9.4 Monitoring Product Life
9.4.1 Items That You Can Monitor
9-13
9
Monitoring
9.4
Monitoring Product Life
9.4.1
Items That You Can Monitor
Monitor Item
Description
SERVOPACK Installation Envi-
ronment
The operating status of the SERVOPACK in terms of the installation envi-
ronment is displayed. Implement one or more of the following actions if the
monitor value exceeds 100%.
•
Lower the surrounding temperature.
•
Decrease the load.
Servomotor Installation Environ-
ment
The operating status of the SERVOPACK in terms of the installation envi-
ronment is displayed. Implement one or more of the following actions if the
monitor value exceeds 100%.
•
Lower the surrounding temperature.
•
Decrease the load.
Built-in Fan Service Life Predic-
tion
The unused status of the SERVOPACK is treated as the 100% value. The
value decreases each time the main circuit power supply is turned ON and
each time the servo is turned OFF. Use a monitor value of 0% as a guideline
for the replacement period. Refer to the following section for part replace-
ment guidelines.
12.1.2 Guidelines for Part Replacement
Capacitor Service Life Predic-
tion
The unused status of the SERVOPACK is treated as the 100% value. The
value decreases each time the main circuit power supply is turned ON and
each time the servo is turned OFF. Use a monitor value of 0% as a guideline
for the replacement period. Refer to the following section for part replace-
ment guidelines.
12.1.2 Guidelines for Part Replacement
Surge Prevention Circuit Ser-
vice Life Prediction
The unused status of the SERVOPACK is treated as the 100% value. The
value decreases each time the main circuit power supply is turned ON and
each time the servo is turned OFF. Use a monitor value of 0% as a guideline
for the replacement period. Refer to the following section for part replace-
ment guidelines.
12.1.2 Guidelines for Part Replacement
Dynamic Brake Circuit Service
Life Prediction
The unused status of the SERVOPACK is treated as the 100% value. The
value decreases each time the main circuit power supply is turned ON and
each time the servo is turned OFF. Use a monitor value of 0% as a guideline
for the replacement period. Refer to the following section for part replace-
ment guidelines.