MP/INVERTER/SERVO Ethernet Driver
GP-Pro EX Device/PLC Connection Manual
49
Settings of External Device
Use the ladder software (MP720 Ver.7) to set up communication settings. Set the next contents.
(1) Main CPU settings
(2) MPU-01 settings
(3)
-Vseries settings
For details on communication settings, please refer to the manual of the External Device.
Main CPU Settings
1
Start the ladder software.
2
Make a project file. Select the main CPU models from [Model].
3
From the tree view, double-click [Module Configuration].
[MC-Configurator] starts.
4
Double-click [218IFD] on the CPU to use.
5
Click [Parameters] tab.
6
Set "IP Address" and "Subnet Mask" of "Transmission Parameters".
7
Double-click the module number corresponding to the option slot which attaches MPU-01 in the [MC-
Configurator]
8
Select [MPU-01] in the [Module] dialog box, and click [OK].
9
Set "3" to the circuit number of MPU-01 that displayed in the [MC-Configurator].
Set up the same value as the Display’s circuit number.
10
Write the settings to the External Device.
MPU-01 Settings
1
Start the ladder software.
2
Make a project file. Select "MPU-01" from [Model].
3
From the tree view, double-click [Module Configuration].
[MC-Configurator] starts.
4
Expand [SVC] of [MPU-01] module, and double-click [01 UNDEFINED].
5
Select the using
-V series of [Slave] dialog box, and click [OK].
6
Set "1" to the circuit number of [SVC].
7
Set "3" to the station address of the added V-series.
Setup Items
Setup Description
IP Address
192.168.0.1
Subnet Mask
255.255.255.0
• To write the settings, select the [Save to flash after transferring to the controller] check
box.
If the data is transferred without selecting the check box, the transferred data is
deleted when restarting the External Device.