVAL EVENT1 I2CBUS DATA PATTERN1 TRIGGER EINTERVAL EVENT1 I2CBUS DATA PATTERN1 10101011 TRIGger EINTerval EVENt x I2CBus DATA PMODe Function Sets the pattern comparison st...

Page 201: ...RIGGER EINTERVAL EVENT1 I2CBUS GCALL BIT7MADDRESS PATTERN 1010101 TRIGGER EINTERVAL EVENT1 I2CBUS GCALL BIT7MADDRESS PATTERN TRIGGER EINTERVAL EVENT1 I2CBUS GCALL BIT7MADDRESS PATTERN 1010101 TRIGger...

Page 202: ...EINTERVAL EVENT1 I2CBUS NAIGNORE SBYTE 1 TRIGger EINTerval EVENt x I2CBus SBHSmode Function Queries all settings related to the start byte and high speed mode of the I2 C bus trigger Syntax TRIGger E...

Page 203: ...lid when TRIGger EINTerval EVENt x SPATtern CLOCk MODE OFF TRIGger EINTerval EVENt x SPATtern CLEar Function Clears the entire pattern of the serial pattern trigger to don t care Syntax TRIGger EINTer...

Page 204: ...IGH SOURCE 1 TRIGger EINTerval EVENt x SPATtern DATA ACTive Function Sets the active level of the data of the serial pattern trigger or queries the current setting Syntax TRIGger EINTerval EVENt x SPA...

Page 205: ...gger in binary notation or queries the current setting Syntax TRIGger EINTerval EVENt x SPATtern PATTern String TRIGger EINTerval EVENt x SPATtern PATTern x 1 or 2 String Up to 128 characters by combi...

Page 206: ...ger Syntax TRIGger EINTerval EVENt x SPIBus CS x 1 or 2 Example TRIGGER EINTERVAL EVENT1 SPIBUS CS TRIGGER EINTERVAL EVENT1 SPIBUS CS ACTIVE HIGH SOURCE 1 TRIGger EINTerval EVENt x SPIBus CS ACTive Fu...

Page 207: ...2 NRf 0 to 9999 Example TRIGGER EINTERVAL EVENT1 SPIBUS DATA1 DPOSITION 1 TRIGGER EINTERVAL EVENT1 SPIBUS DATA1 DPOSITION TRIGGER EINTERVAL EVENT1 SPIBUS DATA1 DPOSITION 1 TRIGger EINTerval EVENt x SP...

Page 208: ...alid when TRIGger EINTerval EVENt x TYPE I2CBus SPATtern IN OUT is valid when TRIGger EINTerval EVENt x TYPE EQUalify PQUalify PSTAt e STATe and TRIGger SOURce CHANnel x WINDow ON HIGH LOW is valid wh...

Page 209: ...erval EVENt x TYPE PSTAte TRIGger EINTerval EVENt x WIDTh SOURce Function Sets the trigger source of the pulse width trigger or queries the current setting Syntax TRIGger EINTerval EVENt x WIDTh SOURc...

Page 210: ...ings related to the enhanced trigger Syntax TRIGger ENHanced Example TRIGGER ENHANCED TRIGGER ENHANCED I2CBUS ADATA BIT10ADDRESS PATTERN 00011111101 TRIGGER ENHANCED I2CBUS ADATA BIT7ADDRESS PATTERN 1...

Page 211: ...ONTcare NONack TRIGger ENHanced CANBus ACK Example TRIGGER ENHANCED CANBUS ACK ACK TRIGGER ENHANCED CANBUS ACK TRIGGER ENHANCED CANBUS ACK ACK TRIGger ENHanced CANBus BRATe Function Sets the bit rate...

Page 212: ...16 characters by combining 0 to F and X in one byte unit Example TRIGGER ENHANCED CANBUS DATA HEXA A9 TRIGger ENHanced CANBus DATA MSBLsb Function Sets the MSB and LSB bits of the CAN bus signal trig...

