YMGI WMMS-09EW-V2B(59)2 Installer'S Instruction & User'S Manual Download Page 5

BRIEF UNIT INFO

IMPORTANT NOTES

These precautions are essential and must be strictly observed.

DO NOT

 pull on the power cord or refrigeration lines. 

Install them in a secured position. A line set PVC
cover is recommended.

DO NOT

 install the unit in places where there is 

exposure to flammable materials or gas. 

DO NOT

 use wire or circuit breakers that do not meet 

electrical safety standards.  Several circuits shall 
be connected to one breaker.

DO NOT

 install unit in a damp laundry room or near 

flammable gas. All units must be protected by 
certified electrical circuit breakers in accordance 
with all safety codes.

DO NOT

 use the unit in cool or dry mode for 

prolonged periods where humidity is higher than 90%. 

SAFETY WARNINGS

READ THESE SAFETY WARNINGS COMPLETELY PRIOR TO ANY USE 

DO NOT

 install the indoor unit close to cooking 

surfaces or ventilation systems. Poor placement 
could decrease efficiency and waste energy.       

DO NOT

 apply chemical solvents, flammable 

insecticides, or abrasive materials on unit. Clean the 
unit only with a soft dry cloth.

DO NOT

 continue to operate the unit if there is any 

abnormal odor, burning, scorching, or smoke. Stop 
unit operation and disconnect electrical power to the 
unit immediately, and call your technician.

DO NOT

 use the system for anything other than what 

it was designed for or any non-HVAC purposes. Do 
not store or install them near food, paint, or other 
chemicals.

DO NOT

 operate the unit for prolonged periods 

without refreshing ambient air. Open the door or 
window periodically to bring in fresh air if possible.

DO NOT

 draw on the power cord or refrigeration

lines. Install them in secured positions. PVC line set 
cover is recommended to protect against rain and 
sunlight and other potential damage.

DO NOT

 blow the cold air directly towards people

for prolonged period. Otherwise, people may get
cold.

DO NOT

 undersize wires. Do not connect several 

circuits to one breaker. Don't undersize or oversize
circuit breaker, otherwise power failure or fire may be 
caused.                

DO NOT

 wire or open unit while unit is running. 

Make sure to shut off all circuits prior to inspecting or 
servicing the unit.

 

Sparks or fire may occur. It may 

cause a shock to people. 

Ground connection

Forbidden

Disconnect the plug

Imperative

P8 OF 46

YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World !

W

ARRANTY

 POLICIES 

AND REGISTRA

TION 

CARD/FORM

WARRANTY AND TECHNICAL SUPPORT

YMGI warrants to the purchaser/owner(s) that YMGI products be free from defects in 
workmanship under the normal use and maintenance, with the standard Limited Product Warranty 
Policies that comes with the unit or sales package.

material and 

YMGI IS NOT RESPONSIBLE FOR

CONTACT FOR FIELD SERVICE OR REPAIR

The following people, in a prioritized sequence, will take care of your request or issue:
1) The original installer; otherwise,
2) Your current service contractor; otherwise,
3) Authorized contractor in YMGI list that is close to you; otherwise,
4) Authorized Distributor in YMGI Distributor list; otherwise,
5) Contractor/Distributor you prefer who is close to you.

CONTACT FOR GENERAL TECHNICAL QUESTIONS OR SUPPORT, IN A SEQUENCE:

1) The original installer; otherwise,
2) The current service contractor; otherwise,

3) The distributor; where the unit is purchased from otherwise,
4) YMGI Technical Support:
    Tel: (866) 833-3138*703          Email: [email protected]

* Regular equipment maintenance or field service or field inspection.

* Damage or repairs required as a consequence Customer do-it-yoursely(DIY) installation and/or any other faulty 
   installation or improper application.

* Failure to start due to voltage conditions, blown fuses, open circuit breakers, or other damages due to the 
  inadequacy or interruption of electrical service.

* Damage or repairs needed as a consequence of any misapplication, abuse, improper servicing, unauthorized 
  alteration, or improper operation.
* Damage as a result of floods, winds, fires, lightening, accidents, corrosive atmosphere, or other conditions 
  beyond the control of YMGI.

* Parts not supplied or designated by YMGI.
* Products installed outside USA or Canada.

* Any damages to person or property of whatever kind, direct or indirect, special or consequential, whether 
  resulting from use or loss of use of the product.

The original licensed installer or current service contractor should be contacted first of all, since they installed 
the unit and/or know more details than anybody else.
They will check the unit and find out the problems with the professional knowledge about HVAC and electric 
product installation by using special tools or instrument.
They can contact YMGI technical support for technical help during unit installation or inspection.
Product model and serial numbers needed, which can be found on unit nameplate sticker, so that our 
technician can quickly identify the unit, parts and wiring diagrams, among our many products and models.

* Any problems due to improper cooling and heating load calcuation of the room/building the air conditioner/heat 
  pump system is to be installed. Equipment users can get the calculation schedule from your room/building 
  architect or your installation or related service HVAC contractor, who should have the knowledge and the tools 
  to do these calculations correctly.
* Any problems due to improper sizing and selecting air conditioner/heat pump system. These equipment sizing 
  and selection work should be conducted by either your room/building architect or your installation or related 
  service HVAC contractor, who should have the knowledge and the tools to do these calculations correctly, and 
  get your approval, before purchasing the air conditioner or heat pump equipment.
* Any problems due to improper installing of the air conditioner/heat pump system. Installation should be 
  conducted by currently licensed HVAC technician, following manufacturer installation instructions, all governing 
  safety codes, with care and professionalism. 
* Any problems due to improper operation of the air conditioner/heat pump system. Users shall keep the manual 
  and refer to it for the correct understanding of how the unit will work and how to operate the unit correctly.
* Any problems due to improper maintenance of the air conditioner/heat pump system. Like a car, regular 
  maintenance or yearly checking is necessary for the unit to work properly for you, before the season comes. For 
  example, air filter shall be checked for cleaness from time to time. Remote control batteries shall be checked for 
  enough power, before judging the unit is not working...

P7 OF 46

YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World !

Summary of Contents for WMMS-09EW-V2B(59)2

Page 1: ...r Local Codes and related manuals from YMGI Otherwise damage to equipment or property even injury to people may occur Installer Currently licensed HVAC technician only Read manual before installation...

Page 2: ...d for an extended period of time The information we provide in our manuals is for the sole purpose of reminding you and your installer It is our ultimate goal to help insure that your YMGI units are i...

Page 3: ...e humidity ranges installation operation maintenance service warranty parts and so on 4 Properly select correct most suitable YMGI product models of units and accessories for your HVAC applications jo...

Page 4: ...he installation 5 Supply electrical power V Ph Hz measured at wiring terminal block of Indoor unit outdoor unit 7 Wire gauge length and terminal colors between circuit breaker disconnect switch to out...

Page 5: ...rvice contractor otherwise 3 The distributor where the unit is purchased from otherwise 4 YMGI Technical Support Tel 866 833 3138 703 Email techsp ymgigroup com Regular equipment maintenance or field...

Page 6: ...0 0 2 1 Cross Flow 1 3 6 x25 4 MP24AA 2 2 4 NA Blue Yes 1 4 3 8 0 67 NA Yes Standard Washable 2 Yes Yes Yes Yes 32 7 x 11 2 x 7 9 35 7 x 15 2 x 10 7 24 3 30 8 240 480 540 208 230 1 60 187 253V 12000 9...

Page 7: ...PE OUT TEM SENSOR ROOM TEM SENSOR FAN MOTOR M1 RT4 RT3 RT2 RT1 4 3 2 TUBE 1 TUBE TUBE 0 ROOM PG PGF CAP JUMP AP2 DISP1 DISP2 SWING UD TR OUT1 TR IN M2 N1 COMU AC L BU BK BN XT N 1 2 3 YEGN E INDOOR UN...

Page 8: ...Tool Set Not Shown Hex Head Key Set Torch for AC Application Not Shown Heat Absorbtion Flux Nitrogen Not Shown Soap Bubble Not Shown Vacuum Pump Helium Leakage Check Not Shown Manifold Wire Cutter Wir...

Page 9: ...door unit B Indoor unit C OVER 20 OVER 10 OVER 10 OVER 8 OVER 10 OVER 2 OVER 4 OVER 4 OVER 80 INSTALLER S INSTRUCTION P16 OF 46 YMGI Engineered Comfort Products for A Sustainable and Efficient Green W...

Page 10: ...uctions of all units thoroughly Ask rep distributor us anything you are not sure about Get your tools and parts ready for installation CAUTION SUGGESTIONS TO FOLLOW PRIOR TO INSTALLATION PIPING AND WI...

Page 11: ...plate holes with those holes drilled on the wall and put anchors or screws into the holes to secure mounting plate Steps To Mount Plate a b c Drill mounting holes to make sure at least either one of t...

Page 12: ...For distance other than 25 between indoor and horizontal venting condensing units refer to the following table for copper sizes Make sure the pipe section where is to be cut is straight and smooth App...

Page 13: ...t mode you would like the unit to run in When the remote is first turned on the mode displayed will be the AUTO mode The temperature cannot be adjusted in this mode and will not display on the indoor...

Page 14: ...emote press the TIMER ON button once more and the word ON will stop blinking and stay on the remote The time you would like the unit to turn on is now set TIMER OFF BUTTON This allows you to set the t...

Page 15: ...he same time COOLING Running symbol and cooling symbol are lit HEATING Running lamp and heating symbol are lit DRY Running lamp and dry lamp are lit FAN Running lamp and fan lamp are lit AUTO Auto lam...

Page 16: ...or discoloration to Install front panel Place two supporters of the front panel into the slots along the direction of arrows to cover and clasp the front panel As show in right figure If at any time t...

Page 17: ...orized service center for professional repair Following checks prior to contact may save your time and costs Phenomenon Normal or Abnormal The unit doesn t deliver cooling or heating immediately after...

Page 18: ...leaking 3 Is condensate drain hose clogged or restricted 4 Is condensate drain hose insulated 5 Is the 3 hole at exterior wall staffed or sealed Noise is heard at indoor unit 1 Is the fan motor or co...

Page 19: ...32 Transformer 48X26P 1 33 Wire clamp 1 34 Rear clamp 1 35 Connecting cable 1 36 swing louver clamp 1 37 swing louver 1 38 swing louver up 1 39 swing louver down No Description Tube sensor 20K Part C...

Page 20: ...1 Front panel 200022921 1 Guide louver 261120432 1 Guide louver 261120422 1 Motor MP28EC 15212002 1 Right motor clamp 26112429 1 Bearing holder 26152423 1 Motor FN20M PG 150120873 1 Electric box cove...

Page 21: ...experience to correct the problem more efficiently A technician s may be unwilling to repair an issue on a unit that they did not install If you do find a technician willing to perform the service the...

Page 22: ...ereafter in this and other documents that we publish 2 You will follow what is written hereafter in this and other documents that we publish 3 You will be bound by and completely follow all policies g...

Page 23: ...s available based on the actual need at YMGI s determination This option shall be the last resort due to refrigerant and wiring considerations All unit removal re installation and shipping cost are th...

Page 24: ...Read and follow all policies set forth from the distributor from which you purchased your unit Upon purchase and installation of the unit s you agree to be bounded by all policies published by both di...

Reviews: