10.1 List of Parameters
10-13
10
Ap
pend
ix
Pn217
2
Reserved (Do not change.)
–
–
0
–
–
–
Pn22A
2
Fully-closed Control
Selection Switch
0000 to 1003
−
0000
After restart
Setup
−
Pn281
2
Encoder Output Resolution
1 to 4096
1 edge/
pitch
20
After restart
Setup
8.3.3
Pn300
2
Reserved (Do not change.)
–
–
600
–
–
–
Pn301
2
Reserved (Do not change.)
–
–
100
–
–
–
Pn302
2
Reserved (Do not change.)
–
–
200
–
–
–
Pn303
2
Reserved (Do not change.)
–
–
300
–
–
–
Pn304
2
JOG Speed
0 to 10000
1 min
-1
500
Immediately
Setup
6.3
Pn305
2
Soft Start Acceleration Time
0 to 10000
1 ms
0
Immediately
Setup
–
Pn306
2
Soft Start Deceleration Time
0 to 10000
1 ms
0
Immediately
Setup
–
Pn307
2
Reserved (Do not change.)
–
–
0
–
–
–
Pn310
2
Vibration Detection Switch
0000 to 0002
−
0000
Immediately
Setup
−
Pn311
2
Vibration Detection
Sensibility
50 to 500
1%
100
Immediately
Tuning
6.16
Pn312
2
Vibration Detection Level
0 to 5000
1 min
-1
50
Immediately
Tuning
6.16
Pn324
2
Moment of Inertia Calculating Start Level
0 to 20000
1%
300
Immediately
Setup
5.3.2
Pn400
2
Reserved (Do not change.)
–
–
30
–
–
–
Pn401
2
Torque Reference Filter Time Constant
0 to 65535
0.01 ms
100
Immediately
Tuning
5.9.3
Pn402
2
Forward Torque Limit
0 to 800
1%
800
Immediately
Setup
4.4.1
Pn403
2
Reverse Torque Limit
0 to 800
1%
800
Immediately
Setup
4.4.1
(cont’d)
Parameter
No.
Size
Name
Setting
Range
Units
Factory
Setting
When
Enabled
Classi-
fication
Reference
Section
Reserved (Do not change.)
Reserved (Do not change.)
Reserved (Do not change.)
Speed Feedback Selection at Fully-closed Control
Reference
Section
0
Uses motor encoder speed.
8.3.8
1
Uses external encoder speed.
4th 3rd 2nd 1st
digit digit digit digit
n.
Vibration Detection Selection
Reference
Section
0
Does not detect vibration.
6.16
1
Outputs warning (A.911) when vibration is detected.
2
Outputs alarm (A.520) when vibration is detected.
Reserved (Do not change.)
Reserved (Do not change.)
Reserved (Do not change.)
4th 3rd 2nd 1st
digit digit digit digit
n.