Page 213: ...r ENHanced CANBus IDOR ID x Function Queries all settings related to each ID of the OR condition of the CAN bus signal trigger Syntax TRIGger ENHanced CANBus IDOR ID x x 1 to 4 Example TRIGGER ENHANCE...

Page 214: ...IG TRIGger ENHanced CANBus IDOR ID x DATA CONDition Function Sets each data condition of the OR condition of the CAN bus signal trigger or queries the current setting Syntax TRIGger ENHanced CANBus ID...

Page 215: ...CANBus IDOR ID x FORMat x 1 to 4 Example TRIGGER ENHANCED CANBUS IDOR ID1 FORMAT STD TRIGGER ENHANCED CANBUS IDOR ID1 FORMAT TRIGGER ENHANCED CANBUS IDOR ID1 FORMAT STD TRIGger ENHanced CANBus IDOR I...

Page 216: ...TD PATTERN TRIGGER ENHANCED CANBUS IDOR ID1 IDSTD PATTERN 10111011111 TRIGger ENHanced CANBus IDOR ID x IDEXt Function Queries all settings related to the ID of each extended format of the OR conditio...

Page 217: ...s RTR DATA DONTcare REMote TRIGger ENHanced CANBus RTR Example TRIGGER ENHANCED CANBUS RTR DATA TRIGGER ENHANCED CANBUS RTR TRIGGER ENHANCED CANBUS RTR DATA TRIGger ENHanced CANBus IDOR ID x MODE Func...

Page 218: ...BIT10ADDRESS PATTERN 10111011111 TRIGGER ENHANCED I2CBUS ADATA BIT10ADDRESS PATTERN TRIGGER ENHANCED I2CBUS ADATA BIT10ADDRESS PATTERN 10111011111 TRIGger ENHanced CANBus SOURce Function Sets the tri...

Page 219: ...ger Syntax TRIGger ENHanced I2CBus ADATa BIT7APsub SADDress Example TRIGGER ENHANCED I2CBUS ADATA BIT7APSUB SADDRESS TRIGGER ENHANCED I2CBUS ADATA BIT7APSUB SADDRESS PATTERN 10101011 TRIGger ENHanced...

Page 220: ...CED I2CBUS DATA CONDITION TRIGGER ENHANCED I2CBUS DATA CONDITION TRUE TRIGger ENHanced I2CBus ADATa BIT7APsub SADDress HEXA Function Sets the Sub address of the 7 bit Sub address of the I2 C bus trigg...

Page 221: ...d X Example TRIGGER ENHANCED I2CBUS DATA PATTERN1 10101011 TRIGGER ENHANCED I2CBUS DATA PATTERN1 TRIGGER ENHANCED I2CBUS DATA PATTERN1 10101011 TRIGger ENHanced I2CBus DATA PMODe Function Sets the pat...

Page 222: ...r ENHanced I2CBus MODE ADATa ESTart GCALl NAIGnore SBHSmode TRIGger ENHanced I2CBus MODE Example TRIGGER ENHANCED I2CBUS MODE ADATA TRIGGER ENHANCED I2CBUS MODE TRIGGER ENHANCED I2CBUS MODE ADATA TRIG...

Page 223: ...CED LINBUS SOURCE 1 TRIGGER ENHANCED LINBUS SOURCE TRIGGER ENHANCED LINBUS SOURCE 1 TRIGger ENHanced SPATtern Serial Pattern Function Queries all settings related to the serial pattern trigger Syntax...

Page 224: ...tern CLOCk MODE ON TRIGger ENHanced SPATtern DATA Function Queries all settings related to data of the serial pattern trigger Syntax TRIGger ENHanced SPATtern DATA Example TRIGGER ENHANCED SPATTERN DA...

Page 225: ...N TRIGGER ENHANCED SPATTERN PATTERN 1100110111101111 TRIGger ENHanced SPIBus Function Queries all settings related to the SPI bus trigger Syntax TRIGger ENHanced SPIBus Example TRIGGER ENHANCED SPIBUS...

