A short press on the button on the module allows you to turn the light on or off at 100%. A double press allows you to set the

lighting to the stored intensity value. The two functions can be reversed by performing 

29 

presses after unlocking the module.

Hold the button pressed (with the light on) to change brightness and store the setting. The brightness level reached is stored

when the button is released. Press again to reverse the dimming (up-down or down-up).

Press three times to set brightness to 50% and four times to set brightness to minimum level (adjustable).

Press six times for 100% brightness for 12 hours; press seven times to activate the children night light function.
This is outlined in the following table:

Preset dimmer settings

N. of presses

100% mode

Memory mode

1

100%

Memory

2

Memory

100%

3

50%

50%

4

Minimum level

Minimum level

6

100% for 12h

100% for 12h

7

Child night light mode

Child night light mode

1. Step 1

Press the pushbutton to be connected on the transmitter 5 times (*).

The transmitter LED will start flashing for 30 seconds indicating that the system is waiting for connection.

(*) A brief press must be shorter than 0.8 seconds.

2. Step 2

While the transmitter LED is blinking, briefly press the "Connect" area of the receiver (

located at the top of the case

).

Warning: the receiver must be powered.

To delete a connection: 

repeat the procedure above.

The MTV150EBRP timed dimmer also implements timer and child night light functions.

Important:

Firstly, use a 

23

press sequence to unlock the MTV150EBRP and configure it. 

NOTE: To configure with remote control in direct mode, the button must be configured in bistable on/off mode (default). 

Simply press 

21

times to lock the module and prevent any changes to settings (replay: 1 flash). 

WARNING: The MTV150EBRP  will lock automatically after one hour.

All configurations are stored in the case of blackout.

1) 100% light:

a brief press of the button increases brightness to 100% (factory setting). 

2) Recall memory:

the last brightness level stored by means of one long press can be recalled by pressing briefly twice (factory

setting).

3) 100% mode or brief press to recall memory:

In some applications it is preferable to recall the memory the first time you

press it. Press 

29

times to activate or deactivate the function. In this case, two presses are required to obtain 100% lighting.

The module is configured to 100% mode by default.

4) Timer configuration:

The time can be configured from 2 seconds to 4 hours by means of short press sequences (see

table). Press 

25

times to set the time in seconds (from 2 to 240 seconds) instead of minutes. Press 

26

times to return the setting

to minutes. The timer is off (unlimited time) by default.

5) Switch-off warning:

At the end of the set time, the module will flash briefly and extend lighting for another 60 seconds (or

10 seconds if the time is set in seconds). During this time, pressing the button again with restart the timer. The warning function

is preset by default. Press 

24

times to deactivate (and reactivate) the function. 

6) Relay mode:

The MTV150EBRP works as a simple relay instead of a dimmer in this mode. Press 

20

times to activate (or

deactivate) the mode (reply: 10 flashes). Dimmer is the default mode.

7)  Children  night  light:

7  short  presses  activate  the  children  night  light  mode.  The  light  sets  itself  to  20%  and  lighting

progressively dims in the course of an hour to leave only a night courtesy light for 12 hours.

DIRECT MODE RADIO CONNECTION

CONFIGURATION

OPERATION

Summary of Contents for MTV150EBRP

Page 1: ...n de phase automatique Protection lectronique contre les courts circuits et la surchauffe C BLAGE MTV150EBRP 5454813 Bouton poussoir hybride pour la variation d clairage 1 module Pr cautions d install...

Page 2: ...uminosit est alors disponible en faisant 2 appuis courts Faire 29 appuis courts pour activer ou d sactiver ce mode Temporisation La temporisation est d sactiv e en usine dur e illimit e Les r glages s...

Page 3: ...n MTV150EBRP puis faire 1 impulsion sur le bouton de l autre MTV150EBRP pour supprimer la liaison rester appuyer 4 secondes sur le bouton de chaque MTV150EBRP Veilleuse enfant 7 appuis courts sur le p...

Page 4: ...d fectueuses sans aucunes indemnit s pr judice subi et dommages et int r ts ne puissent tre r clam s r glage des dur es Appuis 1 Dur es 4 R ponses 2 11 2 minutes 1 flash 12 4 minutes 2 flashs 13 8 min...

Page 5: ...C Con le lampade a bassa tensione non mescolare i trasformatori ferromagnetici elettronici e toroidali NON INSTALLARE SU PRESE COMANDATE L installazione su prese comandate rischiosa perch l utente fi...

Page 6: ...pegnimento default Per impedire qualunque tipo di modifica sufficiente bloccare il modulo facendo 21 pressioni brevi risposta 1 lampeggio ATTENZIONE L MTV150EBRP si blocca automaticamente dopo un ora...

Page 7: ...brevi risposta 8 lampeggi 9 Durata 12 ore E possibile forzare una durata temporanea di 12 ore Per far ci fare 6 pressioni brevi Questa funzionalit pu rivelarsi utile nel caso di temporizzazione impos...

