should not be perceived as defect and the side hole of combined 
valve should not be blocked because it shall cause destruction of 
the  tank.  The  built-in  non-return  valve  in  the  combined  valve 
prevents, in case of cutting water supply, the water in the water 
tank to return to cold water pipeline.
Using  the  built-in  heater  exchangers  (for  appliances  equipped 
with) to heat the water in the tank must take place in accordance 
with the instruction provided for by the persons who carried out the 
design  and  installation  of  the  system  for  heating  water  from 
alternative  electric  sources.  Compliance  with  the  instruction  in 
such guides is mandatory.
When the appliance is used in areas with water rich in limestone it 
is possible to hear some noises during water heating. The noise is 
due to the limestone deposition on the heater and in the tank. The 
quantity of limestone contained depends of the type of water and 
its heating temperature. When the latter is higher than 60°С the 
quantity of separate limestone increases. Accumulated limestone 
impedes the heater efficiency and may even cause its failure, while 
increasing the time for water heating.
When using the appliance it is possible to hear some weak noise 
due to the water flow through the pipelines and the appliance, as 
well as to the natural process of expanding and heating.
When  the  heater  is  regularly  used  to  heat  water  to  a  lower 
temperature,  it  is  recommended  to  turn  the  thermostat  knob  at 
least once monthly to its maximum position, then to heat the water 
to maximum degrees and keep it such at least for 24 hours. The 
purpose it to prevent bacteria growth.

ADDITIONAL CORROSION PROTECTION

Enameled  water  heater  tanks.  In  each  water  heater  with 
enameled  tank  is  installed  additional  corrosion  protection.  It 
consists of an anode of special alloy operating only when the water 
tank is full. The anode is a consumable (i.e. a device with normal 
wear during the appliance operation) and its average operational 
life is up to 3 (three) years. This period depends much of the type of 
operating  the  appliance  and  the  characteristics  of  the  heated 
water.  After  the  period  of  operational  life,  a  manufacturer 
authorized specialist or dealer service company must check the 
conditions of the anode. Where necessary it should be replaced 
with new one. Compliance with the inspection deadline and timely 
replacement of the anode is important for the effective protection 
of the tank from corrosion. Both the assessment and replacement 
of the anode are not subject of manufacturer and seller warranty 
liabilities.
Water  heater  with  enamel  tank  and  anode  tester.  The 
availability of the anode tester as control device is essential for the 
heater operation. Some water heater modifications with traditional 
thermostat  are  equipped  with  electromechanical  anode  tester 
(Fig. 9). It consists of a arrow-indicating system with a scale and 
switch (button). The scale has two sections - red and green. In tank 
normal operating condition the tester pointer is in the red section - 
the tester is not switched on and the anode is working properly. 
Checking the anode efficiency is carried out when the water is fully 
heated (switched off  thermostat, i.e. the key is not lit) by pressing 
for few seconds the button on the tester. The arrow shall depart in 
the  direction  of  the  scale  green  sector.  The  magnitude  of  the 
variation is strongly affected by the parameters of the water and its 
temperature,  as  the  boundary  between  the  two  sectors 
correspond  to  the  water  average  values.  The  anode  efficiency 
criterion is its arrow deflection. When at the time of pressing the 

tester button, the arrow does not divert or is hold at the beginning 
of  the  red  section,  you  should  contact  the  specialists  at  your 
nearest  manufacturer  or  vendor  authorized  service  company. 
Their  specialist  shall  review  the  tank  corrosion  protection  and 
repair,  if  necessary.  In  some  water  heaters  modifications  the 
electronic control board indicates the anode efficiency and degree 
of wear with periodic regular display blinking. With advanced wear 
the size of lighted part decreases. More specifically the process is 
described  in  the  additional  instruction  manual  concerning  the 
electronic  control  board  functions.  Once  the  lighted  part  of  the 
display  switches  off  completely  you  may  contact  the  closest 
service company to review and eventually replace the anode.
Water  tanks  of  high  quality  chrome-nickel  steel.  Corrosion 
protection and guaranteed long life are secured by correct choice of 
steel, adequate design and engineering construction during tank 
manufacture process.

SERVICE, PREVENTION, MAINTENANCE

In order to secure reliable operation of the water tank in areas with 
highly calcareous water it is recommended to clean the limestone 
accumulated within. This operation should take place at least once 
every two years, while in areas with higher limestone content even 
more frequently. The depositions on the enamel coating should not 
be removed otherwise than wiped with dry cotton cloth and without 
using  hard  tools.  Regular  limestone  removal  and  cleaning  is 
particularly  important  for  appliance  reliable  operation.  It  is 
recommended that during this maintenance operation you carry out 
a review of the enameled tank anode condition. These services are 
not subject to warranty coverage and must be performed only by 
qualified person.

