VAN-V19001E [V1000→GA500]
15
/35
3-4. Differences in Terminal Size, Shape, and Wire Gauge
Main circuit terminal sizes and wire gauges
The wire gauge sizes for the GA500 described here are different from the connectable wire gauge sizes indicated in the
instruction manual for the purpose of clarifying the compatibility with the V1000.
* For information on the GA500 recommended wire gauge sizes and the wire gauge sizes compliant with the European
standards and the UL standards, refer to the GA500 Technical Manual.
Table 9: Icons representing the screw head shapes
Table 10: Differences in main circuit terminal size and wire gauge for 200 V class Note:
shows an earthing terminal
Model
Drive capacity
V1000: Type
GA500: Type
Terminal
Connectable
wire gauge size:
mm
2
Terminal Screw
Tightening
torque: N-m
(lbf
・
in)
Size
Shape
V1000
2A0001
2A0002
2A0004
2A0006
R/L1, S/L2, T/L3
0.75-2
M3.5
0.8-1.0
(7.1-8.9)
U/T1, V/T2, W/T3
-, +1, +2
B1, B2
⏚
GA500
2001
2002
2004
2006
R/L1, S/L2, T/L3
2
Note: Change the
wiring when
replacing from
V1000.
M3
0.5-0.6
(4.4-5.3)
U/T1, V/T2, W/T3
-, +1, +2
B1, B2
⏚
M3.5
0.8-1.0
(7.1-8.9)
V1000
2A0008
2A0010
2A0012
2A0018
2A0020
R/L1, S/L2, T/L3
2-5.5
M4
1.2 to 1.5
(10.6-13.3)
U/T1, V/T2, W/T3
-, +1, +2
B1, B2
⏚
GA500
2008
2010
2012
R/L1, S/L2, T/L3
2-5.5
M3
0.5-0.6
(4.4-5.3)
U/T1, V/T2, W/T3
-, +1, +2
B1, B2
⏚
M4
1.2 to 1.5
(10.6-13.3)
2018
R/L1, S/L2, T/L3
2-5.5
M4
1.5-1.7
(13.5-15)
U/T1, V/T2, W/T3
-, +1, +2
2-8
B1, B2
2-5.5
⏚
1.2 to 1.5
(10.6-13.3)
2021
R/L1, S/L2, T/L3
2-8
M4
1.5-1.7
(13.5-15)
U/T1, V/T2, W/T3
2-5.5
-, +1, +2
2-8
B1, B2
2-5.5
⏚
1.2-1.5
(10.6-13.3)
V1000
2030
R/L1, S/L2, T/L3
5.5-14
M4
2.1-2.3
(18.6-20.4)
U/T1, V/T2, W/T3
-, +1, +2
B1, B2
2-5.5
⏚
5.5-14
M5
2.0-2.5
(17.7-22.1)
Icon
Screw head shape
Slotted head (-)
Hexagon socket head (width across flats: 5)