Sigma II User’s Manual
Chapter 5: Parameter Settings and Functions
5-53
n
Allocating Other Input Signals
Input signal allocation can be changed as shown below.
Note: *Same as above” means that input signals and terminals SI0 to SI6 are enabled or disabled through
parameter settings 0 to 8.
Input Signal
Parameter
Description
Name
Applicable
Logic
Number
Setting
Proportional Control Reference
(/P-CON)
ON
(low level)
Pn50A.2
0
Inputs the signal on the left from SI0 (CN1-40).
1
Inputs the signal on the left from SI1 (CN1-41).
2
Inputs the signal on the left from SI2 (CN1-42).
3
Inputs the signal on the left from SI3 (CN1-43).
4
Inputs the signal on the left from SI4 (CN1-44).
5
Inputs the signal on the left from SI5 (CN1-45).
6
Inputs the signal on the left from SI6 (CN1-46).
7
Sets the signal on the left to always enabled.
8
Sets the signal on the left to always disabled.
9
Inputs the inverse signal on the left from SI0 (CN1-40).
A
Inputs the inverse signal on the left from SI1 (CN1-41).
B
Inputs the inverse signal on the left from SI2 (CN1-42).
C
Inputs the inverse signal on the left from SI3 (CN1-43).
D
Inputs the inverse signal on the left from SI4 (CN1-44).
E
Inputs the inverse signal on the left from SI5 (CN1-45).
F
Inputs the inverse signal on the left from SI6 (CN1-46).
Forward Run Prohibit
(P-OT)
OFF
(high level)
Pn50A.3
0 to F
Same as above.*
Reverse Run Prohibit
(N-OT)
Pn50B.
0
Alarm Reset
(/ARM-RST)
ON
(low level)
Pn50B.1
Forward Current Limit
(/P-CL)
Pn50B.2
Reverse Current Limit
(/N-CL)
Pn50B.3
Contact Input Speed Control Selection
(/SPD-D)
—
Pn50C.
0
Contact Input Speed Control Selection
(/SPD-A)
Pn50C.1
Contact Input Speed Control Selection
(/SPD-B)
Pn50C.2
Control Mode Selection
(/C-SEL)
ON
(low level)
Pn50C.3
Zero Clamp
(/ZCLAMP)
Pn50D.
0
Reference Pulse Inhibit
(/INHIBIT)
Pn50D.1
Gain Switching
(/G-SEL)
Pn50D.2