Programming 162
Preset Reference
d1-01
Frequency Reference 1
Reference 1
Setting units are affected by o1-03.
0.00 to
E1-04
Value
0.00Hz
Q
Q
Q
Q
d1-02
Frequency Reference 2
Reference 2
Frequency reference when multi-function input “Multi-step speed
reference 1” is ON. Setting units are affected by o1-03.
0.00Hz
Q
Q
Q
Q
d1-03
Frequency Reference 3
Reference 3
Frequency reference when multi-function input “Multi-step speed
reference 2” is ON. Setting units are affected by o1-03.
0.00Hz
Q
Q
Q
Q
d1-04
Frequency Reference 4
Reference 4
Frequency reference when multi-function input “Multi-step speed
reference 1,2” is ON. Setting units are affected by o1-03.
0.00Hz
Q
Q
Q
Q
d1-05
Frequency Reference 5
Reference 5
Frequency reference when multi-function input “Multi-step speed
reference 3” is ON. Setting units are affected by o1-03.
0.00Hz
A
A
A
A
d1-06
Frequency Reference 6
Reference 6
Frequency reference when multi-function input “Multi-step speed
reference 1,3” is ON. Setting units are affected by o1-03.
0.00Hz
A
A
A
A
d1-07
Frequency Reference 7
Reference 7
Frequency reference when multi-function input “Multi-step speed
reference 2,3” is ON. Setting units are affected by o1-03.
0.00Hz
A
A
A
A
d1-08
Frequency Reference 8
Reference 8
Frequency reference when multi-function input “Multi-step speed
reference 1,2,3” is ON. Setting units are affected by o1-03.
0.00Hz
A
A
A
A
d1-09
Frequency Reference 9
Reference 9
Frequency reference when multi-function input “Multi-step speed
reference 4” is ON. Setting units are affected by o1-03.
0.00Hz
A
A
A
A
d1-10
Frequency Reference 10
Reference 10
Frequency reference when multi-function input “Multi-step speed
reference 1,4” is ON. Setting units are affected by o1-03.
0.00Hz
A
A
A
A
d1-11
Frequency Reference 11
Reference 11
Frequency reference when multi-function input “Multi-step speed
reference 2,4” is ON. Setting units are affected by o1-03.
0.00Hz
A
A
A
A
d1-12
Frequency Reference 12
Reference 12
Frequency reference when multi-function input “Multi-step speed
reference 1,2,4” is ON. Setting units are affected by o1-03.
0.00Hz
A
A
A
A
d1-13
Frequency Reference 13
Reference 13
Frequency reference when multi-function input “Multi-step speed
reference 3,4” is ON. Setting units are affected by o1-03.
0.00Hz
A
A
A
A
d1-14
Frequency Reference 14
Reference 14
Frequency reference when multi-function input “Multi-step speed
reference 1,3,4” is ON. Setting units are affected by o1-03.
0.00Hz
A
A
A
A
d1-15
Frequency Reference 15
Reference 15
Frequency reference when multi-function input “Multi-step speed
reference 2,3,4” is ON. Setting units are affected by o1-03.
0.00Hz
A
A
A
A
d1-16
Frequency Reference 16
Reference 16
Frequency reference when multi-function input “Multi-step speed
reference 1,2,3,4” is ON. Setting units are affected by o1-03.
0.00Hz
A
A
A
A
d1-17
Jog Frequency Reference
Jog Reference
Frequency reference when:
“Jog frequency reference” is selected via multi-function input
terminals. “Jog frequency reference” has priority over “multi-step
speed reference 1 to 4”. d1-17 is also the reference for the JOG key
on the Digital Operator, and the multi-function inputs “forward
jog” and “reverse jog”. Setting units are affected by o1-03.
6.00Hz
Q
Q
Q
Q
Reference Limits
d2-01
Frequency Reference Upper
Limit
Ref Upper Limit
Determines maximum frequency reference, set as a percentage of
maximum output frequency (E1-04). If the frequency reference is
above this value, actual Drive speed will be limited to this value.
This parameter applies to all frequency reference sources.
0.0 to
110.0
100.0%
A
A
A
A
d2-02
Frequency Reference Lower
Limit
Ref Lower Limit
Determines minimum frequency reference, set as a percentage of
maximum output frequency (E1-04). If frequency reference is
below this value, actual Drive speed will be set to this value. This
parameter applies to all frequency reference sources.
0.0 to
110.0
0.0%
A
A
A
A
d2-03
Master Speed Reference
Lower Limit
Ref1 Lower Limit
Determines minimum frequency reference, set as a percentage of
maximum output frequency (E1-04). If frequency reference from
analog input (A1, A2, and A3) is below this value, actual Drive
speed will be set to this value. This parameter applies only to
analog inputs A1, A2, and A3.
0.0 to
110.0
0.0%
A
A
A
A
Denotes that parameter can be changed when the Drive is running.
Table A.1 F7 Parameter List (Continued)
Parameter
No.
Parameter Name
Digital Operator Display
Description
Setting
Range
Factory
Setting
Control Method
V/F
V/F
w/
PG
Open
Loop
Vector
Flux
Vector