WARNING! In order to ensure safe and trouble-free operation of 
the  water  heater,  the  combined  valve  should  be  checked 
regularly for reduction of its permeability. This is done by lifting 
the lever, and wait for 30-60 seconds from the side opening the 
valve to flow thick and strong jet of water. This operation must be 
carried out after connecting the heater to the plumbing and when 
filling of the tank with water, in the process of using the heater not 
less than once every two weeks, as well as eventually after stop 
and start of water supply. When at full tank by opening the valve 
does  not  leak  or  water  flow  is  weak,  there  is  a  failure  and 
probably the valve is clogged by impurities in the sewage. Using 
water  heater  combined  with  a  defective  valve  is  strictly 
prohibited. Switch off immediately the appliance from the power 
supply  and  contact  the  nearest  authorized  by  manufacturer 
service company. Otherwise, it will cause damage to the water 
tank, and could cause tangible and intangible damages in the 
room where the water heater is located.

When you are not certain about the temperature in the room where 
the water heater is installed, i.e. that it may fall below 0°C, the 
water  from  the  water  tank  MUST  be  drained  -  please  refer  to 
section 'CONNECTION TO THE WATER SUPPLY NETWORK'
The water heater outer shell and plastic parts can be cleaned using 
only a slightly damp soft cotton cloth and never with invasive and/or 
abrasive  substances  and  preparations.  Before  cleaning  the 
appliance, it MUST be disconnected from the power supply with the 
additional disconnection device or by unplugging the plug on the 
power cord. IT IS FORBIDDEN to clean the appliance with steam 
generator. Particular attention should be paid to prevent wetting of 
the appliance light switch on its control panel. The water heater may 
be  switched  on  in  operation  only  after  complete  removal  of 

Summary of Contents for 30

Page 1: ...EN HOUSEHOLD ELECTRIC WATER HEATERS 30 120 designed for wall installation MANUAL FOR INSTALLATION OPERATION AND MAINTENANCE...

Page 2: ...D 1 2 3 4 5 6 7 8 EN RO LED RU NL DE FR 1 2 3 4 5 6 7 8 Wasseranschluss Ablauf Wasser Kombiniertes Ventil Schalter Thermostat Anodentester Elektronischen Steuereinheit LED Entr e de l eau Sortie de l...

Page 3: ...175 D 387 387 387 462 435 462 435 462 435 E 80 80 80 96 85 96 85 96 85 F 410 410 410 484 455 484 455 484 455 50 80 80 100 120 Fig 2 2 3 2 760 1125 835 1005 1170 C 155 155 185 185 185 D 387 387 462 46...

Page 4: ...Ablauf Wasser W rmetauscher I W rmetauscher II Thermostatmuffe Entr e de l eau Sortie de l eau changeur de chaleur I changeur de chaleur II Douille de thermostat Inlaat water Uitlaat water Warmtewiss...

Page 5: ...250 250 250 250 J 450 450 450 450 450 450 630 K 770 780 365 355 L 220 200 80 80 100 120 Fig 7 0 36 0 35 0 35 0 59 D 387 462 462 462 E 80 96 96 96 M 770 415 587 753 C 155 185 185 185 K 223 250 250 250...

Page 6: ...r Signal lamp LED 1 2 3 4 5 6 7 Interrupteur thermique Thermostat Bouton Thermostat Anode Testeur anode LED Temperatuurbegrenzer Thermostaat Schakelaar Verwarmingsunit Anode Anode tester LED Termo ntr...

Page 7: ...vented certified While the units themselves can often be simple to install to comply with UK laws all installers must be unvented certified If you are unsure on how to fit the unit please contact YGHP...

Page 8: ...dandcompetentpersonsinaccordancewiththeirdesign Thewayofuse of such water heater when heating the water in its tank from an alternative electric coolant as well as compliance with safety measures must...

Page 9: ...pipes for cold and hot water of some vertical and horizontal water heaters arelocatedontherightsideofthewall mountedunit B the outlets of cold hot water pipes of horizontal water heatersarelocatedbelo...

Page 10: ...s are shown the distances between the bolts studs for mountingtheunits WARNING The bearing plates of horizontal water heaters must be securely clamped to the premise wall Under the bolts heads nutsons...

Page 11: ...while the water tank is partially or completely emptied of water Do not forget to fill the tank with water before putting it backintooperation WARNING Thecoolantcirculationthroughtheheatexchanger of...

Page 12: ...tes that the water heater is operating and water is heating while when the light is off it indicates that the water has reached adjusted temperature and the heater is switched off You may switch off t...

Page 13: ...ficiency criterion is its arrow deflection When at the time of pressing the tester button the arrow does not divert or is hold at the beginning of the red section you should contact the specialists at...

Page 14: ...hall be in force the applicable laws regulations and other legislation dealing with the rights and obligations of consumer seller and manufacturer and their relationships related to purchased water he...

Reviews: