Pn810
2
Exponential Function Accel-
eration/Deceleration Bias
0 to 65535
100
reference
unit/s
0
Immedi-
ately
*4
Setup
*1
Pn811
2
Exponential Function Accel-
eration/Deceleration Time
Constant
0 to 5100
0.1 ms
0
Immedi-
ately
*4
Setup
*1
Pn812
2
Movement Average Time
0 to 5100
0.1 ms
0
Immedi-
ately
*4
Setup
*1
Pn814
4
Final Travel Distance for
External Positioning
-1073741823
to
1073741823
1
reference
unit
100
Immediately
Setup
*1
Pn816
2
Homing Mode Setting
–
–
0000
Immediately
Setup
*1
Pn817
*5
2
Homing Approach Speed 1
0 to 65535
100
reference
unit/s
50
Immedi-
ately
*3
Setup
*1
Pn818
*6
2
Homing Approach Speed 2
0 to 65535
100
reference
unit/s
5
Immedi-
ately
*3
Setup
*1
Pn819
4
Final Travel Distance for
Homing
-1073741823
to
1073741823
1
reference
unit
100
Immediately
Setup
*1
∗1.
For details, refer to
Σ
-V Series User’s Manual MECHATROLINK-II Commands
(Manual No.: SIEP S800000 54).
∗3.
Change the setting when the reference is stopped (DEN is set to 1), because the change will affect the output during
operation.
∗4.
The settings are updated only if the sending of the reference has been stopped (DEN is set to 1).
∗5.
The set value of Pn842 is valid when the set value of Pn817 is 0. Software version 0023 or higher is required to use
Pn842.
∗6.
The set value of Pn844 is valid when the set value of Pn818 is 0. Software version 0023 or higher is required to use
Pn844.
(cont’d)
Parameter
No.
Size
Name
Setting
Range
Units
Factory
Setting
When
Enabled
Classification
Reference
Section
4th 3rd 2nd 1st
digit digit digit digit
n.
Software Limit Function
0
Forward
1
Reverse
Reserved (Do not change.)
Reserved (Do not change.)
Reserved (Do not change.)