Page 226: ...data of the SPI bus trigger Syntax TRIGger ENHanced SPIBus DATA x x 1 or 2 Example TRIGGER ENHANCED SPIBUS DATA1 TRIGGER ENHANCED SPIBUS DATA1 BYTE 1 CONDITION TRUE DPOSITION 1 PATTERN1 00010010 PATTE...

Page 227: ...PIBUS MODE TRIGGER ENHANCED SPIBUS MODE WIRE3 TRIGger ENHanced TV Function Queries all settings related to the TV trigger Syntax TRIGger ENHanced TV Example TRIGGER ENHANCED TV TRIGGER ENHANCED TV CUS...

Page 228: ...fine POLarity Example The following is an example for the HDTV TRIGGER ENHANCED TV HDTV POLARITY NEGATIVE TRIGGER ENHANCED TV HDTV POLARITY TRIGGER ENHANCED TV HDTV POLARITY NEGATIVE TRIGger ENHanced...

Page 229: ...TRIGger ENHanced UART BRATe Function Sets the UART signal trigger bit rate data transfer rate or queries the current setting Syntax TRIGger ENHanced UART BRATe NRf USER NRf TRIGger ENHanced UART BRATe...

Page 230: ...T is valid when TRIGger TYPE EDGE EQUalify and TRIGger SOURce CHANnel x WINDow ON FALL RISE is valid when TRIGger TYPE EDGE EQUalify and TRIGger SOURce CHANnel x WINDow OFF ENTer EXIT is valid when TR...

Page 231: ...OUPling AC DC TRIGger SOURce CHANnel x COUPling x 1 to 4 Example TRIGGER SOURCE CHANNEL1 COUPLING AC TRIGGER SOURCE CHANNEL1 COUPLING TRIGGER SOURCE CHANNEL1 COUPLING DC TRIGger SOURce CHANnel x HFRej...

Page 232: ...OURce EXTernal Example TRIGGER SOURCE EXTERNAL TRIGGER SOURCE EXTERNAL LEVEL 0 000E 00 PROBE 1 TRIGger SOURce EXTernal LEVel Function Sets the trigger level of the external trigger or queries the curr...

Page 233: ...IGger SOURce CHANnel x WINDow ON HIGH LOW is valid when TRIGger TYPE PQUalify PULSe and TRIGger SOURce CHANnel x WINDow OFF FALSe TRUE is valid when TRIGger TYPE PSTATe TRIGger WIDTh SOURce Function S...

Page 234: ...ta specified by WAVeform TRACe to physical values Syntax WAVeform OFFSet Example WAVEFORM OFFSET 0 000E 00 Description The offset value is used when converting the Block data that is output using WAVe...

Page 235: ...m the record number specified by WAVeform RECord NRf 1 WAVeform SIGN Function Queries the existence of a sign when querying the waveform data specified by WAVeform TRACe using binary data Syntax WAVef...

Page 236: ...OOM ALLOCATION1 TRACE1 ON ZOOM ALLOCATION1 TRACE1 ZOOM ALLOCATION1 TRACE1 1 ZOOM FORMat x Function Sets the display format of the zoom waveform or queries the current setting Syntax ZOOM FORMat x DUAL...

Page 237: ...yntax ZOOM TYPE x HORizontal VERTical ZOOM TYPE x x 1 or 2 Example ZOOM TYPE1 VERTICAL ZOOM TYPE1 ZOOM TYPE1 VERTICAL ZOOM VERTical x Function Queries all settings related to the vertical zoom Syntax...

Page 238: ...r the contents of the standard event enable register For details on the standard event enable register see page 6 4 5 32 Common Command Group The commands in the common group are defined in the USBTMC...

