n
Three-Phase 200 V Class
Table i.5 Wire Gauge and Torque Specifications (Three-Phase 200 V Class)
Drive Model
Terminal
Recomm. Gauge
AWG, kcmil
Wire Range
AWG, kcmil
Screw
Size
Tightening Torque
N·m (lb.in.)
2A0004
2A0006
2A0008
2A0010
R/L1, S/L2, T/L3
14
14 to 10
M4
1.2 to 1.5
(10.6 to 13.3)
U/T1, V/T2, W/T3
14
14 to 10
⊖
,
⊕
1,
⊕
2
–
14 to 10
B1, B2
–
14 to 10
10
14 to 10
2A0012
R/L1, S/L2, T/L3
12
14 to 10
M4
1.2 to 1.5
(10.6 to 13.3)
U/T1, V/T2, W/T3
14
14 to 10
⊖
,
⊕
1,
⊕
2
–
14 to 10
B1, B2
–
14 to 10
10
14 to 10
2A0018
R/L1, S/L2, T/L3
10
12 to 10
M4
1.2 to 1.5
(10.6 to 13.3)
U/T1, V/T2, W/T3
10
14 to 10
⊖
,
⊕
1,
⊕
2
–
14 to 10
B1, B2
–
14 to 10
10
14 to 10
2A0021
R/L1, S/L2, T/L3
10
12 to 10
M4
1.2 to 1.5
(10.6 to 13.3)
U/T1, V/T2, W/T3
10
12 to 10
⊖
,
⊕
1,
⊕
2
–
12 to 10
B1, B2
–
14 to 10
10
12 to 10
2A0030
R/L1, S/L2, T/L3
8
10 to 6
M4
2.1 to 2.3
(18.6 to 20.4)
U/T1, V/T2, W/T3
8
10 to 6
⊖
,
⊕
1,
⊕
2
–
10 to 6
B1, B2
–
14 to 10
10 to 8
M5
2.0 to 2.5
(17.7 to 22.1)
2A0040
R/L1, S/L2, T/L3
6
8 to 6
M4
2.1 to 2.3
(18.6 to 20.4)
U/T1, V/T2, W/T3
8
8 to 6
⊖
,
⊕
1,
⊕
2
–
6
B1, B2
–
12 to 10
10 to 8
M5
2.0 to 2.5
(17.7 to 22.1)
2A0056
R/L1, S/L2, T/L3
4
6 to 4
M6
5.4 to 6.0
(47.8 to 53.1)
U/T1, V/T2, W/T3
4
6 to 4
⊖
,
⊕
1,
⊕
2
–
6 to 4
B1, B2
–
10 to 6
M5
2.7 to 3.0
(23.9 to 26.6)
6
8 to 6
M6
5.4 to 6.0
(47.8 to 53.1)
2A0069
R/L1, S/L2, T/L3
3
4 to 3
M8
9.9 to 11.0
(87.6 to 97.4)
U/T1, V/T2, W/T3
3
4 to 3
⊖
,
⊕
1,
⊕
2
–
4 to 3
B1, B2
–
8 to 6
M5
2.7 to 3.0
(23.9 to 26.6)
6
6 to 4
M6
5.4 to 6.0
(47.8 to 53.1)