6.16 Vibration Detection Level Initialization (Fn01B)
6-27
6
Util
ity Fu
nctions (Fn
)
(3) Related Parameters
The following table lists parameters related to this function and their possibility of being changed while exe-
cuting this function or of being changed automatically after executing this function.
• Parameters related to this function
These are parameters that are used or referenced when executing this function.
• Allowed changes during execution of this function
Yes : Parameters can be changed using S while this function is being executed.
No : Parameters cannot be changed using S while this function is being executed.
• Automatic changes after execution of this function
Yes : Parameter set values are automatically set or adjusted after execution of this function.
No : Parameter set values are not automatically set or adjusted after execution of this function.
2
Press the
Key. The display changes to the Fn01B
execution display.
3
Press the
Key.
"Init" is displayed flashing, and the vibration level is
detected and initialized.
Note: Continues initialization until the
Key is
pressed again.
4
Press the
Key. The display changes from "Init"
to "DONE," for one second and the new setting of
Pn312 becomes enabled.
5
Press the
Key. The display returns to the main
menu of the utility function.
(cont’d)
Step
Display after Operation
Keys
Operation
R U N
V i b r a t i o n D e t e c t
L e v e l I n i t
S t a r t : [ D A T A ]
R e t u r n : [ S E T ]
R U N
V i b r a t i o n D e t e c t
L e v e l I n i t
I n i t
R U N
V i b r a t i o n D e t e c t
L e v e l I n i t
D
㧻 㧺 㧱
R U N
−
F U N C T I O N
−
F n 0 1 4 : O p t I n i t
F n 0 1 B : V i b l v l I n i t
F n 0 1 E : S v M o t O p I D
F n 0 1 F : F B O p M o t I D
Parameter
Name
Mid-execution
changes
Automatic
changes
Pn311
Vibration Detection Sensitivity
Yes
No
Pn312
Vibration Detection Level
No
Yes