4 WIRING
E - 12
4.1
Connecting to Peripheral Devices
J
Single
−
phase Main Circuit (100VAC or 200VAC)
...
R S T
L1 L2
L1C L2C
B1 B2
U V W
YASKAWA
SERVOPACK
MODE/SET
DATA/
CHARGE
POWER
SGDP
−
200V
C
N
3
C
N
1
C
N
2
L1
L2
1
2
L1C
L2C
B1
B2
U
V
W
Molded-case circuit
breaker (MCCB)
Used to protect
power supply line.
Shuts the circuit
OFF if overcurrent
is detected.
Noise filter
Used to eliminate external
noise from power supply
line.
Magnetic contactor
Turns the servo
ON or OFF.
Use a surge
suppressor for
the magnetic
contactor.
Brake power supply
Types:
LPSE-2H01 (for 200 V input)
LPDE-1H01 (for 100 V input)
Regenerative resistor unit
If the capacity of the regenerative resistor is
insufficient, connect the external regenera-
tive resistor unit to the B1-B2 terminals.
Molded-case
circuit breaker
Noise filter
Magnetic
contactor
Magnetic
contactor
Power
ground
Regenerative
resistor (option)
Brake
power supply
Cable and
Connector for
encoder
Allows the user to set
parameters or
operation references
and display operation
status or alarmstatus.
The operator is
communicated with
personal computers.
Digital operator
JUSP-OP02A
−
2
Personal computer
Host controller
SERVOPACK is compatible with most P.L.C.
motion controllers and indexers.
Cable type: JZSP
−
CMS01 TO 03
MEMOCON GL120,GL130 with Motion Module
Power supply
3 phase AC 200V