14.2 Procedure of External Resistance Calibration
14-5
HW0480311
HW0480311
2.
Output of current for the resistance measurement
(1) Record the value of parameter C08 in advance since the result of the measurement
is overwritten.
(2) Press the "Record" button for 3 seconds or more.
The constant current is output for measurement of the resistance, and power is sup-
plied to the power cable that is to be an external resistance path.
The conduction lasts for approx. 2 seconds and completes automatically.
After the output, the resistance is measured and its result is stored in the parameter
C08.
Fig. 25 Current Output for Measurement of Resistance
• Do not touch, the power cable, torch, or jig stand while current for the
resistance measurement is being output.
Failure to observe this caution may result in electric shock.
- Press the "Record" button again to stop the current output during conduction, however
the resistance is not measured.
- When cable for resistance measurement or the power cable, etc. is not connected, the
ammeter (7-segment LED indicator for current) displays 0 A. Confirm the connection
path.
- when the contact of the cable for the resistance measurement and the joint of the power
cable is insufficient, wrong resistance might be measured.
Please confirm not uneven to
measurements repeat this operation
2
and
3
times
,
whether to do a certain connection
.
CAUTION
V
A
Wire m/min
Type
Record
20
Gas
Common PRM Select
PRM Select
PRM Set
Weld,Type
File No.1
File No.2
File No.3
User File Select
Power
Warning
Search
L
R
A.W/S
During electric conduction, outputs the
current of approx 300 A without motor
rotation, and displays blinking voltage
or current on the voltmeter or ammeter.
Pressing the "Record" button for approx
three seconds lights the LED indicator above
the "Record" button, and starts electric conduction.
NOTE
108/129