moisture.
The  rules  for  checking  the  corrosion  protection  and  anode 
replacement (please refer to previous section), as well as removal 
of the accumulated limestone, must be strictly observed both during 
and after the appliance warranty period.
During the appliance usage and maintenance do not damage the 
metal plate with its technical data and serial number. Should you 
take it off, keep it with the warranty form because it is the document 
serving to identify the water heater.

FAILURES

When the heater does not heat the water, check if the external 
disconnecting  device  is  not  switched  off,  if  the  lighting  key  is 
switched off and if the thermostat knob is not turned to the lowest 
position. 
If the power supply is in order, the lighting key is switched on and 
the thermostat knob is turned to its highest position, but the water 
in the appliance is still not warming (it is possible that the lighting 
key  or  the  signal  lamp  are  lighted  or  not),  using  the  external 
disconnecting device unplug the heater and contact the nearest 
authorized service company.
In case when from the mixer at completely open tap for hot water 
there is no leakage or water flow is weak, check if the filter at the 
mixer outlet is not clogged, or whether the shut-off valve before the 
heater is not fully or partially closed (4, Fig. 8), or if water supply is 
not stopped. If all listed above causes are not the cause of failure, 
using  the  external  disconnecting  device  unplug  the  heater  and 
contact the nearest authorized service company.
When the water heater is equipped with electronic control board, at 
the end of the additional instruction manual are listed the error 
messages appearing on the display in case of failure and what 
measures  to  take  for  each  case.  In  any  other  general  case  of 
failure, using the external disconnecting device unplug the heater 
and contact the nearest authorized service company.
In case of failure of the power cord and/or plug for water heaters 
with  such,  contact  the  nearest  authorized  by  the  manufacturer 
service company as the cord with plug must be replaced by the 
manufacturer,  its  service  agent,  or  a  person  with  similar 
qualifications in order to avoid danger.

WARRANTY, WARRANTY PERIOD AND 
WARRANTY CONDITIONS

The  warranty,  warranty  conditions,  warranty  period,  warranty 
validity for purchased appliance and service related manufacturer 
or vendor liabilities during the appliance warranty period are listed 
in the appliance warranty form. When buying the appliance the 
warranty form must be filled and signed both by seller and buyer. 
Keep the warranty form in a secure place. 
In all instances shall be in force the applicable laws, regulations 
and  other  legislation  dealing  with  the  rights  and  obligations  of 
consumer, seller and manufacturer, and their relationships related 
to  purchased  water  heater,  its  installation,  use,  servicing  and 
maintenance. 
Warranty term is determined by seller and is in force only for the 
geographical territory of the country.
Warranty is valid only if the appliance:

џ

Is installed according to the requirements for installation and 
operation.

џ

Is used only as per designed purpose and in accordance with 

the installation and operation manual.

Warranty consists of free of charge repair of all factory defects, 
which may arise during the warranty term. Repair is performed by 
service specialists, authorized by seller. 
Warranty is not valid for damages, caused by:

џ

Improper transportation

џ

Improper storage

џ

Improper usage

џ

Parameters of water, different from the admissible norms for 
quality of drinking water, and particularly if the composition of 
chlorides is more than 250 mg/l; the electrical conductivity is 
less  than  100  μS/cm  and  pH  is  outside  of  6,5-8  for  water 
heaters  with  enameled  water  tanks;  the  electrical 
conductivity is more than 200 μS/cm for water heaters with 
water tanks made of chrome-nickel steel.

џ

Supply voltage, different than the unit's rated voltage.

џ

Damages due to freezing of water.

џ

Elemental  perils,  disasters  and  other  force  majeure 
circumstances.

џ

Non observance of the installation and operation manual.

џ

In cases, when a non authorized person has tried to repair 
any kind of a defect. 

In  the  above  cases  the  defect  will  be  repaired  against  relative 
payment.
Warranty shall not apply to normal wear parts and components of 
the  device,  parts  that  are  being  removed  during  normal  use, 
lighting  and  signal  lamps  and  the  like,  changing  the  color  of 
external surfaces, change of shape, size and location of parts and 
components that are exposed to impact and conditions that are not 
considered normal use.
Lost  profits,  tangible  and  intangible  damages  caused  by 
temporary  inability  to  use  the  device  during  its  prevention  and 
repair shall not by covered by the warranty.

