1.3 Part Names
1
Ba
s
ic Information on
S
ER
VOP
ACK
s
1-5
No.
Name
Description
Reference
Front Cover
–
–
Input Voltage
–
–
Nameplate
Indicates the SERVOPACK model and ratings.
Model
The model of the SERVOPACK.
QR Code
The QR code that is used by the MechatroCloud service.
–
CHARGE
Lit while the main circuit power is being supplied.
Note: Even if you turn OFF the main circuit power supply, this
indicator will be lit as long as the internal capacitor remains
charged. Do not touch the main circuit or motor terminals
while this indicator is lit. Doing so may result in electric
shock.
–
Main Circuit Terminals
The terminals depend on the main circuit power supply
input specifications of the SERVOPACK.
Servomotor Terminals (U, V,
and W)
The connection terminals for the Servomotor Main Circuit
Cable (power line).
Ground Terminal (
)
The ground terminals to prevent electric shock. Always
connect this terminal.
–
MECHATROLINK-III Com-
munications Connector
(CN6A and CN6B)
Connects to MECHATROLINK-III-compatible devices.
Serial Communications Con-
nector (CN3)
Connects to the Digital Operator (a peripheral device) or a
computer (RS-422).
Computer Connector (CN7)
A USB connector to connect a computer.
Safety Option Module Con-
nector
Connects to a Safety Option Module.
I/O Signal Connector (CN1)
Connects to sequence I/O signals.
Feedback Option Module
Connector
Connects to a Feedback Option Module.
–
Safety Connector (CN8)
Connects to a safety function device.
Encoder Connector (CN2)
•
Rotary Servomotor: Connects to the encoder in the Ser-
vomotor.
•
Linear Servomotor: Connects to a Serial Converter Unit
or linear encoder.
Serial Number
–
–
DIP Switch (S3)
Used to set MECHATROLINK-III communications.
Rotary Switches (S1 and S2) Used to set the MECHATROLINK station address.
PWR
Lights when the control power is being supplied.
–
L1, L2
Lights during MECHATROLINK communications.
–
CN
Lights when the SERVOPACK normally receives a CON-
NECT command.
–
Analog Monitor Connector
(CN5)
You can use a special cable (peripheral device) to monitor
the motor speed, torque reference, or other values.
Panel Display
Displays the servo status with a seven-segment display.
–
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25