MP/INVERTER/SERVO Ethernet Driver
GP-Pro EX Device/PLC Connection Manual
72
Settings of External Device
Set communication settings for both MP and
-7 Series.
MP Series Setting
Use the ladder software (MPE720) to set up communication settings.
For details on communication settings, please refer to the manual of the External Device.
1
Start the ladder software.
2
Make a project file.
3
From the tree view, double-click [Module Configuration].
[Engineering Manager] starts.
4
In the [Create new file] dialog box, click [OK].
5
In the [Engineering Manager]’s [Controller], use the pull-down menu to select MECHATROLINK connection
module.
Select the number associated with the slot number used by the module.
When you select the MECHATROLINK connection module, its setting information is displayed in the
[Engineering Manger]’s [Module details].
6
In the [module Details]’s [Circuit Number] field, enter "01".
Set up the same value as the Display’s circuit number.
7
In [Details], double-click [MECHATROLINK].
8
Click the [Link Assignments] tab, and then [ST#]’s [01] as follows.
9
In the [Engineering Manager]’s [Controller], select CPU.
10
In the [Module details], double-click the communication module’s No. field.
11
Set [Transmission Parameters] as follows.
12
From the [File] menu select [Save] to save your settings, and exit [Engineering Manager].
13
Write the settings to MP Series.
Setup Items
Setup Description
ADR
03H
ExADR
00
VENDOR
Yaskawa Electric co.
DEVICE
-7 Series type
• [PROFILE], [BYTE] and [SCAN] are defined automatically.
Setup Items
Setup Description
IP Address
192.168.0.1
Subnet Mask
255.255.255.0
• To write the settings, select the [Save to flash after transferring to the controller] check
box.
If the data is transferred without selecting the check box, the transferred data is
deleted when restarting the External Device.