5.5 One-parameter Tuning (Fn203)
5-51
5
Adjustments
Feedforward
If Pn140 is set to the factory setting and the tuning mode setting is changed to 2 or 3, the feedforward gain
(Pn109), speed feedforward (VFF) input, and torque feedforward (TFF) input will be disabled.
Set Pn140.3 to 1 if model following control is used together with the speed feedforward (VFF) input and
torque feedforward (TFF) input from the host controller.
Refer to
Σ
-V Series User’s Manual MECHATROLINK-II Commands
(Manual No.: SIEP S800000 54) for
details.
Parameter
Function
When Enabled
Classification
Pn140
n.0
[Factory setting]
Model following control is not used together with the
speed/torque feedforward input.
Immediately
Tuning
n.1
Model following control is used together with the
speed/torque feedforward input.
• Model following control is used to make optimum feedforward settings in the SERVO-
PACK when model following control is used with the feedforward function. Therefore,
model following control is not normally used together with either the speed feedfor-
ward (VFF) input or torque feedforward (TFF) input from the host controller. However,
model following control can be used with the speed feedforward (VFF) input or torque
feedforward (TFF) input if required. An improper feedforward input may result in over-
shooting.