13.1 List of Servo Parameters
13.1.2 List of Servo Parameters
13
Parameter Li
s
t
s
13-9
Pn00F
2
Application Function
Selections F
0000h to
2011h
–
0000h
All
After
restart
Setup
–
Pn021
2
Reserved parameter (Do
not change.)
–
–
0000h
All
–
–
–
Pn022
2
Reserved parameter (Do
not change.)
–
–
0000h
All
–
–
–
Pn040
2
Σ
-V Compatible Func-
tion Switch
0000h to
2111h
–
0000h
–
After
restart
Setup
–
Pn080
2
Application Function
Selections 80
0000h to
1111h
–
0000h
Linear
After
restart
Setup
–
Continued on next page.
Continued from previous page.
Parameter
No.
Size
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
n.
X
Preventative Maintenance Warning Selection
Reference
0
Do not detect preventative maintenance warnings.
1
Detect preventative maintenance warnings.
n.
X
Reserved parameter (Do not change.)
n.
X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)
n.
X
Communications Interface Compatibility Selection
Applicable
Motors
0
Perform
Σ
-7 communications.
All
1
Perform
Σ
-V communications.
n.
X
Encoder Resolution Compatibility Selection
Applicable
Motors
0
Use the encoder resolution of the Servomotor.
Rotary
1
Use a resolution of 20 bits when connected to an SGM7J,
SGM7A, SGM7P, SGM7G, SGM7E, or SGM7F Servomotor.
n.
X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)
n.
X
Polarity Sensor Selection
Reference
0
Use polarity sensor.
1
Do not use polarity sensor.
n.
X
Motor Phase Sequence Selection
Reference
0
Set a phase-A lead as a phase sequence of U, V, and W.
1
Set a phase-B lead as a phase sequence of U, V, and W.
n.
X
Reserved parameter (Do not change.)
n.X
Calculation Method for Maximum Speed or Encoder Output Pulses
Reference
0
Calculate the encoder output pulse setting for a fixed maximum
speed.
1
Calculate the maximum speed for a fixed encoder output pulse
setting.