background image

EN

11

obligatory to install an electric fuse 10 А for water heater electric 
capacity up to 2 kW and 16 A for electric capacity of 3 kW. The 
electric installation to which the heater will be connected must be 
built in accordance with the requirements of the applicable statutes 
and local regulations in force. Where the regulations in force do not 
require that in the water heater circuit be installed an automatic 
breaker  against  leakage  of  current  (residual  current  protection 
device), we recommend to install such a device. 
The connection of the cables from the mains switchboard to the 
unit  terminals  shall  be  carried  out  after  carefully  removing  the 
plastic  cover  so  that  the  electrical  wiring  in  the  unit  does  not 
disengage. In accordance with electric circuit schema glued on the 
cover  connect  the  phase  conductor  of  the  power  wire  to  the 
terminal marked L (or A1 depending on the version), the neutral 
wire to the terminal marked N (or B1) and the earthling - to the 
security terminal (screw or stud) marked for safety grounding. The 
power cord must be secured against displacement by using the 
cable clamp located next to the cable entry in the plastic cover. 
After connecting and attaching the power cable, put the plastic 
cover into place and secure it with screws, taking care for free 
movement  of  cables,  thermostat  capillary  tube  and  the  control 
switch.
If you have purchased water heater with pre-installed power cord 
with a plug, the electric connection shall be carried out as the plug in 
put directly in a functioning and grounded socket of the premise 
electric installation. The socket should be on a separate, dedicated 
only  for  the  water  heater  circuit  and  located  so  as  to  be  easily 
accessible  after  the  unit  installation.  The  section  of  the  electric 
installation wires in which the socket is placed must be suitable for 
the water heater electric power consumption. On the phase line 
must be installed a fuse (10 A for a capacity of 2 kW and 16 A for 3 
kW). The installation must be carried out in compliance with the 
regulations in force. Taking out the power cord plug from its socket 
shuts down the water heater. Faulty and / or inappropriate electric 
installation and / or socket are high-risk conditions for accidents 
with  damages  to  the  product  and  possible  damages  to  the 
environment, objects and living species.
Once the appliance is connected to the power supply grid check its 
functionality.

WARNING! Failure to comply with the requirements concerning 
connection to the mains shall impede the appliance safety, in 
which it is prohibited to use. Adverse effects occurring as a result 
of non-compliance with requirements concerning the appliance 
electric  connection  are  not  covered  by  the  manufacturer  and 
seller  warranty  liabilities  and  are  at  the  expense  of  the  party 
violating the requirements of this instruction manual.

The water heater connection to the power supply and checks of its 
functionality shall be performed only by specialists and are not 
manufacturer or seller obligations and are not subject to warranty 
service.

HOW TO USE THE APPLIANCE

The water heater is switched on operative mode by switching the 
light key by pressing its extremity marked „І”. With the knob you 
may adjust to desired water temperature. Lighting of the key when 
in switched on position indicates that the water heater is operating 
and water is heating, while when the light is off it indicates that the 
water  has  reached  adjusted  temperature  and  the  heater  is 
switched off. You may switch off the appliance by pressing the end 
of  the  button  of  the  glowing  key  marked  "0". The  water  heater 

complete disconnection from power supply takes place from the 
additional disconnecting device.
For models marked with the letter "D" each key on the two-buttons 
light key located on the control dashboard serves to switch on / off 
one of the heaters. Thus you may use appliance half or full electric 
power depending on the specific needs and desired time for water 
heating.
The chart around the thermostat knob has a distinct sector marked 
ECO. When the cursor of the knob is in the sector, the water 
is warmed to an optimum temperature at which the heat losses of 
the device are reduced and the reduced use of electric energy. 
At the same time, the warm water is sufficient for normal 
households. When a need for a large amount of mixed water is 
required the thermostat  knob  is  rotated  in  the  direction  of 
travel counterclockwise  to  its  maximum  position,  to  reach  the 
higher temperature of the water in the tank. We recommend to 
keep the knob in the sector ECO, when the heater is left on for 
long periods without use of hot water and only to store heated 
water. 
The  appliance  built-in  thermostat  unit  has  antifreeze  function. 
When  the  thermostat  knob  is  to  the  extreme  left,  at  the  scale 
beginning,  the  heater  shall  switch  on  at  ambient  temperature 
around 8-10°C and shall switch off at about 12-15°C. Thus in 
case of air temperature fall in the room, the water in the tank 
will be protected  from  freezing.  ATTENTION!  This  feature 
shall  not prevent the water in the room plumbing from freezing!
Switching on and off, set up and using water heaters equipped 
with electronic  control  board  takes  place  in  accordance 
with  the instructions  and  requirements  listed  in  the 
additional  manual supplied with the appliance - instruction how to 
connect and use an appliance with electronic control board. For 
such appliances the additional  instruction  manual  is  an 
integral  part  of  the  present installation and operation manual.
The  temperature indicator  installed  on  the  appliance  external 
coating indicates the process of water heating. It is not a device for 
control  measurement  and  indicates  only  the  approximate 
temperature and quantity of hot water within the water tank.

