![YMGI WMMS-09C-V2B(78)1 Installer'S Instruction & User'S Manual Download Page 42](http://html1.mh-extra.com/html/ymgi/wmms-09c-v2b-78-1/wmms-09c-v2b-78-1_installers-instruction-and-users-manual_910615042.webp)
YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World!
42
Error and Protection Codes
Indication on the outdoor unit
When the unit has an issue, or the compressor stops running, the LEDs on the outdoor control board will show the error
sequence automatically.
Key:
★ : LIGHT
○ : FLASHING LIGHT
X : OFF
Outdoor Unit
Failure Description
LED 1 LED 2 LED 3 Possible Cause
Lights will flash every second for the following faults
Normal Operation
x
x
x
Outdoor coil temperature
sensor issue
★
X
★
Outdoor coil sensor connection is loose
Outdoor coil temperature sensor has failed
Outdoor control board has failed
Compressor exhaust
temperature sensor issue
★
X
X
Compressor exhaust temperature sensor connection is loose
Compressor exhaust temperature sensor has failed
Outdoor control board has failed
Communication failure
between Indoor Unit and
Outdoor Unit
X
X
○
Communication cable connection is loose
Communication cable has failed
Connection between the filter board and the outdoor control
board is incorrect or loose
Connection between the filter board and the terminal is incorrect
or loose
Indoor unit control board failure
PFC board failure
Power board failure
Outdoor control board failure
Current Overload
Protection
★
○
X
Fan motor is running abnormally
Condenser and evaporator are dirty
Air inlet and outlet are abnormal
Maximum Current
Protection
★
○
★
Outdoor control board has a short circuit
Drive board has a short circuit
Other component has a short circuit
Communication issue
between Outdoor Unit
and Driver
X
★
★
Connection wires connection loose
Outdoor board or drive board failure
Outdoor EEPROM issue
★
★
★
EEPROM chip is loose
EEPROM chip is inserted backwards
EEPROM chip has failed
Compressor exhaust
temperature is too high
protection
X
○
★
Compressor exhaust temperature sensor failure
Unit does not have enough refrigerant
Outdoor ambient
temperature sensor issue
★
★
X
Outdoor ambient temperature sensor connection is loose
Outdoor ambient temperature sensor failure
Outdoor control board failure