Page 8: ...renziata dei rifiuti elettrotecnici ed elettronici In alternativa alla gestione autonoma possibile consegnare l apparecchiatura che si desidera smaltire al rivenditore al momento dell acquisto di una...

Page 9: ...s RADIO TRANSMISSION The transmitter LED will light up only if radio transmission was successful Adding an intermediate receiver makes it possible to solve a problem of insufficient range Refer to the...

Page 10: ...istable on off mode default Simply press 21 times to lock the module and prevent any changes to settings replay 1 flash WARNING The MTV150EBRP will lock automatically after one hour All configurations...

Page 11: ...ash 7 times to confirm Press 28 times to restore the default setting reply 8 flashes 9 12 hour time Temporary operation for 12 hours can be forced Press 6 times to do this This function may be usedful...

Page 12: ...e Instead it is your responsibility to dispose of your waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment The separate c...

Page 13: ...do para control de luz 1 m dulo ALCANCE RADIO Gama POWER dentro de una casa de 100 m donde atraviese un muro portante perpendicular o una losa 250m en ausencia de obst culos Nota en ambos casos reducc...

Page 14: ...ci n es suficiente bloquear el m dulo con 21 pulsaciones breves respuesta 1 parpadeo ATENCI N El MTV150EBRP se bloquea autom ticamente despu s de una hora Todas las configuraciones se conservan en cas...

Page 15: ...adeos de confirmaci n Para restablecer el nivel m nimo con el valor de f brica realizar 28 pulsaciones breves respuesta 8 parpadeos 9 Duraci n 12 horas Es posible forzar una duraci n temporal de 12 ho...

Page 16: ...residuos dom sticos Por el contrario es responsabilidad del usuario desechar el equipo entreg ndolo a un punto de recogida designado para el reciclaje de residuos de equipos el ctricos y electr nicos...

Page 17: ...ohne Hindernisse Hinweis In beiden F llen reduziert sich die Reichweite in Gegenwart von Metallelementen und dem berqueren von Mauern oder Trennw nden FUNK BERTRAGUNG Die Led des Senders schaltet sic...

Page 18: ...rt ist Standardeinstellung Um jegliche nderungen zu unterbinden muss das Modul gesperrt werden indem 21 Mal kurz gedr ckt wird Antwort 1 Blinkzeichen ACHTUNG Das MTV150EBRP wird nach einer Stunde auto...

Page 19: ...e Mindestniveau wieder herzustellen 28 Mal kurz dr cken Antwort 8 Blinkzeichen 9 12 Stunden Dauer Es ist m glich eine vor bergehende Dauer von 12 Stunden herbeizuf hren Hierzu 6 Mal kurz dr cken Diese...

Page 20: ...cht zusammen mit dem Hausm ll entsorgt werden darf Es liegt daher in Ihrer Verantwortung Ihre Altger te zu entsorgen indem Sie diese bei einer geeigneten Sammelstelle f r das Recycling f r Elektro und...

Page 21: ...waarbij het signaal loodrecht door een draagmuur of een vloer moet gaan 250m in een open ruimte Opmerking in beide gevallen ver mindert het zendbereik in aanwezi gheid van metalen elementen muren of...

Page 22: ...e maken vergrendelt u de module met 21 keer snel de knop indrukken signaal knippert 1 keer OPGELET De MTV150EBRP vergrendelt zichzelf automatisch na een uur Elke configuratie blijft opgeslagen als de...

Page 23: ...vervolgens 27 keer snel in te drukken De module bevestigt met 7 knippersignalen Om de default minimum sterkte in te stellen drukt u 28 keer snel op de knop signaal knippert 8 keer 9 Tijd 12 uur U kun...

Page 24: ...duct niet samen met ander stedelijk afval mag worden verwijderd Het is uw taak om het afval van dit materiaal naar een erkend afvalinzamelpunt te brengen voor het recyclen van afgedankte elektrische e...

Page 25: ...krydsning af v gge eller skillev gge RADIO TRANSMISSION Senderens og modtagerens LED lyser kun hvis radiotransmissio nen er vellykket Tilf jelse af en ekstra modtager kan g r det muligt at l se et pro...

Page 26: ...ilstand t nding slukning default Tryk korte 21 gange for at l se modul og udg ndringer i konfiguration repons 1 blink VIGTIGT MTV150EBRP vil automatisk l se konfigurationen efter en time Alle konfigur...

Page 27: ...mumslysstyrke nskes trykkes 28 korte tryk repons 8 blink 9 12 hour time Det er muligt at forcere en midlertidig varighed p 12 timer Tryk kort 6 gange for at g re dette Denne funktion kan v re nyttig h...

Page 28: ...det til et udpeget indsamlingssted til genbrug af affald af elektrisk og elektronisk udstyr Separat indsamling og genanvendelse af dit affald p bortskaffelsestidspunktet vil bidrage til at bevare nat...

Reviews: