27
High system pressure
protection
Pressure switch failure
Pressure detection switch on the
control panel failure
Measured system pressure exceeds
system limit
33
○
X
X
★
Indoor unit temperature
sensor failure
Indoor unit temperature sensor is
loose
Indoor unit temperature sensor
failure
34
○
X
★
X
Indoor unit coil
temperature sensor failure
Indoor coil temperature sensor is
loose
Indoor coil temperature sensor
failure
Indoor control board failure
36
○
★
X
★
Communication failure
between Indoor unit and
Outdoor unit
Communication cable is loose
Communication cable has failed
Connection between filter board and
Outdoor unit control board is
incorrect or loose
Connection between filter board and
terminal is incorrect or loose
38
○
★
★
★
Indoor EEPROM failure
EEPROM chip is loose
Indoor control board failure
39
○
X
★
★
Indoor fan motor running
abnormally
Fan motor is blocked
Fan motor cord connection is loose
Fan motor failure
Indoor control board failure
41
★
★
○
★
Indoor grounding
protection failure
Indoor control board failure