5 Installation Procedure
YASKAWA ELECTRIC
TOBP C730600 59A V1000 Option Modbus TCP/IP Installation Manual
EN 21
Figure 9
Figure 9 Remove the Terminal Cover on an IP20/NEMA Type 1 Drive
(Models CIMR-V
BA0006F to BA0018F; 2A0008F to 2A0069F;
4A0001F to 4A0038F)
7.
For models CIMR-V
BA0001F to BA0003F, 2A0001F to 2A0006F, loosen the
screws attaching the NEMA Type 1 conduit bracket to the drive to remove the
NEMA Type 1 conduit bracket.
Figure 10
Figure 10 Remove the NEMA Type 1 Conduit Bracket
8.
On NEMA Type 1 enclosure models (CIMR-V
BA0001F to BA0003F, 2A0001F to
2A0006F), the screw for the drive ground terminal also acts as one of the screws
that attaches the NEMA Type 1 conduit bracket to the drive. Reattach the NEMA
Type 1 conduit bracket according to
Figure 11
and connect the drive-side of the
ground wire to the drive ground terminal.
Note:
The four different ground wires packaged with the option connect the option to different drive
models. Select the proper ground wire depending on drive size. Refer to
Table 6
on page
19
for
ground wire selection by drive model.
V1000