COMPLIANCE  WITH  THE  REQUIREMENTS  OF  THIS 
INSTRUCTION  MANUAL  IS  A  PREREQUISITE  FOR  SAFE 
OPERATION OF YOUR PURCHASED PRODUCT AND IS ONE 
OF THE WARRANTY TERMS AND CONDITIONS. 
IT  IS  ABSOLUTELY  PROHIBITED  TO  THE  USER  OR  ANY 
AUTHORIZED  BY  HIM  PERSON  TO  UNDERTAKE  ANY 
CHANGES  IN  THE  PRODUCT DESIGN AND  STRUCTURE. 
ANY  FINDING  OF  SUCH ACTIONS  OR ATTEMPTS  SHALL 
AUTOMATICALLY  RENDER  VOID  ALL  WARRANTY 
LIABILITIES OF SELLER OR PRODUCER. 
IN  CASE  OF  NECESSITY  FOR  SERVICE  SEEK  ONLY 
MANUFACTURER  AUTHORIZED  SERVICE  COMPANIES 
LISTED IN THE ANNEXED FORM. 
THE  MANUFACTURER  PRESERVED  HIS  RIGHT  TO 
STRUCTURAL CHANGES WITHOUT NOTICE WHERE SUCH 
SHALL NOT AFFECT PRODUCT SAFETY.

MANUFACTURED IN EUROPE FOR YGHP WITH ALL UK 
WARRANTY BEING SUPPORTED BY YGHP. 

Summary of Contents for 30

Page 1: ...EN HOUSEHOLD ELECTRIC WATER HEATERS 30 120 designed for wall installation MANUAL FOR INSTALLATION OPERATION AND MAINTENANCE...

Page 2: ...D 1 2 3 4 5 6 7 8 EN RO LED RU NL DE FR 1 2 3 4 5 6 7 8 Wasseranschluss Ablauf Wasser Kombiniertes Ventil Schalter Thermostat Anodentester Elektronischen Steuereinheit LED Entr e de l eau Sortie de l...

Page 3: ...175 D 387 387 387 462 435 462 435 462 435 E 80 80 80 96 85 96 85 96 85 F 410 410 410 484 455 484 455 484 455 50 80 80 100 120 Fig 2 2 3 2 760 1125 835 1005 1170 C 155 155 185 185 185 D 387 387 462 46...

Page 4: ...Ablauf Wasser W rmetauscher I W rmetauscher II Thermostatmuffe Entr e de l eau Sortie de l eau changeur de chaleur I changeur de chaleur II Douille de thermostat Inlaat water Uitlaat water Warmtewiss...

Page 5: ...250 250 250 250 J 450 450 450 450 450 450 630 K 770 780 365 355 L 220 200 80 80 100 120 Fig 7 0 36 0 35 0 35 0 59 D 387 462 462 462 E 80 96 96 96 M 770 415 587 753 C 155 185 185 185 K 223 250 250 250...

Page 6: ...r Signal lamp LED 1 2 3 4 5 6 7 Interrupteur thermique Thermostat Bouton Thermostat Anode Testeur anode LED Temperatuurbegrenzer Thermostaat Schakelaar Verwarmingsunit Anode Anode tester LED Termo ntr...

Page 7: ...vented certified While the units themselves can often be simple to install to comply with UK laws all installers must be unvented certified If you are unsure on how to fit the unit please contact YGHP...

Page 8: ...dandcompetentpersonsinaccordancewiththeirdesign Thewayofuse of such water heater when heating the water in its tank from an alternative electric coolant as well as compliance with safety measures must...

Page 9: ...pipes for cold and hot water of some vertical and horizontal water heaters arelocatedontherightsideofthewall mountedunit B the outlets of cold hot water pipes of horizontal water heatersarelocatedbelo...

Page 10: ...s are shown the distances between the bolts studs for mountingtheunits WARNING The bearing plates of horizontal water heaters must be securely clamped to the premise wall Under the bolts heads nutsons...

Page 11: ...while the water tank is partially or completely emptied of water Do not forget to fill the tank with water before putting it backintooperation WARNING Thecoolantcirculationthroughtheheatexchanger of...

Page 12: ...tes that the water heater is operating and water is heating while when the light is off it indicates that the water has reached adjusted temperature and the heater is switched off You may switch off t...

Page 13: ...ficiency criterion is its arrow deflection When at the time of pressing the tester button the arrow does not divert or is hold at the beginning of the red section you should contact the specialists at...

Page 14: ...hall be in force the applicable laws regulations and other legislation dealing with the rights and obligations of consumer seller and manufacturer and their relationships related to purchased water he...

Reviews: