4.2 Settings on Welding Source Panel
4-13
HW0480311
HW0480311
The following describes how to reset the system.
(1) Press the button
k
"Common PRM Select" during standby status. The 7-segment
LED indicator
c
voltmeter (V) displays "C.00" blinking, and the 7-segment LED indi-
cator
e
"Wire m/min" (WF) displays the parameter value lighting.
(2) Use the button
"+", "-", "L" or "R" to display the parameter "C23".
(3) Press the button
"PRM Set", and the parameter value on the 7-segment LED
indicator
e
"Wire m/min" blinks. Change the setting value of parameter "C23" to
"2004". When the setting value is four digits or more, use the button
"L" to move
the cursor to the 7-segment LED indicator
d
ammeter (A). The indicator
d
amme-
ter (A) displays the number(s) above the forth digit. The system reset will be exe-
cuted at C23=2004.
Wait until "sys rst" starts blinking.
(4) Turn OFF the welding source when "sys rst" is displayed. This is end of the initial-
ization.
(5) Turn ON the power supply and the parameters return to the default setting. Set the
recorded parameters again if necessary.
V
A
Wire m/min
Type
13
V
A
Wire m/min
Type
11
13
V
A
Wire m/min
Type
V
A
Wire m/min
Type
47/129