Page 239: ...AL EVENT1 STATE CHANNEL1 DONTCARE CHANNEL2 DONTCARE CHANNEL3 DONTCARE CHANNEL4 DONTCARE LOGIC AND TRIGGER EINTERVAL EVENT1 WIDTH MODE OUT POLARITY POSITIVE SOURCE 1 TIME1 1 000E 09 TIME2 2 000E 09 TRI...

Page 240: ...ng The register is cleared when the value rounded to an integer is a non zero value Standard event enable register Extended event enable register Transition filter Syntax PSC NRf PSC NRf 0 not clear n...

Page 241: ...the self test is successful 0 is returned If there is an error 1 is returned WAI WAIt Function Holds the subsequent command until the completion of the specified overlap operation Syntax WAI Example W...

Page 242: ...7 6 5 4 3 2 1 0 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Condition register Transition filter Extended event register 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Extended...

Page 243: ...Byte Registers that affect the bits of the status byte are shown below Standard event register Sets bit 5 ESB of the status byte to 1 or 0 Output queue Sets bit 4 MAV of the status byte to 1 or 0 Ext...

Page 244: ...use SRE For details on the SRE command see chapter 5 Operation of the Status Byte A service request is issued when bit 6 of the status byte becomes 1 Bit 6 is set to 1 when any of the other bits becom...

Page 245: ...he status byte to change set the corresponding bit in the standard event enable register to 0 Refer to Chapter 4 For example to mask bit 2 QYE so that ESB will not be set to 1 even if a query error oc...

Page 246: ...or while screen image data is being saved Bit 6 ACS Accessing Set to 1 while a storage drive is being accessed Bit 7 MES Measuring Set to 1 when automated measurement of waveform parameters is in pro...

Page 247: ...cannot be emptied using the CLS command To see whether the output queue is empty or not check bit 4 MAV of the status byt D1 D2 D1 D2 D1 Error Queue The error queue stores the error No and message wh...

Page 248: ...69 6A 6B 6C 6D 6E 6F 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7D 7E 7F 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46...

Page 249: ...string Chapter 5 113 Undefined header Check the header 4 4 Chapter 5 114 Header suffix out of range Check the header 4 4 Chapter 5 120 Numeric data error A number is required in the NRf form 4 6 123 E...

Page 250: ...ATED Check transmission reception order 4 2 430 Query DEADLOCKED Limit the length of the program message including PMT to 1024 bytes or less 4 2 440 Query UNTERMINATED after indefinite response Do not...

Page 251: ...High Low LOW Low P P PTOPeak P P Hi Low HILow Hi Low Over POVershoot Over Over NOVershoot Over Rms RMS Rms Mean MEAN Mean Sdev SDEViation Sdev IntegTY TYINteg ITY C Rms CRMS CRms C Mean CMEan CMean C...

Page 252: ...Screen When Displaying Measured Results Crossing PCROssing Cross Eye Height EHEight EyeHi Eye Width EWIDth EyeWid Q Factor QFACtor QFact Jitter JITTer Jitter Duty Cycle Distriction PDUTycycle DCDTime...

Page 253: ...ut 5 100 eye pattern 5 143 eye pattern parameter name App 5 Symbol Page boolean 4 7 current 4 6 frequency 4 6 RMT 4 1 time 4 6 voltage 4 6 A Page accumulated histogram automated measurement 5 36 autom...

Page 254: ...195 horizontal zoom 5 202 I Page I2C bus trigger enhanced 5 184 I2C bus trigger event 5 162 IIR filter computation 5 115 IMAGe group 5 112 INITialize group 5 113 initial point 5 117 input coupling 5...

Page 255: ...nt register 6 4 STARt group 5 139 statistical processing history data 5 123 status byte 6 3 STATus group 5 140 status report 6 1 STOP group 5 141 string data 4 7 subtraction 5 117 SYSTem group 5 142 s...

Page 256: ...r name App 4 waveform zoom 5 202 wave search zone edit menu 5 109 window trigger width 5 198 X Page X axis trace 5 64 XY display function automated measurement 5 61 cursor measurement 5 61 gate functi...