5.8 Additional Adjustment Function
5-61
5
Adjustm
e
nts
5.8.3
Current Control Mode Selection Function
This function reduces high-frequency noises while the servomotor is being stopped. This function is enabled
by default.
5.8.4
Current Gain Level Setting
This function reduces noises by adjusting the parameter value for current control inside the SERVOPACK
according to the speed loop gain (Pn100). The noise level can be reduced by reducing the current gain level
(Pn13D) from its factory setting of 2000% (disabled). If the set value of Pn13D is decreased, the level of noise
will be lowered, but the response characteristics of the SERVOPACK will also be degraded. Adjust the current
gain level within the allowable range at which SERVOPACK response characteristics can be secured.
5.8.5
Speed Detection Method Selection
This function can ensure smooth movement of the servomotor while the servomotor is running. Set the value
of Pn009.2 to 1 and select speed detection 2 to smooth the movement of the servomotor while the servomotor
is running.
5.8.6
Position Integral
The position integral is the integral function of the position loop.
Parameter
Meaning
When Enabled
Classification
Pn009
n.
0
Selects the current control mode 1.
After restart
Tuning
n.
1
[Factory setting]
Selects the current control mode 2 (low noise).
If current control mode 2 is selected, the load ratio may increase while the servomotor is
being stopped.
Pn13D
Current Gain Level
Classification
Setting Range
Setting Unit
Factory Setting
When Enabled
100 to 2000
1%
2000
Immediately
Tuning
If the parameter setting of the current gain level is changed, the responses characteris-
tics of the speed loop will also change. The SERVOPACK might, therefore, be read-
justed again.
Speed
Position
Parameter
Meaning
When Enabled
Classification
Pn009
n. 0
[Factory setting]
Selects speed detection 1.
After restart
Tuning
n. 1
Selects speed detection 2.
If the speed detection method is changed, the response characteristics of the speed loop
will change and the SERVOPACK might be readjusted again.
Pn11F
Position Integral Time Constant
Classification
Setting Range
Setting Unit
Factory Setting
When Enabled
0 to 50000
0.1 ms
0
Immediately
Tuning
Position