![YASKAWA S-II Plus Series Instructions Manual Download Page 24](http://html.mh-extra.com/html/yaskawa/s-ii-plus-series/s-ii-plus-series_instructions-manual_907672024.webp)
7 INSTALLATION CONDITIONS OF EMC DIRECTIVE
E - 20
J
Three-phase 200 V, 0.75 kW:
SGDP-08APA (Three-phase 200 V, 0.75 kW)
SERVOPACK
L1, L2, L3
L1C, L2C
CN1
CN2
U, V, W
PE
PE
Power Supply
Clamp
Three-phase
200 VAC
Noise
Filter
Brake Power
Supply
Core
Brake
Servo-
motor
Encoder
Core
Core
Clamp
Clamp
Core
Core
Core
Controller
Ground Plate / Shield Box
Approx. 2 m
(7.87 in)
Approx. 5 m
(19.7 in)
2
3
1
4
Symbol
Cable Name
Specification
1
Controller cable
Shield cable
2
Servomotor cable
Shield cable
3
Encoder cable
Shield cable
4
AC Line cable
Shield cable