15.2 Procedure of Welding Current Calibration
15-4
HW0480311
HW0480311
(2) If the 7-segment LED indicators of "A" and "Wire" on the panel blink, the current cal-
ibration 2 is in standby state.
(3) Set the welding current command to be calibrated from the robot controller side, and
perform welding for six seconds or more.
(4) The calibration performs arithmetic operation for the ratio of the welding current
command to the actual welding current value based on the welding current value
after two to six seconds from welding start.
(5) The LED indicator lamp above the "Record" button flashes when the calibration
operation is confirmed.
5.
Confirming the result of calibration 2
(1) Keep pressing the "R" button to confirm the result of current calibration 2.
Set the welding current command value so that the command value of the current calibra-
tion 2 is higher than that of the current calibration 1.
If the welding time is less than six seconds, the LED indicator lamp above the "Record"
button does not flash after welding. Perform welding for a longer time and welding current
calibration again.
V
A
Wire m/min
Type
NOTE
NOTE
V
A
Wire m/min
Type
The display of
7-segment LED
indicator "V"
: Displays the execution of calibration 2.
The display of
7-segment LED
indicator "A"
: Displays the welding current command value at the
execution of calibration 2.
(The value is registered in the C parameter.)
The display of
7-segment LED
indicator "Wire"
: Displays the calculation result of calibration 2.
(The result is registered in the parameter P63.)
(Ratio= welding current command value / actual welding current value
×
100 %)
The example display shown above indicates; The result of calibration 1: 95 %
The welding current command: 250 A