5-9
IM 701310-17E
Commands
1
2
3
4
5
6
App
Index
Command
Function
Page
Sets the source trace of the marker cursor or queries the current setting.
Queries all settings related to the voltage measurement of the marker cursor. 5-76
Turns ON/OFF the voltage measurement of the maker cursor or queries the
Queries the voltage value at the marker cursor position.
Sets the marker cursor form or queries the current setting.
Queries all settings related to the serial cursors.
Queries all settings related to the serial cursor.
Sets the active level of the serial cursor or queries the current setting.
Sets the bit length of the serial cursor or queries the current setting.
Sets the bit rate of the serial cursor or queries the current setting.
Sets the bit order of the serial cursor or queries the current setting.
Sets the display format of the serial cursor or queries the current setting.
Sets the hysteresis of the serial cursor or queries the current setting.
:CURSor:SERial:SCURsor<x>:JUMP
Moves the serial cursor to the specified direction.
:CURSor:SERial:SCURsor<x>:LEVel
Sets the threshold level of the serial cursor or queries the current setting.
:CURSor:SERial:SCURsor<x>:MODE
Turns ON/OFF the serial cursor or queries the current setting.
Sets the serial cursor position or queries the current setting.
:CURSor:SERial:SCURsor<x>:TRACE
Sets the trace of the serial cursor or queries the current setting.
:CURSor:SERial:SCURsor<x>:TRACK
Jumps the serial cursor onto the zoom waveform.
Queries the measured value of the serial cursor.
Sets the cursor type or queries the current setting.
Queries all settings related to the vertical cursors.
Queries all settings related to basic items of the vertical cursors.
Turns ON/OFF all basic items of the vertical cursors.
Queries all settings related to the ∆T measurement of the vertical cursors.
Turns ON/OFF the ∆T measurement of the vertical cursors or queries the
Queries the ∆T value of the vertical cursors.
Turns ON/OFF the vertical cursor link or queries the current setting.
:CURSor:VERTical[:BASic]:PERDt?
Queries all settings related to the 1/∆T measurement of the vertical cursors.
:CURSor:VERTical[:BASic]:PERDt:
Turns ON/OFF the 1/∆T measurement of the vertical cursors or queries the
:CURSor:VERTical[:BASic]:PERDt:
Queries the 1/∆T value of the vertical cursors.
:CURSor:VERTical[:BASic]:T<x>?
Queries all settings related to the vertical cursor.
:CURSor:VERTical[:BASic]:T<x>:
Jumps to the center position of the zoom waveform of the vertical cursor.
:CURSor:VERTical[:BASic]:T<x>:
Sets the vertical cursor position or queries the current setting.
:CURSor:VERTical[:BASic]:T<x>:
Turns ON/OFF the vertical cursor or queries the current setting.
:CURSor:VERTical[:BASic]:T<x>:
Queries the time value at the vertical cursor.
Queries all settings related to calculation items of the vertical cursors.
Turns ON/OFF all calculation items of the vertical cursors.
Sets the equation of the calculation item of the vertical cursor or queries the
Turns ON/OFF the calculation item of the vertical cursor or queries the
Queries the measured value of the calculation item of the vertical cursor.
5.1 List of Commands