13.1 List of Servo Parameters
13.1.2 List of Servo Parameters
13
Parameter Li
s
t
s
13-39
Pn861
2
SVCMD_IO Input Signal
Monitor Allocations 2
0000h to
1717h
–
0000h
All
Immedi-
ately
Setup
*1
Pn862
2
SVCMD_IO Input Signal
Monitor Allocations 3
0000h to
1717h
–
0000h
All
Immedi-
ately
Setup
*1
Pn863
2
SVCMD_IO Input Signal
Monitor Allocations 4
0000h to
1717h
–
0000h
All
Immedi-
ately
Setup
*1
Continued on next page.
Continued from previous page.
Parameter
No.
Size
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
M3
*9
n.
X
Input Signal Monitor Allocation for CN1-8 (SVCMD_IO)
0 to 7
The settings are the same as the CN1-13 allocations.
n.
X
CN1-8 Input Signal Monitor Enable/Disable Selection
0
Disable allocation for CN1-8 input signal monitor.
1
Enable allocation for CN1-8 input signal monitor.
n.
X
Input Signal Monitor Allocation for CN1-9 (SVCMD_IO)
0 to 7
The settings are the same as the CN1-13 allocations.
n.X
CN1-9 Input Signal Monitor Enable/Disable Selection
0
Disable allocation for CN1-9 input signal monitor.
1
Enable allocation for CN1-9 input signal monitor.
M3
*9
n.
X
Input Signal Monitor Allocation for CN1-10 (SVCMD_IO)
0 to 7
The settings are the same as the CN1-13 allocations.
n.
X
CN1-10 Input Signal Monitor Enable/Disable Selection
0
Disable allocation for CN1-10 input signal monitor.
1
Enable allocation for CN1-10 input signal monitor.
n.
X
Input Signal Monitor Allocation for CN1-11 (SVCMD_IO)
0 to 7
The settings are the same as the CN1-13 allocations.
n.X
CN1-11 Input Signal Monitor Enable/Disable Selection
0
Disable allocation for CN1-11 input signal monitor.
1
Enable allocation for CN1-11 input signal monitor.
M3
*9
n.
X
Input Signal Monitor Allocation for CN1-12 (SVCMD_IO)
0 to 7
The settings are the same as the CN1-13 allocations.
n.
X
CN1-12 Input Signal Monitor Enable/Disable Selection
0
Disable allocation for CN1-12 input signal monitor.
1
Enable allocation for CN1-12 input signal monitor.
n.
X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)