6.1 I/O Signal Allocations
6.1.8 /COIN (Positioning Completion) Signal
6-12
6.1.8
/COIN (Positioning Completion) Signal
The /COIN (Positioning Completion) signal indicates that Servomotor positioning has been
completed during position control.
The /COIN signal is output when the difference between the reference position output by the
host controller and the current position of the Servomotor (i.e., the position deviation as given
by the value of the deviation counter) is equal to or less than the setting of the positioning com-
pleted width (Pn522).
Use this signal to check the completion of positioning from the host controller.
Note: You must allocate the /COIN signal to use it. Use Pn50E = n.
X (/COIN (Positioning Completion Output)
Signal Allocation) to allocate the signal to connector pins. Refer to the following section for details on alloca-
tions.
6.1.2 Output Signal Allocations
Setting the Positioning Completed Width
The /COIN signal is output when the difference between the reference position and the current
position (i.e., the position deviation as given by the value of the deviation counter) is equal to or
less than the setting of the positioning completed width (Pn522).
The setting of the positioning completed width has no effect on final positioning accuracy.
Note: If the parameter is set to a value that is too large, the /COIN signal may be output when the position deviation
is low during a low-speed operation. If that occurs, reduce the setting until the signal is no longer output.
Type
Signal
Connector Pin No.
Signal Status
Meaning
Output
/COIN
Must be allocated.
ON (closed)
Positioning has been completed.
OFF (open)
Positioning has not been completed.
Pn522
Positioning Completed Width
Setting Range
Setting Unit
Default Setting
When Enabled
Classification
0 to 1,073,741,824
1 reference unit
7
Immediately
Setup
Position
Pn522
Reference
Motor
s
peed
Time
Time
Time
/COIN
s
ignal
Po
s
ition
deviation
S
peed
(Active when ON (clo
s
ed).)