WARNING! Do never switch the appliance if there is a chance 
that the water in the water tank is frozen! This shall damage 
both heater and the tank.
WARNING! This appliance may be used by children of age 
over  eight  years  old  and  persons  with  reduced  physical, 
sensory  or  mental  capabilities,  or  lack  of  experience  and 
knowledge, where they are under supervision or instructed 
about  the  safe  use  of  the  appliance  and  understand  the 
dangers. Children must not be allowed to play with the unit! It 
is absolutely forbidden that children undertake cleaning or 
servicing of this appliance!

Within the combined valve is built a special valve which during 
water heater normal operation allows the expanded during heating 
water not to leak through the valve side hole, but to pass into cold 
water plumbing. The quantity of this water is negligible and usually 
is  with  low  temperature.  During  normal  operation  of  the  water 
heater, as well as in present of additional return valve, it is possible 
that through the valve side opening leak some water drops. This 

Summary of Contents for 30

Page 1: ...EN HOUSEHOLD ELECTRIC WATER HEATERS 30 120 designed for wall installation MANUAL FOR INSTALLATION OPERATION AND MAINTENANCE...

Page 2: ...D 1 2 3 4 5 6 7 8 EN RO LED RU NL DE FR 1 2 3 4 5 6 7 8 Wasseranschluss Ablauf Wasser Kombiniertes Ventil Schalter Thermostat Anodentester Elektronischen Steuereinheit LED Entr e de l eau Sortie de l...

Page 3: ...175 D 387 387 387 462 435 462 435 462 435 E 80 80 80 96 85 96 85 96 85 F 410 410 410 484 455 484 455 484 455 50 80 80 100 120 Fig 2 2 3 2 760 1125 835 1005 1170 C 155 155 185 185 185 D 387 387 462 46...

Page 4: ...Ablauf Wasser W rmetauscher I W rmetauscher II Thermostatmuffe Entr e de l eau Sortie de l eau changeur de chaleur I changeur de chaleur II Douille de thermostat Inlaat water Uitlaat water Warmtewiss...

Page 5: ...250 250 250 250 J 450 450 450 450 450 450 630 K 770 780 365 355 L 220 200 80 80 100 120 Fig 7 0 36 0 35 0 35 0 59 D 387 462 462 462 E 80 96 96 96 M 770 415 587 753 C 155 185 185 185 K 223 250 250 250...

Page 6: ...r Signal lamp LED 1 2 3 4 5 6 7 Interrupteur thermique Thermostat Bouton Thermostat Anode Testeur anode LED Temperatuurbegrenzer Thermostaat Schakelaar Verwarmingsunit Anode Anode tester LED Termo ntr...

Page 7: ...vented certified While the units themselves can often be simple to install to comply with UK laws all installers must be unvented certified If you are unsure on how to fit the unit please contact YGHP...

Page 8: ...dandcompetentpersonsinaccordancewiththeirdesign Thewayofuse of such water heater when heating the water in its tank from an alternative electric coolant as well as compliance with safety measures must...

Page 9: ...pipes for cold and hot water of some vertical and horizontal water heaters arelocatedontherightsideofthewall mountedunit B the outlets of cold hot water pipes of horizontal water heatersarelocatedbelo...

Page 10: ...s are shown the distances between the bolts studs for mountingtheunits WARNING The bearing plates of horizontal water heaters must be securely clamped to the premise wall Under the bolts heads nutsons...

Page 11: ...while the water tank is partially or completely emptied of water Do not forget to fill the tank with water before putting it backintooperation WARNING Thecoolantcirculationthroughtheheatexchanger of...

Page 12: ...tes that the water heater is operating and water is heating while when the light is off it indicates that the water has reached adjusted temperature and the heater is switched off You may switch off t...

Page 13: ...ficiency criterion is its arrow deflection When at the time of pressing the tester button the arrow does not divert or is hold at the beginning of the red section you should contact the specialists at...

Page 14: ...hall be in force the applicable laws regulations and other legislation dealing with the rights and obligations of consumer seller and manufacturer and their relationships related to purchased water he...

Reviews: